• Gate Valve Non-rising BS5163 for Whole Sales System 1
  • Gate Valve Non-rising BS5163 for Whole Sales System 2
  • Gate Valve Non-rising BS5163 for Whole Sales System 3
Gate Valve Non-rising BS5163 for Whole Sales

Gate Valve Non-rising BS5163 for Whole Sales

Ref Price:
get latest price
Loading Port:
Tianjin
Payment Terms:
TT OR LC
Min Order Qty:
50 pc
Supply Capability:
5000 pc/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

1.Structure of Gate Valve Description

A gate valve, also known as a sluice valve, is a valve that opens by lifting a round or rectangular gate/wedge out of the path of the fluid. The distinct feature of a gate valve is the sealing surfaces between the gate and seats are planar, so gate valves are often used when a straight-line flow of fluid and minimum restriction is desired. The gate faces can form a wedge shape or they can be parallel. Gate valves are primarily used to permit or prevent the flow of liquids, but typical gate valves shouldn't be used for regulating flow, unless they are specifically designed for that purpose. Because of their ability to cut through liquids, gate valves are often used in the petroleum industry. For extremely thick fluids, a specialty valve often known as a knife valve is used to cut through the liquid. On opening the gate valve, the flow path is enlarged in a highly nonlinear manner with respect to percent of opening. This means that flow rate does not change evenly with stem travel. Also, a partially open gate disk tends to vibrate from the fluid flow. Most of the flow change occurs near shutoff with a relatively high fluid velocity causing disk and seat wear and eventual leakage if used to regulate flow. Typical gate valves are designed to be fully opened or closed.When fully open, the typical gate valve has no obstruction in the flow path, resulting in very low friction loss.

 

2. Main Features of the Gate Valve

• Valve body cavity using non-toxic epoxy resin,both inside and outside flashboard completely is coated with rubber

•  Free of water pollution

• High manufacturing accuracy

• High strength

• Environmental protection and energy saving

• Good visual effect

 

3. Images

 

Gate Valve Non-rising BS5163 for Whole Sales

Gate Valve Non-rising BS5163 for Whole Sales


4. Gate valve Specification

 Gate Valve Non-rising BS5163 for Whole Sales

5.FAQ

1. What's are the characteristics of gate valve?

The distinct feature of a gate valve is the sealing surfaces between the gate and seats are planar, so gate valves are often used when a straight-line flow of fluid and minimum restriction is desired. The gate faces can form a wedge shape or they can be parallel. 

2. What is the work principle of gate valve

 The gate faces can form a wedge shape or they can be parallel. Gate valves are primarily used to permit or prevent the flow of liquids, but typical gate valves shouldn't be used for regulating flow, unless they are specifically designed for that purpose. Because of their ability to cut through liquids, gate valves are often used in the petroleum industry. 

3.  What is the structure?

Bonnets provide leakproof closure for the valve body. Gate valves may have a screw-in, union, or bolted bonnet. Screw-in bonnet is the simplest, offering a durable, pressure-tight seal. Union bonnet is suitable for applications requiring frequent inspection and cleaning. It also gives the body added strength. Bolted bonnet is used for larger valves and higher pressure applications.


