• Cast Iron Gate Valve Standard or Nonstandard: Standard Structure: Gate Pressure: Medium System 1
  • Cast Iron Gate Valve Standard or Nonstandard: Standard Structure: Gate Pressure: Medium System 2
Cast Iron Gate Valve Standard or Nonstandard: Standard Structure: Gate Pressure: Medium

Cast Iron Gate Valve Standard or Nonstandard: Standard Structure: Gate Pressure: Medium

Ref Price:
get latest price
Loading Port:
Tianjin
Payment Terms:
TT or LC
Min Order Qty:
100 pc
Supply Capability:
9999 pc/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

Valve is a opening and closing the gate assembly, perpendicular to the direction of movement and direction of flow of the gate, gate valve can be fully open and fully closed, discomfort door parameter varies, usually 5 degrees, the medium temperature is not high for 2 ~ 52 '. Improve the process, make up the sealing surface angle in the process of the deviation, which is called the gate.

Motion editing valve closed, the sealing surface can only rely on media pressure to seal, which only rely on media Z41h flange wedge gate valve pressure on the sealing surface of the disc to the other side of the valve seat to ensure the sealing surface, which is self sealing.

Most of the valve is forced to seal, that is, when the valve is closed, to rely on external force to force the gate to the seat, in order to ensure the sealing surface of the seal.

 

Movement: gate valve with the valve stem together for a straight line movement, also known as the gate valve.

Usually on the lifting rod with trapezoidal thread, through the valve on the top of the nut and the body of the guide slot, the rotating motion into a linear motion, that is, the operating torque into the operating thrust.

When the valve is opened, when the gate height is equal to 1:1 times the diameter of the valve, the fluid passage is completely free, but at the time of operation, the position can not be monitored.

Actual use, is the apex of the stem as a sign, that is, the open position, as its fully open position. In order to consider temperature changes occur locked phenomenon, usually open to the vertex position, and then rewind 1 / 2-1 circle, as a fully open valve position.

 Therefore, the valve fully open position, according to the location of the gate (that is, the stroke.

Some gate valve stem nut is located on the gate, the hand wheel rotation to drive the valve stem rotation, and so that the gate to upgrade, this valve is called the rotating rod gate valve or called the dark bar gate valve.

 

Specifications

Resilient Seated Flanged gate valve 

resilient gate valve F5

1.size:DN40-DN300 

2.medium:water 

3.certificate:ISO9001 CE 

4.standard:DIN

 

WZLD OEM Certificate 2'',12 Inch,16 Inch Cast Iron Manual Gate And Globe Valve


Available medium:water 

Working temperature:≤80°C

Flange dimensions:DIN2501

Face to face dimensions:DIN3202F5

 

cast iron gate valve

cast iron gate valve

Q: What is the soft seal gate valve?
General soft sealing gate valve model is Z41X Ming bar. The dark pole is Z45X. They're all for hydraulic purposes
Q: Which is more expensive, bronze gate valve or brass gate valve?
The casting and workability of brass are much better than that of stainless steel, especially the valve with more complicated internal cavity.
Q: Does the tap belong to a stop valve or a gate valve?
If it is about to pull open and close, it is cock valveIf it is rotated up and down, it is a stop valve
Q: Will the water supply and drainage to wear civil air defense gate valve, the use of bright rod or dark rod?
3, soft sealing rubber lining valve plate size uniform, interchangeable. Therefore, the soft sealing gate valve will be the direction of development, but also the water supply industry is willing to adopt a valve.
Q: What is the allowable leakage rate of the gate valve D?
In GB/T 13927, the leakage rate of the valve is divided into 10 grades, namely: A, AA, B, C, CC, D, E, EE, F, G class. And stipulates that when the order contract does not specify, the metal sealing valve according to D requirements.
Q: What does valve qz45x - 10q mean?
Crown valve pressWhat does Q stand for? I'm not sure. It's probably made of ductile iron"Z" means "gate valve"4 represents flange connection5 represents the dark bar (1 represents the Ming pole)X stands for rubber seal and soft seal10q stands for 10 pressure
Q: What's the meaning of flexible z45x-10q door valve?
Crown valve pressModel Z45X-10QZ refers to gate valve4 finger flange connection5 refers to the dark bar driveX refers to rubber seals10 refers to 10 kg pressureQ refers to the body material, ductile ironFull bore flange soft sealed gate valve
Q: Gate valve is gate valve, gate valve specifications, model code is generally what?
Valve lock plate valve, gate valve and code.According to domestic valve model standards, the valve model is by the valve type, gate valve drive mode, gate valve connection, gate valve structure, sealing material, valve body material code to indicate.1, gate valve type code named Z;2, gate valve drive mode code by letters, common 2- electric hydraulic, 9- electric, 6- pneumatic, 5- bevel gear drive, 3- turbo worm; manual do not need to write out;3, gate valve connection form code with letters to indicate, 1- internal thread, 2- external thread, 4- flange type, 6- welding, 7- pairs clamp type, 9- clamp, 0- card sleeve;4, the valve structure of code, 0- flexible wedge, 1- rod single wedge gate valve, 2- rising stem wedge gate valve, 3- parallel single gate valve, 4- parallel double gate valve, 5- dark pole single wedge gate valve, 6- dark bar wedge gate valve 7-, dark bar parallel gate valve, parallel gate valve 9- dark bar;5, sealing materials or lining materials were used R- T- austenitic stainless steel, copper alloy, X- rubber, S- plastic, N- nylon, F- fluorine plastic, H-Cr series stainless steel, hard alloy Y-, J- rubber, M- Monel alloy, Tc- ceramics;6, the body material code Z- K- gray cast iron, malleable cast iron, Q- ductile iron, copper and T- alloy, C- steel, P- chromium nickel stainless steel, R- stainless steel chromium nickel molybdenum, chromium molybdenum vanadium steel V-.For example: electric, flanged, rod wedge gate valve, sealing surface material by direct processing, nominal pressure PN0.1MPa of the valve body is made of grey cast iron gate valve: Z942W-1 electric wedge gate valve.
Q: Why does the centrifugal pump start and stop in the case of closing the gate valve?
The centrifugal pump starts and stops in the case of closing the pump outlet valve. Start off the pump outlet valve is to reduce the starting current, stop when the pump is closed, the outlet valve is to reduce water hammer, prevent blade from bad.
Q: The legend of gate valve and stop valve
When the valve is installed, the medium can enter from the bottom of the valve core and enter the two way from the top. Medium from the spool into the advantages of the valve closed when the packing is not under pressure, can extend the service life of the packing, and can be pressure in front of the valve in the case of replacement of packing work. Medium from the spool into the bottom of the shortcomings of the valve driving torque is larger, about 1.05~1.08 times above the entrance, the stem by the axial force of large, easy to bend the stem. To this end, the media from below to enter the way, generally only applicable to small caliber manual stop valve, to the valve closed, the media acting on the spool of force is not greater than 350kg limit. Electric cut-off valve is generally used to enter the media from the top way. The disadvantage of the medium entering from the top is just the opposite of the way it is entered below.Compared with the gate valve, the utility model has the advantages of simple structure, good sealing performance, and convenient manufacture and maintenance. The disadvantage is that the liquid resistance is large, and the opening and closing force is large. Gate and globe valves are fully open closed type valve, cut off or connected as the medium use, not as a control valve.The range of application of stop valves and gate valves is determined by their characteristics. In the smaller passages, the cut-off valve is used when required for better shutoff; in the steam pipe and the large diameter water supply pipe, the gate valve is generally used because of less fluid resistance.

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

Hot products


Hot Searches

Related keywords