Specifications

The tape is mainly used in the manufacturing of fire-resistant electric wire and cable.

Mica tape (for Fire-resistant wire & cable) consist of mica paper (phlogopite paper or synthetic mica paper), the non-alkali fiberglass cloth or Polyethylene film for reinforcement (single-side or double-side), and coupled by heat-resisting organic silicone adhesive, which is cut and processed into belted product after being baked and dried. It is featured in good insulation, fire resistance,good softness, ease of wrapping wires and cables. Hence, it is applicable to main fire-resistant insulation layers of various fire-resistant wires and cables.
Mica tape for fire-resistant wires and cables is mainly classified into the category A (950-1000
°C) and B (750-800°C) base on the fire resistance grading. A may reach 1200°C,and the products in the category B are also able to normally work under the flame of 750°C for over 90 minutes.

Product Category:

Model

Name

Thickness

Application

NHJ-1

Single-side fiberglass enhanced phlogopite mica tape

0.12mm

B

NHJ-2

Double-side fiberglass enhanced phlogopite mica tape

0.14mm

B

NHJ-3

Fiberglass and film enhanced phlogopite mica tape

0.14mm

B

NHH-1

Single-side fiberglass enhanced synthetic mica tape

0.12mm

B, A

NHH-2

Double-side fiberglass enhanced synthetic mica tape

0.14mm

B, A

NHH-3

Fiberglass and film enhanced synthetic mica tape

0.14mm

B, A

Note: inner core is normally in 54mm, but can also be 76mm and 83mm; widths are available from 6mm, and when the width in 6-10mm, the outer diameter is about 240mm, can not be bigger; if the width bigger than 15mm, the maximum outer diameter can be about 340mm, but the production costs are higher too.

Technical specifications:

Phlogopite Mica Tape

Synthetic Mica Tape

Classification

B (750-800°C)

A (950-1000°C)

Mica content (%)

Single-side reinforced type ≥60

Single-side reinforced type ≥60

Double-side reinforced type ≥55

Double-side reinforced type ≥55

Organic silica-gel content (%)

≤17

≤12

Volatile content (%)

≤1.0

≤1.0

Tensile strength (N/cm)

Single-side reinforced type≥20

Single-side reinforced type ≥20

Double-side reinforced type≥100

Double-side reinforced type≥100

Dielectric strength (mv/mm)

≥10

≥10

Insulation resistance (MΩ)

≥1

≥0.4

Fire-resistant performance

No breakdown at 1KV, 800°C, 90min

No breakdown at 1KV, 1000°C, 90min


Q: Four lines only reached a phase line, at the other end all charged, I use the digital pen! In addition, I often check the cable when the cable current through the dot digital pen voltage symbols sometimes have time to disappear, in other bare wires when the test keys are normal! What is this going on! Ask the heroes to give the younger brother a complete point of the answer! More
This is too difficult to give you a way to just try: with a fine wire rope, that is, lift the clothes on the stick so thick, the end of a bend, with a tape wrapped around the head, try can not wear, wear When the possibility of rotating wire rope, if you can go through the success of the half, the key is to use the wire through the more difficult, can only use the cord, hard-line 100% make life difficult.
Q: What machinery is required to make wire and cable?
Oh, the pipeline is poured before the layout according to the design drawings.
Q: IPadmini. The latest version 7.1.1 up in the morning to see the non-stop display this cable is not certified does not support this feature. The The Charger original. Not on the computer charge. The Ask God to answer more
The problem lies in the charger between the machine, IPAD charging is to a charging protocol to complete, when the IPAD did not receive the agreement signal will be prompted: do not support this accessory, Apple's products have charging protocol, charging Is through the data line in the two lines and IPAD transmission charging protocol signal when ipad received the charging protocol signal after the machine internal charging circuit began to open the internal charging circuit to charge, the problem is to accept the charge signal is not so prompted not to Support, change the line to try
Q: Rt, the charger did not change, has been no problem before, today just plugged into the charger, the results appear as if the problem, before the out of this problem, and now only ipad power off after the power can not be charged, and ipad start , Then immediately prompted the title, can not charge more
Budget 1W5 requires the whole machine to include the display of the monitor not too big too much Not used to more
Q: Do not know why not mislead. The The The The The Fire resistance is IECGBBS6387. GB is the general principle of flame retardant and fire resistant wire and cable, quoted the above criteria...........................
Directly to find Dell customer service bar, the general warranty period are free replacement, unless the insurance of the. You can extend the warranty period, it seems you like to do the experiment.
Q: Wire and cable CCC product consistency is what
PVC line, the market is better with plastic, plastic, . Wantong, etc., if only home improvement, then the brand requirements do not need so high. Small brands are the same, we see the quality. Network cable, then preferred Ann or TCL.
Q: Decoration when the purchase of water pipes, wires and other items included in the account
Outdoor fire line must use fire-resistant KVV cable, wear pipe protection.
Q: Apple 6 Charging Why always show this cable has not yet been certified
Set-top box with the AV cable connection: yellow - video, red and white - audio, corresponding to the TV's AV input interface can be connected (do not receive the TV component interface). As for the emergence of partial pink, the possible reasons are: . poor contact. You will re-connect the three-color AV cable to the set-top box, on the TV, to ensure good contact. . cable quality. Three-color AV cable may not be the quality, if you can replace a group of try, or use the DVD and other equipment connected with the TV to test the AV line with or without problems. . TV AV input failure. You can use other video source equipment connected to the TV test, such as: DVD, VCD machines and so on. . set-top box failure. May be set-top box AV output port problems, if there are multiple sets of AV output, you can try other port okay, not the case may be the quality of set-top box, call customer service it.
Q: What are the varieties of wire and cable (detailed point)
The meaning of the letter: W refers to the halogen-free, D refers to the low smoke, Z refers to the flame retardant WDZ is halogen-free low smoke flame retardant jacket power cable. WDZC refers to halogen-free low smoke C-class flame retardant
Q: This cable or accessory has not been certified and may not be able to work with this iphone reliably
The installation process is a certain requirement, high and low voltage cable bridge should be installed separately as usual, a wall laying vertical pipeline (slot) or installation equipment, the power distribution between the depth of D1 = 1200 ~ 1500mm; weak Between the deep distance from the D2 = 1100 ~ 1400mm more reasonable. The length L1 and L2 between the power distribution and the weak can be determined according to how much electrical equipment and pipelines (slots) are installed in the room. "Civil building electrical design specifications" proposed "shaft size in addition to meet the wiring spacing and terminal box, distribution box layout must be the size, but also in the box before the left not less than 0.8m operation, maintenance distance" requirements. In the weak equipment, the operation and maintenance distance is not specified in the provisions of the Code for Electrical Design of Civil Buildings, but it should not be less than 0.8m. Cable to wear steel pipe wiring, should be reserved in the floor steel pipe, wiring should be completed after the plug fire fire blocking material. Cable bridge installation should be horizontal, the maximum sag should not be greater than 10 mm; proposed separate installation

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

Hot products


Hot Searches