forged Flange Gate Valve
- Loading Port:
- China Main Port
- Payment Terms:
- TT or LC
- Min Order Qty:
- 1 Piece pc
- Supply Capability:
- 200 Pieces Per Month pc/month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
forged flange gate valve
High quality and competitive price
Size from 1/4'' to 3'' inch
Specifications
Forged steel flange,gate valves,Welded gate valve, Female threaded and socket welded gate valve, Pressure sealing gate valve, Female threaded and socket welded gate valves. Extended gate valve
1. Pruducing standard:
Design: API 6D, API 608 Or ANSI B 16.34
Face to Face: ANSI B 16.10 OR API 6D
End flange: ANSI B16.5
2. Material
Body Material: Forged steel: A105, F304L, F316L, Stainless steel
Seats: PTFE, Reinforced PTFE, and hardmetal, PPL
3. Medium: Water, Oil, Steam, Nitric Acid, Acetic Acid, Carbamide Or Urea ETC, Strong oxidation medium
4. Tempreture: -30-300 or<425, <550
5. Operated Way: Lever, Gear, Pneumatic, Electric
6. Pressure: PN1.6-64.0MPa or CLASS 150-2500 LB
7. Size (Nominal Diameter): NPS: 1/4''-2''inch
- Q: Standard and specification for pressure test of valves
- (11) when the valve with drive device is tested and its tightness is tested, the sealing test shall be carried out by using the driving device to close the valve. For manual drive units, seal test shall also be done with the actuating closing valve.(12) the by-pass valve installed on the main valve after the strength test and the sealing test. The strength and tightness test of the main valve is carried out. The main valve should be opened when the closing member is opened.(13) iron valve strength test, the application of Pratia tapping valve and valve cover, check whether there is any leakage.(14) the valve test, in addition to the provisions of the plug valve to allow sealing surface oiling, other valves are not allowed in the sealing surface of the oil test.(15) when the valve pressure test, the blind plate on the valve pressure should not be too large, so as to avoid deformation of the valve, affecting the test results (cast iron valve if pressed too tight, will be damaged).(16) after the valve test pressure, should promptly remove the water and clean the valve, should also be prepared for the test record.
- Q: What is the normal temperature on the valve?
- 3. classification by operating temperature(1): ultra-low temperature valve for medium temperature of t< DEG C; 101 valve.(2): used for medium temperature valve operating temperature 101 C = t = 29 C valve.(3) at room temperature for medium temperature valve: the valve 29 <t<120 DEG C.(4) the temperature valve for medium temperature 120 = t = 425 DEG C valve(5) high temperature valve: valve used for medium temperature t>425 degrees celsius.If it helps, see it
- Q: What is the difference between the valve before the pump and the valve after the pump?
- Pump in front of the gate valve + one-way valve, after the pump connected valve, so that in the regulation can be clearly aware of the actual pump lift is large, without the impact of system pressure.Valve is the general name of pumps and valves.A valve that is not used in a pump or with a pump.Pump and valve are often associated with the use of the occasion. In other words, where there is a pump, there is usually a valve, where a valve is often required. They are all used for liquid delivery.
- Q: What do you mean by "P54" in the valve z962y-p54 100V?
- P54 is the body temperature, heavy rain or equal to 545 degrees, 100V is 10Mpa, that is 100 kilogramsThere are all the valves on the nameplate
- Q: What are the advantages and disadvantages of this method? Are there any other ways to adjust the flow rate?
- With the advantages of the pump outlet valve adjustment, 1, you can control the pump outlet pressure, 2, you can control the motor current is not more than the process conditions, 3, control motor power, to ensure the normal operation of the pump.
- Q: What does the "Z45T-16" valve mean?
- Z - gate valve4 - flange connection5 - Dark pole, stem non lifting (gate valve structure)T - copper alloy, valve sealing face code16 - pressure code, 1.6MPaMaterial code for grey cast iron valves of nominal pressure less than or equal to PN16 shall be omitted in model preparation.May refer to JB/T 308 valve model compilation method
- Q: What's the name of the valve?
- Specific models only go to the original manufacturers to find, and want to use other valve replacement is not impossible, want to provide detailed parameters. Let's go to the valve manufacturer!
- Q: What should be checked before using the valve?
- The valve must be tested before installationI. examination of documentsThe valve must check the quality documents before installation, the valve manufacturer should be nameplate, nameplate and the body should be the name of the manufacturer, valve type, nominal pressure, nominal diameter and logo, must comply with the "universal valve logo" GB 12220.Two, appearance inspection
- Q: The general signal valve installation, or other valve installation is not installed with the groove flange clamp hoop Yucca or direct way? What's the convenient way to install the following diagram? I don't understand. Neither groove, flange nor hoop. Thank you, sir!
- For clip type, the two flanges on the pipe are drawn with studs, and the middle is the butterfly valve
- Q: Where is it installed, what is the role, what is the material, and are there other alternatives instead of this effect?
- Valve packing in the valve under the gland to prevent leakage, you can use ordinary asbestos rope and butter emergency replacement
1. Manufacturer Overview
Location | Tianjin,China (Mainland) |
Year Established | 2006 |
Annual Output Value | |
Main Markets | North America South America Eastern Europe Southeast Asia Africa Oceania Mid East Eastern Asia Western Europe |
Company Certifications | CE Certificate for check valve; CE certificate;WRAS Approved;ISO9001 Certificate |
2. Manufacturer Certificates
a) Certification Name | |
Range | |
Reference | |
Validity Period |
3. Manufacturer Capability
a) Trade Capacity | |
Nearest Port | |
Export Percentage | 91% - 100% |
No.of Employees in Trade Department | |
Language Spoken: | |
b) Factory Information | |
Factory Size: | Below 1,000 square meters |
No. of Production Lines | |
Contract Manufacturing | OEM Service Offered |
Product Price Range |
Send your message to us
forged Flange Gate Valve
- Loading Port:
- China Main Port
- Payment Terms:
- TT or LC
- Min Order Qty:
- 1 Piece pc
- Supply Capability:
- 200 Pieces Per Month pc/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches
Related keywords