Raw Materials for Refractory - Brown Fused Alumina for Refractory, BFA Sands, Abrasives
- Loading Port:
- Qingdao
- Payment Terms:
- TT or LC
- Min Order Qty:
- 25 m.t.
- Supply Capability:
- 3000 m.t./month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
Brown Fused Alumina for Refractory, BFA sands, Abrasives
is fused and crystallized under high temperature from a mixture of bauxite and other and other raw materials. It is characterized by its high hardness,good toughness and shape in size. Abrasives tools made of it are suitable for grinding metals of high-tensile strength such as: carbon steel,general-purpose alloy steel,annealed malleable iron and hard broze,etc.It also can be used as refractory materials
Physical and chemical analysis for brown fused alumina:
Purpose | Specification | Chemical composition(%) | Magnetic material content(%) | ||||||||||
Al2O3 | Fe2O3 | SiO2 | TiO2 | ||||||||||
Abrasive Grade | F | 4#—80# | 95.0 Min | 0.3 Max | 1.5 Max | 3.0 Max | 0.05 Max | ||||||
90#—150# | 94.0 Min | 0.03 Max | |||||||||||
180#—240# | 93.0 Min | 0.3 Max | 1.5 Max | 3.5 Max | 0.02 Max | ||||||||
P | 8#—80# | 95.0 Min | 0.2 Max | 1.2 Max | 3.0 Max | 0.05 Max | |||||||
100#—150# | 94.0 Min | 0.03 Max | |||||||||||
180#—220# | 93.0 Min | 0.3 Max | 1.5 Max | 3.5 Max | 0.02 Max | ||||||||
F230-F1200 | 92.5 Min | 0.5 Max | 1.8 Max | 4.0 Max | — |
Application
1. it are suitable for grinding high-speed,high carbon steel
2.high-grade refractory materials
3.abrasives tool
4.grinding and polishing
5.ceramics
6.LED
7.sandblasting
8.aviation
Pictures:
If you’ve any enquiries, please don’t hesitate to let us know.
- Q:What are first rate fire resistant window materials?
- class A window not less than 1.2 hours, class B window not less than 0.9 hours, Class C window not less than 0.6 hours. technical requirments: 1, materials and accessories (1) the window frame is made with a certain strength sufficient to safeguard the integrity and stability of the steel frame or wooden frame. (2) steel frame and mound layer can choose the galvanized steel plate or stainless steel plate. Its selection standards is in line with GB12955 "Steel Fireproof Door General Technical Condition" provisions of Article 5.1. (3) wood frame and mound layer material selected from the standard should be consistent with GB14101 "General Technical Conditions of Wooden Fireproof Door" in the provisions of Article 5.1.1. (4 ) steel, wood frame the inside filler material should be incombustible material. (5) fireproofing glass can be used without affecting the fire windows fire resistance test approved product. light transmittance of glass should not less than 75% of commom sheet glass which is the same number of layers. ( 6) a sealing material between the frame and the fire-resistant glass flame retardant materials should be used, which can play the role of fireproofing and smoke insulation in case of fire (7) hardware fitting should be tested as approved supporting product
- Q:What refractories have good mechanical property resistance and heat expansion and cold contraction property?
- Explain that where you use it for and what requirements you have. Follow-up: I use it in metallurgical furnaces with the features of strong stirring and acidic residue.
- Q:What is the difference between the fire?rating and the fire resistant level of the fire-fighting equipment?
- Fire rating and fire-fighting rating are the misnomer to the building fire resistant level. The building fire risk is measured by fire resistant level. The article 3.2.1 and 5.1.7 of "Architectural design code for fire protection" have made provision respectively on the fire resistant level of plant (the storeroom) and civil construction. Article 3.0.2 of "Code for fire protection design of tall buildings" has made provisions on the fire resistant level of tall buildings. As for the warehouse building "category malonate", it refers to one of the fire risk of goods storage, which is divided into A, B, C, D, E, and each category is refined depending on the nature of different substances. "Malonate class" specified in article 3.1.3 of "building design for fire protection" refers to the flammable solid.
