• Gate Valve with Good Price and High Quality System 1
  • Gate Valve with Good Price and High Quality System 2
  • Gate Valve with Good Price and High Quality System 3
Gate Valve with Good Price and High Quality

Gate Valve with Good Price and High Quality

Ref Price:
get latest price
Loading Port:
Tianjin
Payment Terms:
TT OR LC
Min Order Qty:
100 pc
Supply Capability:
10000 pc/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

 1.Structure of Gate Valve Description

A gate valve, also known as a sluice valve, is a valve that opens by lifting a round or rectangular gate/wedge out of the path of the fluid. The distinct feature of a gate valve is the sealing surfaces between the gate and seats are planar, so gate valves are often used when a straight-line flow of fluid and minimum restriction is desired. The gate faces can form a wedge shape or they can be parallel. Gate valves are primarily used to permit or prevent the flow of liquids, but typical gate valves shouldn't be used for regulating flow, unless they are specifically designed for that purpose. Because of their ability to cut through liquids, gate valves are often used in the petroleum industry. For extremely thick fluids, a specialty valve often known as a knife valve is used to cut through the liquid. On opening the gate valve, the flow path is enlarged in a highly nonlinear manner with respect to percent of opening. This means that flow rate does not change evenly with stem travel. Also, a partially open gate disk tends to vibrate from the fluid flow. Most of the flow change occurs near shutoff with a relatively high fluid velocity causing disk and seat wear and eventual leakage if used to regulate flow. Typical gate valves are designed to be fully opened or closed.When fully open, the typical gate valve has no obstruction in the flow path, resulting in very low friction loss. 

2. Main Features of the Gate Valve

• Valve body cavity using non-toxic epoxy resin,both inside and outside flashboard completely is coated with rubber

•  Free of water pollution

• High manufacturing accuracy

• High strength

• Environmental protection and energy saving

• Good visual effect

 3. Images

 

Gate Valve with Good Price and High Quality

Gate Valve with Good Price and High Quality

4. Gate valve Specification

Gate Valve with Good Price and High Quality

Gate Valve with Good Price and High Quality

 5.FAQ

1. What's are the characteristics of gate valve?

The distinct feature of a gate valve is the sealing surfaces between the gate and seats are planar, so gate valves are often used when a straight-line flow of fluid and minimum restriction is desired. The gate faces can form a wedge shape or they can be parallel. 

2. What is the work principle of gate valve

 The gate faces can form a wedge shape or they can be parallel. Gate valves are primarily used to permit or prevent the flow of liquids, but typical gate valves shouldn't be used for regulating flow, unless they are specifically designed for that purpose. Because of their ability to cut through liquids, gate valves are often used in the petroleum industry. 

3.  What is the structure?

Bonnets provide leakproof closure for the valve body. Gate valves may have a screw-in, union, or bolted bonnet. Screw-in bonnet is the simplest, offering a durable, pressure-tight seal. Union bonnet is suitable for applications requiring frequent inspection and cleaning. It also gives the body added strength. Bolted bonnet is used for larger valves and higher pressure applications.

 