Q: Gate valve, butterfly valve, ball valve advantages and disadvantages? What are the usual valves?
Commonly used valves are: gate valve, globe valve, check valve, ball valve, butterfly valve, safety valve, regulating valve, plug valve and so onValve: valve is closed parts (RAM) vertical movement of the valve in the pipeline along the channel axis, used primarily as a medium cut that open and close use. In general, the valve can not be used as a regulation flow. The utility model can be applied to low temperature pressure, and can also be applied to high temperature and high pressure, and can be made according to different materials of the valve. But the valve is generally not used to transport mud and other media pipeline.Advantages: fluid resistance is small; the opening and closing torque needed by the smaller; can use the ring pipe flow to the two direction in the medium, that is to say the unrestricted flow of medium; the fully open, the sealing surface by the erosion of the working medium is smaller than the cut-off valve; the body has the advantages of simple structure, manufacturing good craft; the structure of relatively short length.Disadvantages: the size and height on the larger required installation space is larger; in the process of opening and closing, a relative friction sealing, friction is large, even scratch phenomenon caused by easily at high temperature; the valve has two sealing surface, to processing, polishing and maintenance of some increase the opening and closing time difficult.
Q: What is gate valve (with force transfer joint)?
Double flange loose dowel joint is composed of telescopic joint and pipe flange, screw force transmission component, it can transfer the pressure thrust of the connecting piece (blind plate force) and error compensation line, cannot absorb axial displacement. Broad water supply, I hope to help you!
Q: What kind of gate valve is Z6CS-H102?
Z== valve type: gate valve6== pressure rating: 800LB, API602C== structure: bolt connection, valve cover, bolt connection gland, bright rod support typeS== connection form: socket welding, that is, SWH1== body material: A10502== inner material: seat sealing surface STL, gate sealing surface STL, valve stem 13Cr
Q: greater than DN50 of the pipeline butterfly valve?
I don't know why it was designed. Provide you with some information you refer to, I do not know if it works for you1, stop valve and gate valve are very expensive, more than DN50 can make a lot of money2, butterfly valve is only more than DN50, no small, there may be, but I almost can not see the market.3, like DN150, DN200 such cut-off valve, gate valve is very large, and the butterfly valve is relatively light, installation can save the cost of the block, the valve itself saves too much money.4, but most of the butterfly valve used for a long time are closed.
Q: What is the standard for ductile iron gate valve set?
Clear shot valve installation, is still under way of connection and specifications set "water supply and drainage, heating, gas engineering" or "industrial engineering" pipeline register quota corresponding specifications and installation methods of connecting the valve installed valve section.
Q: What is the meaning of socket welding gate valve A105, D&S:STLT, STEM:13Cr, CL800, SW, AP1602, BB-BG-OS&Y?
Body material: A105Sealing surface material: STLStem material: 13CrPressure rating: CL800Connection: SWImplementation criteria: AP1602BB-BG-OS&Y: plain rod support, bolt connection, flange valve cap.
Q: What does the gate valve 150# mean? Is it stress PN? What's that, PN16 or?It's better to have some specific links, thanks!
150Lb (American Standard pressure value corresponding to the PN2.0)
Q: Will the water supply and drainage to wear civil air defense gate valve, the use of bright rod or dark rod?
3, soft sealing rubber lining valve plate size uniform, interchangeable. Therefore, the soft sealing gate valve will be the direction of development, but also the water supply industry is willing to adopt a valve.
Q: What is the difference between the cut-off valve and the gate valve?
Selection of stop valve:There are two ways to install the valve, one is the media flow from the top of the spool, the advantage is that when the packing is not under pressure, the pressure can be replaced before the valve packing, there is a long service life characteristics. Another is the media from the bottom of the spool into, and its shortcomings are driving torque is large, is 1 times above the flow, the stem by the axial force of large, easy to bend the stem. Generally suitable for small caliber manual stop valve, to stop the valve closed, the media acting on the spool of force is not greater than 350kg limit. Electric cut-off valve is generally used to enter the media from the top way.Selection of gate valve and stop valve:Valve than the valve structure is simple, better sealing, manufacturing and maintenance to be convenient; shortcomings are fluid resistance, power, and opening and closing efforts. Gate valve, stop valve are fully open, fully closed valve, suitable for making cut off, it is not suitable for use as regulating valve. The application process should pay attention to the characteristics of the valve when selecting. Small pipes and better sealing performance generally use cut-off valve; in the steam system and large diameter pipeline, due to fluid resistance is small, suitable for use gate valve.
Q: Gate valve z41t what does that mean?
According to the provisions of the JB/T 308-2004 valve type programming method:Z = gate valve4 = connection form: flangeT = sealing surface material: copper alloy

Send your message to us