• Ductile Iron Butterfly Valve Of Good Quality From China System 1
  • Ductile Iron Butterfly Valve Of Good Quality From China System 2
  • Ductile Iron Butterfly Valve Of Good Quality From China System 3
Ductile Iron Butterfly Valve Of Good Quality From China

Ductile Iron Butterfly Valve Of Good Quality From China

Ref Price:
get latest price
Loading Port:
Tianjin
Payment Terms:
TT OR LC
Min Order Qty:
50 set
Supply Capability:
1000 set/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

 

1. Manual Wafer Butterfly Valve Description

A butterfly valve is a valve which can be used for isolating or regulating flow. The closing mechanism takes the form of a disk. Operation is similar to that of a ball valve, which allows for quick shut off. Butterfly valves are generally favored because they are lower in cost to other valve designs as well as being lighter in weight, meaning less support is required. The disc is positioned in the center of the pipe, passing through the disc is a rod connected to an actuator on the outside of the valve. Rotating the actuator turns the disc either parallel or perpendicular to the flow. Unlike a ball valve, the disc is always present within the flow, therefore a pressure drop is always induced in the flow, regardless of valve position.

 

2.Main Features of the Manual Wafer Butterfly Valve 

a)Cast hole. Flange connection meet ANSI 125/150#   DIN PN10/16   BS4504 PN10/16 in the meanwhile.

 

b)Soft seat. Replaceable. Increase of service life.

 

c)Double half shaft without pin.

 

d) Square and short neck. Easy to stick scutcheon and cost saving.

 

3. Manual Wafer Butterfly Valve Images

 Ductile Iron Butterfly Valve Of Good Quality From China

Ductile Iron Butterfly Valve Of Good Quality From China

4.Manual Wafer Butterfly Valve  Specification

 Ductile Iron Butterfly Valve Of Good Quality From China

5.FAQ

 

1. What is manual wafer butterfly valve?

A: Wafer style is the more common of the two and is less expensive than the lug style. The wafer style butterfly valve is just about the standard. It ís so common that no one even bothers to use the word "wafer" when ordering a butterfly valve. It is taken for granted that if a butterfly valve is ordered, a wafer style will be received.

 

2. How about the Installation of the Wafer Style Butterfly Valve?
A: Butterfly valves are installed by inserting the valve between two flanges using bolts or studs and nuts to hold it all together. This type of installation, of course, makes it impossible to disconnect just one side of the piping system from the valve. That benefit is received using the lug style valve.

 

3. What is the working principle of manual wafer butterfly valve?

 A: A butterfly valve is from a family of valves called quarter-turn valves. In operation, the valve is fully open or closed when the disc is rotated a quarter turn. The "butterfly" is a metal disc mounted on a rod. When the valve is closed, the disc is turned so that it completely blocks off the passageway. When the valve is fully open, the disc is rotated a quarter turn so that it allows an almost unrestricted passage of the fluid. The valve may also be opened incrementally to throttle flow.

 




