Concrete Pump Diesel Engine 181kw  Truck CE

Product Details

Basic Info.

Model NO.:HBTS80-18-181R

 

Type:Concrete Pump

Machining Process:Hydraulic

 

Certification:ISO9001: 2000

Condition:New

 

Dimension(L*W*H):7200mm*2100mm*2500mm

Weight:7010kg

 

Hydraulic Oil Pump:Bosch Rexroth/Kawasaki

Hydraulic System:Imported Parts

 

Electric Control System:Japan Mitsubishi PLC

Electric Elements:France Schneider

 

Export Markets:Global

Additional Info.

Trademark:DAKIN

 

Packing:Nude Cargo in Containers

Standard:HBTS80-18-181R

 

Origin:Xuzhou, China

HS Code:8413400000

 

Production Capacity:50 Sets Per Week

Product Description

Model*****HBTS50-13-93R***HBTS60-13-130R****HBTS80-16-145R**HBTS80-16-161R**HBTS80-16-174R****HBTS80-16-176R***HBTS80-18-181R
Dimension(L*W*H)5000*1600*18007200*2100*25007200*2100*25007200*2100*25007200*2100*25007200*2100*25007200*2100*2500
Hopper Capacity0.8m³0.8m³0.8m³0.8m³0.8m³0.8m³0.8m³
Feeding Height1280mm1380mm1380mm1380mm1380mm1380mm1380mm
Weight4500kg6200kg6500kg6800kg6780kg6780kg7010kg
Theor. delivery pressure13Mpa13Mpa16Mpa16Mpa16Mpa16Mpa18Mpa
Theor. concrete output50m³/h60m³/h80m³/h80m³/h80m³/h80m³/h80m³/h
Hydraulic SystemOpen Open Open Open Open Open Open 
Power93kw130kw145kw161kw174kw176kw181kw
Rotation speed2200r/min2200r/min2200r/min2200r/min2200r/min2200r/min2200r/min
Distribution valveS Pipe ValveS Pipe ValveS Pipe ValveS Pipe ValveS Pipe ValveS Pipe ValveS Pipe Valve
Hydraulic Cylinder Diameterφ110mmφ125mmφ140mmφ140mmφ140mmφ90mmφ150mm
Concrete Cylinder Diameterφ200mmφ200mmφ200mmφ200mmφ200mmφ200mmφ200mm
High/Low Pressure Switch AvailableAvailableAvailableAvailableAvailableAvailableAvailable
Oil Tank Volume115L230L230L230L230L230L230L
Hydraulic Oil Tank Volume460L580L580L580L580L580L580L
EngineDiesel(Deutz Weichai)Diesel(Deutz Weichai)Diesel(Deutz Weichai)Diesel(FAW Deutz)Diesel(VOLVO)Diesel(Deutz Weichai)Diesel(FAW Deutz)
Max. Theor. Vertical Reach70m100m130m150m150m150m150m
Max. Theor. Horizontal Reach210m300m390m450m450m450m450m
Hydraulic PumpHandokBosch Rexroth/KawasakiBosch Rexroth/KawasakiBosch Rexroth/KawasakiBosch Rexroth/KawasakiBosch Rexroth/KawasakiBosch Rexroth/Kawasaki
Hydraulic ElementsImported Imported Imported Imported Imported Imported Imported 
Concrete Slump 10~23cm10~23cm10~23cm10~23cm10~23cm10~23cm10~23cm
Max. Aggregate Diameter40mm40mm40mm40mm40mm40mm40mm

Concrete Pump Diesel Engine 181kw  Truck CE

Concrete Pump Diesel Engine 181kw  Truck CE


Q: What is the difference between a concrete pump and a valve?
the current domestic production is all S valve series. Now there are special high-grade concrete S-valve pump
Q: How does the cement slurry solidify inside the concrete pump?
Suggested after the completion of each operation, the pump should be about to clean!
Q: What is the difference between concrete conveyors and concrete conveyors?
The concrete pump is a special machine for conveying concrete. It is equipped with special pipes to transport concrete along the pipeline to the pouring site.
Q: Why does the concrete pump main cylinder check valve damage cause the cylinder stroke to be short and the pumping is weak?
The main cylinder discharge, long run will lead to shorter travel, when the main cylinder of the smaller volume, through the pressure (closed off the valve) can also be achieved by the preset pressure, it can not be pressed to determine whether the master cylinder seal damage;
Q: What is the depreciation period for concrete and concrete carriers and how much net residual value is
The net residual value is the portion of the value of the residual value minus the fixed asset clean-up fee payable after the expiration of the use of the fixed asset.
Q: What are the standards for the use of concrete pumps?
Pumping operation to transfer the end of the transfer pump legs, the first income after the legs, put down the ground wheel, and then receive the front legs;
Q: What is the role of the one-way valve at both ends of the main cylinder of a concrete pump truck?
Oil circuit to open the one-way valve does not work to facilitate the piston back to the cleaning room to facilitate the replacement of the piston.
Q: Concrete pump truck hydraulic system open and closed the advantages and disadvantages of what
Closed system does not need too much fuel tank, the momentary impact is smaller, variable control is convenient, less pollution, suitable for large flow system.
Q: Building concrete pump is how to bulk cement (concrete) to the high
Repeatedly, the concrete in the hopper is continuously sucked in and out of the delivery tank, through the Y-pipe and outlet connected to the pipeline to reach the point of operation to complete the pumping operation
Q: How is the mortar in concrete pumping concrete coexisting and distinguishing in a pump?
The body should maintain a slow rotation, before discharge, the simplified speed should be accelerated to 20 ~ 30s before discharge.

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

Hot products


Hot Searches

Related keywords