- Q:what's the varieties of thermal insulation material with A level fire?rating?
- the main A level fireproof material is rock wool now (note:it is rock wool not mineral wool). A1 level fireproofing, now the largest producer is Taishi rock wool Co., Ltd.; hope my answer can help you, thank you.
- Q:Can quantitative feeder be used in refractory plant? Thank you
- Yes, but the material must be no longer using a simple Q235 material
- Q:What kinds of fireproof and fire retardant materials are there?
- general classification of fire retardant materials will use A, B in the home improvement supplies. A has the best flame resistance, followed by B.
- Q:What types of steel are silicious quicksand and chromium quicksand used in respectively?
- Chromium quicksand can be used in steel-making process that has longer refining time like LF, VD and RH, in stainless steel drainage and thin plate drainage agent. Silicious quicksand is used in short steel-making process, process that is less than 45 seconds or process without refining. You can consult Hua Heng for details or inspect it by yourself.
- Q:What's the B grade fireproofing material?
- B1 grade ceiling material: gypsum board, fobrous plasterboard, cement particle board, mineral wool decorative acoustic panels, glass wool decorative acoustic board, perlite decorative acoustic board, flame retardant plywood, flame retardant medium density fiberboard, rock wool decorative sheet, flame retardant wood, aluminum foil composites, flame retardant phenolic laminate, aluminum foil glass fiber reinforced plastic composite material, etc.; B1 grade wall material: gypsum board, fibrous plasterboard, cement particle board, mineral wool board, glass wool board, perlite board, flame retardant plywood and medium density fiberboard, fireproof plastic decorative sheet, nonflammable double-sided particle board, multicolor coating, flame retardant wallpaper and wall cloth, flame retardant simulated granite decorative plates, magnesium oxychloride cement prefabricated wall panels, flame retardant glass fiber reinforced plastic plates, PVC plastic clapboards, high-strength and lightweight composite wallboards, fire-retardant molded wooden composite boards, flame retardant colored artificial boards, nonflammable glass fiber reinforced plastics, etc.
- Q:Who knows the fire endurance of B-level fireproof doors and windows?
- According to the fire endurance, fireproof doors can be divided into A-grade, B-grade and C-grade, whose fire endurance should not be less 1.2h, 0.9h and 0.6h respectively. Fire endurance of fireproof windows: A-grade fireproof windows are not less than 1.5h and B-grade fireproof windows are not less than 1h. The door leaves of A-grade and B-grade fireproof windows should be steel materials, and their glass should be composite fireproof glass whose thickness is no less than 26mm. Monolithic fireproof glass window is not B-grade fireproof window, nor A-grade fireproof glass window. It si called non-insulated fireproof window.
- Q:How to measure the influence of high-temperature performance of the products refractory in the formation of the liquid phase.
- Generally how can do high-temperature performance to measure how much liquid may affect hot bending strength rul refractoriness levels of high temperature creep?
1. Manufacturer Overview |
|
---|---|
Location | |
Year Established | |
Annual Output Value | |
Main Markets | |
Company Certifications |
2. Manufacturer Certificates |
|
---|---|
a) Certification Name | |
Range | |
Reference | |
Validity Period |
3. Manufacturer Capability |
|
---|---|
a)Trade Capacity | |
Nearest Port | |
Export Percentage | |
No.of Employees in Trade Department | |
Language Spoken: | |
b)Factory Information | |
Factory Size: | |
No. of Production Lines | |
Contract Manufacturing | |
Product Price Range |
Send your message to us
Raw Materials for Refractory - Brown Fused Alumina for Refractory, BFA Sands, Abrasives
- Loading Port:
- Qingdao
- Payment Terms:
- TT or LC
- Min Order Qty:
- 25 m.t.
- Supply Capability:
- 3000 m.t./month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches
Related keywords