Q: For example, the knife gate valve, PZ73X-10C, DN50 torque is 5, torque is what role? What units?
Unit: Newton M. torque is the minimum torque used to turn on the valve. It is the force that opens the valve!The valve that indicates the opening of the PZ73X-10C DN50 requires 5 meters of force.
Q: Where is the hydrant main valve?
The intake valve of the upper and lower ring pipes of the riser of the fire hydrant is generally located at the highest and lowest floors.The general use of the valve rod flange gate valve.Hydrants, officially called fire hydrants, are a type of fixed fire fighting facilities, which control fuel, insulate fire and eliminate fire. Indoor fire hydrant and outdoor hydrant. The fire fighting system includes outdoor fire hydrant system, indoor fire hydrant system, fire extinguisher system, and some automatic sprinkler system, water gun system, gas fire extinguishing system, fire detection system, water mist system and so on. Fire hydrant mainly for fire engines from the municipal water supply network or outdoor fire water network to implement fire fighting, can also be directly connected to the hose, water gun fire extinguishing. Therefore, indoor and outdoor fire hydrant system is also one of the important fire fighting facilities.
Q: Pump, valve, these belong to the material?
In the stainless steel industry category: sheet only belongs to the material! In the mechanical and electrical equipment categories: valves in the screws, gaskets, nuts are materials! This is relative!
Q: How about leaking water pipe valve?
1, if it is household valveA, the valve and pipe connections at the leakage, in the connection, do not rub tape (the best counter clockwise direction, so that when the valve is connected, the more twisted the more tight) ;B, if the valve itself in the leak, there are ways, it is necessary to open the valve, in which to add sealed or O ring, but it is recommended to replace a more convenient.2, if it is industrial valvesA, industrial valves leaking, if not the valve itself in the leak, then in the valve and pipe connections to join the sealing ring,B, if the valve itself is leaking, it is best to return to the manufacturer for maintenance, if not convenient, then only the manufacturers to come here for maintenance.
Q: 1/2, what does 1/4 valve mean? I don't understand. What does this number mean? Have a valve to introduce me, do not copy a pile of online introduction, I want to concise
It should be said that the diameter is represented by units per inch! 15mm 6mm nominal diameter valves representing metric units!
Q: The expert can tell me how to install this valve, and what fittings to use on both sides
On the first floor, the two floor adds up to the perfect answer: look at the flow direction and weld it directly to the pipeIf the process permits, you can first weld on both sides of the flange, modified into a flange butterfly valve, and then installed on the pipe, easy to overhaul later
Q: Which valve can play a good regulatory role?
A wide range of valves, the function is different, although like conventional butterfly valve, ball valve can play a regulatory role, but their role is not linear, so if you need to adjust the precision of the valve, it is best to select the control valve.
Q: How to open the gas valve with drawings
First of all, you have to determine the direction of the valve opening, usually homeopathy, it is off, the reverse is open. First: to determine the opening of the valve, are generally ball valve, screw 90 degrees on it. Second. At the top of your house, there is a button that can be pulled out.
Q: How can the material be checked by valve approach? What experiments do you need?
May refer to the valve pressure test principle and the pressure test matters needing attention.(1) in general, the valve shall not be subject to strength test, but the body and bonnet shall be subjected to strength tests after the repair of the valve body and bonnet or corrosion damage. For the relief valve, the constant pressure and seat return pressure and other tests shall be in accordance with the specifications and the relevant regulations.(2) the installation of the valve should be done for strength and tightness test. Low pressure valve sampling 20%, if not qualified should be 100% of the inspection; medium and high pressure valve should be 100% of the inspection.(3) the installation position of the valve shall be in the direction of easy inspection during the test.(4) welding connection valve, not with blind plate pressure test can be used when the cone seal or O ring seal pressure test.(5) when hydraulic test, the valve air will be excluded as much as possible.(6) the pressure should be increased gradually during the test, and the pressure will not be sudden and sudden.(7) strength test and sealed test duration is generally 2~3min, important and special valves should last 5min. Small caliber valve test time can be a little shorter, large caliber valve test time can be longer. During the test, the test time can be extended if in doubt. Strength test, does not allow the body and bonnet sweating or leakage. Sealing test, the general rotor valve only once, the safety valve, high pressure valve and other raw valve to be carried out two times. When testing for the low pressure, large diameter valve is not important and there are provisions to allow leakage of the valve, allowing a small amount of leakage; the common valve, power station valve, marine valves and other valve requirements vary on leakage requirements according to relevant regulations.
Q: What are the most common types of valves?
Gate valve, globe valve, check valve, ball valve, butterfly valve, safety valve, drain valve, plug valve, throttle valve, plunger valve, diaphragm valve, relief valve, foot valve, drain valve etc.

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

Hot products


Hot Searches