Q: What do you mean by "2" and "200 CF8M"?
CF8M is stainless steel, and 2 is caliber 50200 and should also be bore
Q: What is the difference between the copper gate valve and the ordinary material gate valve?!
The material of general gate valve is cast iron, and the copper gate valve should be used in special requirement.
Q: What is the soft seal gate valve?
Cautions for installation and maintenance of soft sealing gate valve:For double gate valves, the direction of installation shall be in the vertical position of the valve stem, and the handwheel at the top.The installation of the soft gate valve shall be carried out in strict accordance with the installation environment, installation conditions and installation procedures on the factory manual.After installation, the soft seal gate shall be periodically checked for performance and killed in the cradle before any undesirable conditions occur.
Q: Does the tap belong to a stop valve or a gate valve?
When the valve is installed, the medium can enter from the bottom of the valve core and enter the two way from the top. Medium from the spool into the advantages of the valve closed when the packing is not under pressure, can extend the service life of the packing, and can be pressure in front of the valve in the case of replacement of packing work. Medium from the spool into the bottom of the shortcomings of the valve driving torque is larger, about 1.05~1.08 times above the entrance, the stem by the axial force of large, easy to bend the stem. To this end, the media from below to enter the way, generally only applicable to small caliber manual stop valve, to the valve closed, the media acting on the spool of force is not greater than 350kg limit. Electric cut-off valve is generally used to enter the media from the top way. The disadvantage of the medium entering from the top is just the opposite of the way it is entered below.Compared with the gate valve, the utility model has the advantages of simple structure, good sealing performance, and convenient manufacture and maintenance. The disadvantage is that the liquid resistance is large, and the opening and closing force is large. Gate and globe valves are fully open closed type valve, cut off or connected as the medium use, not as a control valve.The range of application of stop valves and gate valves is determined by their characteristics. In the smaller passages, the cut-off valve is used when required for better shutoff; in the steam pipe and the large diameter water supply pipe, the gate valve is generally used because of less fluid resistance.
Q: What's the difference between the knife gate valve and the stop valve?
Standard light valve professionals to answer for you, gate valve refers to the closure of parts (gate) along the central line of the vertical direction of moving valve. The gate valve is mainly used for cutting in the pipeline. The valve is a valve with a very wide, cutting device general caliber DN = 50mm use it, sometimes a small diameter cutting device also use valve, gate valve has the following advantages:Fluid resistance is small.
Q: What kind of valve is gate valve? Is it different from the cut-off valve?
Gate valve is applied to the big diameter pipeline valve, the valve is generally used in small pipe diameter pipeline, their internal structure is different, the valve can not regulate the flow of water, the valve can be. If you want to understand in detail, it is recommended to take a sample of valve manufacturers to see the internal structure.
Q: What is the difference between the cut-off valve and the gate valve?
When opening and closing, the valve core and valve seat sealing surface always contact and rub each other, so the sealing surface is easy to wear, the valve is close to shut down, the pressure difference between the pipe is very large, so that the sealing surface wear more serious.Gate valve and stop valve advantages and disadvantages:Valve is the advantages of small flow resistance, the media can flow in two directions, but there are tall, complex structure, sealing surface easy to wear shortcomings. The flow resistance of the gate valve is 3-5 times that of the gate valve. Open and close to shut down in order to seal the valve, the valve is completely closed when in contact with the sealing surface, the sealing surface wear is very small, because the flow of the main actuator with large valve should pay attention to adjust the torque control mechanism.
Q: Acid resistant alkali valve gate valve
D is small in shape and beautiful in appearance.E operation is simple and labor-saving.
Q: What are the standards for the execution of cast iron dark pole gate valves?
Four, summary:1, cast iron gate valve is mainly used as a connection and cut off the role of medium. The opening and closing parts of the valve are ram, and the direction of movement of the gate is perpendicular to the direction of flow of the medium. Cast iron gate valve with ductile iron as the main material, the weight is very light, only about 20%~30% of the traditional gate valve;2, cast iron hidden rod gate valve belongs to the class of products, but also the successor to the traditional gate valve, the use of gate generated by the deformation of the compensation role, so that the valve to achieve good sealing effect. Cast iron dark rod valve with open and close the advantages of convenient, reliable sealing, good elastic memory, long service life, can be widely used in metallurgy, electricity, sewage, medicine, construction, food, textile, tap water, energy and other pipeline regulation and closure devices as.
Q: The legend of gate valve and stop valve
The working principle is different. The stop valve is an upward stem type, and the handwheel rotates and rises with the stem. Valve is hand wheel rotation, stem upward movement. Flow is not the same, the gate valve requires full open, the cut-off valve is not the same. The gate valve has no inlet and outlet direction requirements, and the cut-off valve has the required inlet and outlet!Gate valve and stop valve are shut-off valve, is the most common two valves.From the exterior, the gate valve is shorter than the cut-off valve, especially the bar valve needs a higher height space. Valve sealing surface has a certain degree of self sealing capacity, its spool depends on the media pressure tight contact with the valve seat sealing surface, to achieve tight leakage. Wedge gate valve spool angle is generally 3~6 degrees, when forced to shut down excessive or temperature changes of the valve core is easy to die. Therefore, high temperature and high pressure wedge gate valve, in the structure have taken certain measures to prevent spool stuck. The valve in the opening and closing valve and valve seat sealing surface contact and mutual friction is always so easy to wear sealing surface, especially in close off the valve, the valve before and after the great pressure, sealing surface wear is more serious.

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

Hot products


Hot Searches