• DN100 Cast steel Gate Valve System 1
DN100 Cast steel Gate Valve

DN100 Cast steel Gate Valve

Ref Price:
get latest price
Loading Port:
China Main Port
Payment Terms:
TT OR LC
Min Order Qty:
-
Supply Capability:
-

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

Soft seal gate valve

Size:DN40mm-600mm

Design standard: DIN 3352/BS 5163/AWWA C509/JIS B2043

Test standard: DIN3230/BS 6755/AWWA C509/JIS B2003

End flange standard: DIN 2533 PN16/BS 4504 PN16/ANSI 150LB/JIS B2212 10K

Face to face standard: DIN 3202 F4/DIN 3202 F5/BS 5163/ANSI 16.10/JIS B2002

Body: Ductile iron/GGG50/A536

Wedge: Ductile iron+EPDM/Ductile iron+NBR

Stem: Brass/SS416/2Cr13

Bonnet: Ductile iron/GGG50

Handwheel: Ductile iron/GGG50

The products are widely used in water source projects, urban water supply and drainage, sewage treatment, eletric power, petroleum, petrochemical, heat supply, shipbuilding, medicine and metallurgy industries. Equipment are used for regulating or cutting off media in pipelines. Suitable media include water sewage, sea water, air, foodstuff and oil. Suitable for gear operators, electric and pneumatic control actuators.


Q:What is the difference between the cut-off valve and the gate valve?
When opening and closing, the valve core and valve seat sealing surface always contact and rub each other, so the sealing surface is easy to wear, the valve is close to shut down, the pressure difference between the pipe is very large, so that the sealing surface wear more serious.Gate valve and stop valve advantages and disadvantages:Valve is the advantages of small flow resistance, the media can flow in two directions, but there are tall, complex structure, sealing surface easy to wear shortcomings. The flow resistance of the gate valve is 3-5 times that of the gate valve. Open and close to shut down in order to seal the valve, the valve is completely closed when in contact with the sealing surface, the sealing surface wear is very small, because the flow of the main actuator with large valve should pay attention to adjust the torque control mechanism.
Q:GB 300 gate valve, a multi?
GB DN300 flanged gate valve, PN10 manual 245kg bevel gear 315Other pressure levels, please specify specific pressure.Wenzhou Chaoda group Agel Ecommerce Ltd to provide the answer:
Q:Installation and operation instructions of knife gate valve
5., when installing the valve, users must reserve the necessary space for valve actuation;The wiring of the 6. driving device shall be carried out according to the wiring diagram;7. knife gate valve must be regularly maintained, shall not be arbitrarily collision and extrusion, so as not to affect the seal.
Q:What does gate valve Z41H-40 mean?
40 kg flanged cast steel gate valve;Flanged gate valve, 40 pressure
Q:What gate DH10016, AM
The first Z represents the gate valve (the initial consonant of the Chinese phonetic alphabet for the gate); the second 2 represents the drive mode of the valve, that is, electro hydraulic drive.
Q:What are the differences between the gate valve and the cut-off valve?
Is the gate valve opening and closing parts, RAM direction of motion perpendicular to the direction of the fluid, valve can only be fully open and fully closed, is not suitable for regulation and throttle. The gate has two sealing surfaces. The two sealing surfaces of the most commonly used wedge gate valves form a wedge. The wedge angle varies with valve parameters, usually 5o. Wedge gate valve can be made into a whole, called the rigid gate; can also be made to produce micro deformation of ram, in order to improve its process of deviation, make up the sealing surface angle in the process, the gate is called the flexible gate. Valve closed, the sealing surface can only rely on medium pressure to seal, that is to rely on medium pressure to the gate sealing surface pressure to the other side of the seat to ensure the sealing surface seal, which is self sealing. Most of the valve is forced seal, that is, when the valve closes, to rely on external force to force the gate to the seat, in order to ensure the sealing surface sealing.A stop valve is a valve that closes the valve and moves along the center line of the valve seat. According to this form of valve movement, the valve seat opening change is proportional to the valve stroke. Because of the valve stem to open or close the trip is relatively short, but very reliable cut off function, and because changes in the valve seat and the valve stroke is proportional, is very suitable for flow regulation. As a result, this type of valve is ideal for use as a shut-off or regulator and throttling
Q:Why? God, can you explain to me in detail why?
Check valve in the valve in front. To prevent water from flowing back.
Q:What are the advantages and disadvantages of flat gate valves?
The disadvantage of flat gate valve is that when the medium pressure is low, the sealing force of the metal sealing surface is insufficient, so as to achieve satisfactory sealing. On the contrary, when the medium pressure is high, if the sealing surface is not lubricated by the system media or foreign media, often opening and closing may cause the sealing surface to wear too much. Another disadvantage is that the circular motion of the circular gate in the circular flow, only when it is at the valve closed position of 50%, this valve is more sensitive to flow control. Moreover, the gate will produce severe vibration when it breaks the high-speed and dense medium flow. The valve seat can also be throttled if the seat is made of a V - shaped opening and is tightly oriented to the gate.
Q:Analysis of the advantages of elastic seat sealing gate valve?
Most of the valve is forced seal, that is, when the valve closed, to rely on external force to force the gate to the seat, in order to ensure the sealing surface sealing.When opening the gate valve, when the gate lift height is equal to 1:1 times of the gate diameter, the passage of the fluid is completely unblocked, but at run time, this position is unable to monitor. In actual use, the top of the stem is used as a sign, i.e., the open position, as its fully open position. Temperature changes appear to consider locking phenomenon, usually open to the vertex position, and then rewind 1/2-1 circle, as a fully open valve position. Therefore, the opening position of the gate valve is determined by the position of the gate (i.e. the stroke). The sealing surface is easy to wear and tear, affecting the service life. When opening and closing, gate and valve seat two sealing surface friction, sliding, to medium pressure under the action of easy to produce abrasions, wear, affect sealing performance, shorten service life.
Q:What does gate z41t-10 150 mean?
According to JB/T308-2004 "valve type programming method"Z gate valve4 flange connection1 Ming wedge single gateT sealing cover material is copper alloy10 nominal pressure PN10PN16 below no marked valve body code, body material is gray cast iron150 nominal size DN150

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

Hot products


Hot Searches

Related keywords