ISW Horizontal Centrifugal water pump
- Loading Port:
- China Main Port
- Payment Terms:
- TT OR LC
- Min Order Qty:
- -
- Supply Capability:
- -
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
Specifications
ISW series horizontal pipeline centrifugal pump
1.widely use
2.veriety
3.comptitive products and price
4.ISO
ISW series horizontal pipeline centrifugal pump
1, smooth operation: absolute concentricity of pump shaft excellent static and dynamic balance of impeller ensure stable operation, no vibration.
2, watertight: hard alloy seal with different materials to ensure the transportation of different media are no leakage.
3, low noise: two low noise bearing of the water pump, smooth operation, in addition to the motor faint sound, the basic no noise.
4, low failure rate, structure is simple and reasonable, the key part adopts the international first-class quality form a complete set, the trouble-free working time greatly improve.
5, easy maintenance: replace seal and bearing, simple convenient.
6, more space-effective: the outlet is available to the left, right, up three direction, easy for pipeline layout and installation, save a space.
7, ISW horizontal fresh water pump for conveying water and physical and chemical properties of YuQingShui similar other liquid and suitable for industrial and urban water supply, pressurized water supply in high-rise constructions, garden sprinkler irrigation, fire booster, distant distance transportation, hvac refrigeration cycle, such as the bathroom, cold and hot water circulation pressurization and equipment accessories, using temperature T acuities were 80 °C.
8, ISWR horizontal hot water pump are widely used in metallurgy, chemical industry, textile, papermaking, and hotels etc boiler hot water booster cycle transport and urban heating system, ISWR type using temperature T 120 °C or less.
9, ISWH horizontal chemical pump, for delivery not containing solid particles, and viscosity similar to corrosive liquid water, used in petroleum, chemical, metallurgy, electric power, papermaking, food, pharmacy and synthetic fibre and other departments, the use of temperature from °C ~ + 120 °C.
10, ISWB horizontal pipeline oil pump for transport gasoline, kerosene, diesel oil and other oil products or flammable, late detonation liquid, by conveying medium temperature of 20 °C ~ + - 120 °C
- Q: What are the internal losses in centrifugal pumps? How did they come about?
- Hydraulic loss: the loss of water by friction, eddy, impact, etc in a flow;
- Q: What is the pump lift voltage? And how to suppress the pumping voltage rise?
- [suppression of pumping voltage] the general use of the installation of absorption resistance to absorb the pump voltage rise. The simplest way to control the pump voltage is to connect the DC bus with an energy consumption resistor before releasing the pump voltage.
- Q: What is the Rhodes pump?
- The ultimate vacuum of roots pump depends on the pump structure and manufacturing accuracy, and also depends on the limit vacuum of the front pump. In order to increase the limit vacuum of the pump, the roots pump can be used in series. The working principle of roots pump is similar to roots blower. As the rotor continues to rotate, the gas is pumped from the intake air to the space between the rotor and the pump housing V0, and then discharged through the exhaust port. Since the V0 space is fully enclosed after inhalation, the gas in the pump cavity does not compress and expand. But when the top of the rotor turns off the edge of the exhaust and the V0 space communicates with the exhaust side, the gas pressure at the exhaust side is higher, and a part of the gas flows back into the space V0, causing a sudden increase in the gas pressure. As the rotor continues to rotate, the gas is expelled from the pump. Roots pump in the pump cavity, there are two "8" shape of the rotor perpendicular to each other on a pair of parallel axis, by a transmission ratio of 1 of a pair of gear belt movements synchronous reverse movement of each other. In the rotor, the rotor and the pump housing between the wall to maintain a certain gap, you can achieve high speed operation.
- Q: What are the characteristics of a pipe shield pump?
- Four, high melting point in the pump hydraulic side and the motor side with a jacket, the jacket can be steam or a certain temperature of liquid to prevent high melting liquid crystallization. The outer circulation pipe of the pump should also be insulated (heating) jacket. Five, high pressure shielding pump shell is a high pressure container, so that the pump can withstand high system pressure. In order to support the shield under internal high pressure, the stator coil itself can be used to bear the pressure. Can also be made in high temperature and high pressure under the operation of the canned pump. Six, since the suction port of the pump impeller center is much higher than that in stopping the pump, when inhaled NO liquid in the tube, the impeller and the increase of the pump chamber is filled with liquid, and then start without irrigation, the pump can work. Self-priming pumps are especially suited for extracting liquids from underground containers. In addition, according to different methods can be divided into liquid type, mud type, high pressure pipeline type, as well as for ships, nuclear power plants and absorption refrigeration devices for various types of canned pumps. Can also be divided into vertical, horizontal, online and single-stage, multi-level and other different types.
- Q: How to install, operate and maintain the pipeline booster pump?
- Should be "People's Republic of China network security law" requirements, since June 1, 2017, the use of Internet services to carry out real name authentication account. In order to ensure your Baidu account can be used normally, please check the account number as soon as possible. Thank you for your understanding and support.How to install, operate and maintain the pipeline booster pump?Brother Yao s Gc76 2547 | browseRecommended for 2016-12-01 23:52:54 best answerThe installation of booster pump must be installed horizontally or vertically according to the installation method. The direction of flow shall be consistent with the arrow on the pump body, and installed as far away from the water level as possible. A valve shall be installed on the pump inlet line for ease of use and maintenance. When the impeller is the aspiration level below the pump on the pump shaft end or around the pump should be installed check valve, the outlet is connected with 13 links for water use, at first use to pump should be filled with water, and tighten the screw plug. The pipe connection should be tight, especially the water inlet pipe can not leak, otherwise it will reduce the pump head or not pumping water. The pump cavity is not water, not a long time running, so as not to damage the seal
- Q: What are the application areas of pumps?
- 1, urban water supply 2, sewage system 3, civil and construction systems 4, agricultural water conservancy system 5, power station system6. Chemical system 7, petroleum industry system 8, mine metallurgy system 9, light industry system 10, ship system
- Q: What is the pump delivery? What's the difference between years and years?
- First of all, as a student majoring in insurance, I strongly condemn the first floor of ignoring practice and trampling on real knowledge!!The insurance industry criticized a lot, but it is required for many people, we should face and try to maintain the healthy development of the industry, the first floor of the insurance you have not done, have no contact with the insurance, insurance, not to dictate the nonsense, more should not be here misleading!
- Q: What is the function of the heating pump system for the water pump design?
- As the feed water temperature is higher, before starting, if not enough to warm the pump, the pump body temperature is uneven, there is a hot, cool phenomenon. The upper part is inflated and the lower part is inflated"
- Q: Does the control cabinet of the fire control pump need to be related to the fire control room?
- Automatic sprinkler, which is mostly used in this device or high water tank, the whole set of equipment must meet the most unfavorable point (the farthest the highest point of water) water pressure of the faucet.
- Q: Why is the submersible pump tripped on an electrical switch?There is no electrical leakage protection, directly connected to the circuit breaker, and when the switch on, the circuit breaker jumpedI checked the line is good, the pump did not break down, is not the water pump?
- There should be the following reasons: 1) the setting value of the trip switch is too small, and the operating current of the submersible pump exceeds its setting value, and the switch is tripped