• Gate Valve Ductile Iron Rising Stem Resilient Seated System 1
  • Gate Valve Ductile Iron Rising Stem Resilient Seated System 2
Gate Valve Ductile Iron Rising Stem Resilient Seated

Gate Valve Ductile Iron Rising Stem Resilient Seated

Ref Price:
get latest price
Loading Port:
Tianjin
Payment Terms:
TT OR LC
Min Order Qty:
200 m.t.
Supply Capability:
10000 m.t./month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

Specification

Material:
Cast Iron
Pressure:
High Pressure
Temperature of Media:
Normal Temperature
Power:
Manual
Media:
Water
OD(Outer Diameter: inch):
400
Size(inch):
DN300
Pressure(LB):
400
Net Weight (kg):
177

1.Structure of Gate Valve Description:
Gate valves are primarily used to permit or prevent the flow of liquids, but typical gate valves shouldn't be used for regulating flow, unless they are specifically designed for that purpose. Because of their ability to cut through liquids, gate valves are often used in the petroleum industry. For extremely thick fluids, a specialty valve often known as a knife valve is used to cut through the liquid.This means that flow rate does not change evenly with stem travel. Also, a partially open gate disk tends to vibrate from the fluid flow.

2.Main Features of the Gate Valve:
The sealing surface of valve seat and gate is overlaid (surfaced) with hard alloy, resistant to corrosion and abrasion.
Valve seat, gate and stem are sealed with imported lip-shaped combined seal structure, so they are safe and reliable, and the switching torque of valves is low.
Simple and safe design of valve gate and seat, makes it easy to change without special tools.
Non-rubber seal effectively protects valve chamber from mud, sand and rock, etc.
Stem sealing can be changed under pressure.
Stem is designed to be rising stem and non-rising stem, with a clear sign for valve opening.
Drive mode falls into manual, hydraulic and gear.
Combining type falls into flange, thread and hub.

3.Images of the Gate Valve
 Gate Valve Ductile Iron Rising Stem Resilient SeatedGate Valve Ductile Iron Rising Stem Resilient Seated

4.Specification of the Gate valve
Working medium: water, non-corrosive liquid, saturated vapor (≤ 0.6MPa)
Operating temperature: -20 °C ≤ t ≤ 135 °C
Stem: non-rising stem
Body material:Brass/Gray Cast Iron
Connection:flanged
(1)Forged Brass Screw Gate Valve, Brass valve, Brass Gate Valve
(2)Forged body, cast iron handle
(3)Can be changed to allum. handle
(4)Cast Iron Wheel Handle, can be changed to allum. handle
(5)Screw Ended
(6)Material: CW614N, CW617N, C37700 as per request.
(7)Thread: BSP, NPT as per request
5.FAQ
1. What's are the characteristics of gate valve?
The distinct feature of a gate valve is the sealing surfaces between the gate and seats are planar, so gate valves are often used when a straight-line flow of fluid and minimum restriction is desired. The gate faces can form a wedge shape or they can be parallel.
2. What is the structure?
Bonnets provide leakproof closure for the valve body. Gate valves may have a screw-in, union, or bolted bonnet. Screw-in bonnet is the simplest, offering a durable, pressure-tight seal. Union bonnet is suitable for applications requiring frequent inspection and cleaning. It also gives the body added strength. Bolted bonnet is used for larger valves and higher pressure applications.

Q: What does the "PN" mark on the valve mean?
The valve will usually be marked with "DN.PN." these two signs,DN refers to the valve path, and PN refers to the pressure levelFor example: DN25, PN16Refers to the valve diameter of 25mm valve, the pressure is 16 kg (1.6Mpa)
Q: Is the valve galvanized?
Butterfly valve gate, some hot-dip galvanized, and other valves are not.
Q: HH valve company in the United Kingdom, how about the valve?
Our factory boiler has this brand of valve, used for many years, has been no problem, really good.
Q: How do I open the gas valve?
Third: in the following there is a black disk like thing, commonly known as the gas sound core. This one is the same as the second one, half or all. 1, according to the routine, now the handle position shows that the valve is open. 2, if the handle rotated 90 degrees, the gas pipeline gas has no change, should be the stem slipped, can not drive the valve ball rotation. Try rotating several times. If it still doesn't work, ask a professional to check it out.
Q: What do O and S mean on the valve?
Generally used in process valves, operating conditions required to open and close, especially in the case of pneumatic actuators installed, the loss of power and gas supply valve when the state
Q: Where is it installed, what is the role, what is the material, and are there other alternatives instead of this effect?
Valve packing in the valve under the gland to prevent leakage, you can use ordinary asbestos rope and butter emergency replacement
Q: What is the flow medium of the valve?
What is the valve. If the water through the valve, the medium is water. I hope I can help you.
Q: How to carry out the valve strength test and air tightness test?
Refer to the GB/T13927 or ISO5208 standards and need to pass it to you
Q: someone else's home has valves, but also checked nothing, in addition to telephone repair, there are other ways? emergency
Get some water with your neighbors first, property. That's a lie. Other people's homes do not necessarily have water.You need to keep on pressing the property.You should live in a high-rise, if there is no power failure, that is, the water tank pump failure, and urge property repair is.I hope I can help you
Q: How to better maintain the valve?
How to maintain the valve?Enter the same as other mechanical products, but also the need for maintenance. This work well, can extend the service life of the valve, the following will introduce the valve maintenanceStorage and maintenanceThe maintenance of the purpose is to keep the valve in the custody of the damage, or lower quality. In fact, improper storage is one of the important reasons for valve damageThe valve custody, should be arranged in good order, a small valve on the shelves, large valves can be neatly arranged in the warehouse on the ground, not arbitrary lumber pile, do not let the flange face contact with the ground. This is not only for beauty, mainly to protect the valve, not to touch badBecause the storage and handling properly, hand wheel broken, crooked stem touch the fixed nut hand wheel and stem loosening loss and so on, these should avoid unnecessary losses.We temporarily on the short-term use of the valve, should remove the asbestos packing, in order to avoid electrochemical corrosion damage to the valve stem.I just entered the library on the valve, to conduct inspections, such as during transport into the water or dirt to wipe clean, re storedThe import and export of valves to use wax paper or plastic sheet sealed to prevent dirt insideThe valves on the machined surface rust in the atmosphere should be coated with anti rust oil, protectI placed outside the valve, must be covered with linoleum or tarpaulins like rain, dust items. Keep the storage of the valve clean and dry

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

Hot products


Hot Searches

Related keywords