Fire-resistant Mica Tape for Fire-resistant Cables

Fire-resistant Mica Tape for Fire-resistant Cables

Ref Price:
get latest price
Loading Port:
China main port
Payment Terms:
TT or LC
Min Order Qty:
10 m.t.
Supply Capability:
200 m.t./month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

Fire-resistant Mica Tape for Fire-resistant Cables

Main Structure for Fire-resistant Mica Tape

1)Width:6-50mm

2) Rated Voltage:13-18KV/MM

3)Tensile Strength:80N/cm

Mica tape (for Fire-resistant wire & cable) consist of mica paper (phlogopite paper or synthetic mica paper), the non-alkali fiberglass cloth or Polyethylene film for reinforcement (single-side or double-side), and coupled by heat-resisting organic silicone adhesive, which is cut and processed into belted product after being baked and dried. It is featured in good insulation, fire resistance,good softness, ease of wrapping wires and cables. Hence, it is applicable to main fire-resistant insulation layers of various fire-resistant wires and cables.

 

Specification for Fire-resistant Mica Tape

Model

Name

Thickness

Application

NHJ-2

Double-side fiberglass enhanced phlogopite mica tape

0.14mm

B

NHJ-3

Fiberglass and film enhanced phlogopite mica tape

0.14mm

B

NHH-2

Double-side fiberglass enhanced synthetic mica tape

0.14mm

B, A

NHH-3

Fiberglass and film enhanced synthetic mica tape

0.14mm

B, A

 

Datas information for Fire-resistant Mica Tape:


Phlogopite Mica Tape

Synthetic Mica Tape

Classification

B (750-800°C)

A (950-1000°C)

Mica content (%)

Single-side reinforced type ≥60

Single-side reinforced type ≥60

Double-side reinforced type ≥55

Double-side reinforced type ≥55

Organic silica-gel content (%)

≤17

≤12

Volatile content (%)

≤1.0

≤1.0

Tensile strength (N/cm)

Single-side reinforced type≥20

Single-side reinforced type ≥20

Double-side reinforced type≥100

Double-side reinforced type≥100

Dielectric strength (mv/mm)

≥10

≥10

Insulation resistance (MΩ)

≥1

≥0.4

Fire-resistant performance

No breakdown at 1KV, 800°C, 90min

No breakdown at 1KV, 1000°C, 90min

Pictures:


 

Q:Apple 6splus charge may not support this accessories how to do more
When the lighting circuit and the power circuit shared ladder, BV line is not allowed to put in the ladder, so it is recommended to use the wiring of the lamp ZC-YJV-3 * 2
Q:What are the T and T, s of the wire and cable test type?
May be charging head of the problem, the line may also be a problem. If the warranty can be free for the change.
Q:This cable or accessory has not been certified and may not be able to work with this iphone reliably
The installation process is a certain requirement, high and low voltage cable bridge should be installed separately as usual, a wall laying vertical pipeline (slot) or installation equipment, the power distribution between the depth of D1 = 1200 ~ 1500mm; weak Between the deep distance from the D2 = 1100 ~ 1400mm more reasonable. The length L1 and L2 between the power distribution and the weak can be determined according to how much electrical equipment and pipelines (slots) are installed in the room. "Civil building electrical design specifications" proposed "shaft size in addition to meet the wiring spacing and terminal box, distribution box layout must be the size, but also in the box before the left not less than 0.8m operation, maintenance distance" requirements. In the weak equipment, the operation and maintenance distance is not specified in the provisions of the Code for Electrical Design of Civil Buildings, but it should not be less than 0.8m. Cable to wear steel pipe wiring, should be reserved in the floor steel pipe, wiring should be completed after the plug fire fire blocking material. Cable bridge installation should be horizontal, the maximum sag should not be greater than 10 mm; proposed separate installation
Q:The data line is my online to buy the extension of the line, has been able to use, and today suddenly can not charge the electricity, and pop up the tips, which is why? More
What do you want to do? Do network cabling buried? Or in the building after the tube?
Q:Wire and cable: RVFV. : RVFSV. : UTP-CAT5E. : SYV-F-75-5 : RVFSP. : RVSP. : RVFVSP. What is the type of wire? Solve! More
If you need an unqualified wire, you can contact this part
Q:Wire and cable CCC product consistency is what
What brand of wire pipe PVC pipe used? Is not in the financial or plastic surgery better ah? Guiqiu we recommend, thank you! What brand of network cable used a good, need double shielded cable, thank you
Q:What is the difference between the WDZ wire and cable, the ZR wire cable and the NH wire and cable, and what kind of wire and cable should be used?
BV1 * 2.5 is a 2.5 square line. 2 * 2.5 is two 2.5 square lines. 3 * 2.5 is three 2.5 square lines. 4 * 2.5 is the 4 2.5 square line lighting wire power cord with 2 * 2.5. Light wire with 1.5 is enough. Socket (pipe) with three 2.5 square lines, you can also use 3 * 2.5 a. 4 * 2.5 for three-phase motors.
Q:IPhone6 This cable or accessories have not been certified how to solve
The color is easy to distinguish. General yellow on behalf of the video line, red white plug left and right audio.
Q:What machinery is required to make wire and cable?
Line pipe is poured before the concrete is laid on the cloth, fixed on the template or steel, pouring a need to install a class at any time to adjust its position!
Q:Cable a fire line power and why the other did not pick up the line with a pen test also have electricity? Answer detailed point
Megohmmeter, such as measuring insulation normal, that is, induction power, the other line after grounding, the pen measured no electricity.

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

Hot products


Hot Searches

Related keywords