Dimming Driver DC12V 0-10V
- Loading Port:
- China Main Port
- Payment Terms:
- TT or LC
- Min Order Qty:
- 20 Pieces pc
- Supply Capability:
- 100000 Pieces per Quarter pc/month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
Along with the rise of LED illumination, LED lamps are widely used in hotel, business center, household decoration etc., there are more and more chances to use LED and fluorescent lights at the same project, if LED lamps and fluorescent lights can be controlled together by a traditional fluorescent dimming system, it will make everything more convenient, but the dimming principles of LED and traditional fluorescent lights are different, LED lights can not be dimmed by the fluorescent dimming controller directly.
As a fact of that, our company developed a new 0-10V to PWM dimming driver which has solved the compatible problem of fluorescent dimming system. and LED illumination, LED lamps can be controlled by many traditional intelligent dimming system.
NOTE: The CV Dimming Drive and CC Dimming Drive can be connected together on the same dimming system, which is convenient for controlling different LED lamps with different voltage and power. Signal input and output of 0-10V dimming driver have security protection function with photoelectricity isolation 5KV
Product parameter
Input voltage DC12V~DC24V
Max load current 10A/CH×1
Max output power 120W(12V)/240W(24V)
Input signal 0-10V analog dimming signal
Output signal PWM LED dimming signal
working temperature -30°C~55°C
Dimension L121×W39×H39(mm)
Package Size L123×W42×H42(mm)
Weight (G.W) 85g
- Q: Who knows how big transformers and lines the 36V transformer uses in lighting?
- Depending on your load capacity, primary voltage, site reservation, etc.. For example, 3.6KW lighting, with 4KVA transformers, the primary side 380V with 2.5 square (copper wire) enough, two times the side of 25 square.
- Q: What type of low voltage transformer should be adopted for safety lighting power supply?
- We have produced many low voltage lighting transformers, such as outdoor waterproof, high-power stage lighting, as well as indoor small power transformers, customer response, but also good! For example, Guangzhou Color Art Lighting Co., Ltd., before them, our reputation is good!
- Q: 1000 square meters low voltage.36 volts lighting power supply with multiple transformers and wires
- You must know the quantity and power of the lamp to determine the transformer
- Q: The difference between lighting transformers and control transformers
- In principle and construction, there is no difference between the two.The only difference is that the secondary coil output voltage is different.
- Q: Is the substation separate from the power and illumination transformer?
- There is only bus in the substation, and the station is connected with the transformer from the bus. If there is no electricity even in the bus, then the substation should not be considered active.
- Q: The transformer zero line has broken, has the result to the household illumination circuit?
- The power supply system in three-phase four line zero line is broken, the breakpoint of the single-phase circuit (220V) electrical burn by voltage to 380V. I met, the incandescent lamp suddenly particularly bright then the blow up of internal fuse TV has burned out. So in the three-phase four wire power supply system zero line asked to do repeat grounding in households is the reason.
- Q: Line lights, lighting transformers in use!! Can live line work?!! Be afraid of electric shock 40
- I don't know how much the output voltage of your transformer is, but the internationally accepted voltage below 36V is the voltage that is not harmful to the human body
- Q: How many A leakage protection switches are used in 5000VA lighting transformers?
- It is widely used in the electronic industry or industrial and mining enterprises, in the machine tool and the mechanical equipment, the control power of the general electric circuit, the use of the power supply of the safety lighting indicator lamp.
- Q: Can the 500 volt lighting transformer be changed into an electric welder?
- 500 VA transformer should not be used as an electric welding machine, so it is very difficult to reform the system, so it is better to buy a new electric welder
- Q: Power and lighting transformers, lighting quality will be affected much?
- The bulb adopts a luminous two stage tube combined lamp holder, and the calculation process is very complicated. The secondary voltage is different in different combinations. Because it is a direct current ignition, but also consider the efficiency of its rectifier, but the total power is unchanged.
1. Manufacturer Overview
Location | Guangdong,China (Mainland) |
Year Established | 2003 |
Annual Output Value | |
Main Markets | |
Company Certifications | 2009 China Lighting & Electrical Appliance Contest; ISO:9001-2008 |
2. Manufacturer Certificates
a) Certification Name | |
Range | |
Reference | |
Validity Period |
3. Manufacturer Capability
a) Trade Capacity | |
Nearest Port | |
Export Percentage | 61% - 70% |
No.of Employees in Trade Department | |
Language Spoken: | |
b) Factory Information | |
Factory Size: | 3,000-5,000 square meters |
No. of Production Lines | 5 |
Contract Manufacturing | OEM Service Offered Design Service Offered Buyer Label Offered |
Product Price Range |
Send your message to us
Dimming Driver DC12V 0-10V
- Loading Port:
- China Main Port
- Payment Terms:
- TT or LC
- Min Order Qty:
- 20 Pieces pc
- Supply Capability:
- 100000 Pieces per Quarter pc/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches
Related keywords