Specifications
non-insulated aluminum flexible duct
extension rate:1:10
Low /medium pressure central HVAC system flame and heat resistant
Aluminum ventilation hose aluminum foil air duct expandable aluminium ducting
Material:
Double layers of aluminum foil reinforced with high tensile spring steel wire
Structure: High elastic wire, aluminum foil. A reinforcement model can be required.
Aluminum foil thickness: 0.035mm
Temperature range: -30°C~+140°C
Maxim Air Flow: 30m/s
Maxim working pressure: 2500 pa
Standard Length: 10m/pc Or as your requirement
Fire resistance: Non flammable.
Normal packing: In carton. Or as your requirment
Application: Low /medium pressure central HVAC system and ventilation system.
Application: Used in gigh pressure,low pressure air conditioner and ventilation system,easy installation, anti-temperature and inflaming retarding etc
Description | 100% Non-asbestos |
Raw Materials | Cement,Quartz Sand,Paper Pulp,etc. |
Standard Size | 1220mm×2440mm or 1200mm×2400mm |
Max Width | 1220mm |
Max Length | 3000mm |
Thickness | 4-20mm |
Density | 1.30-1.50g/cm3 |
Color | Light yellow or Grey |
FAQ
Width: 600, 1000,1200mm
Length: 600,1200,2300mm
Thickness: 25-100mm
Density: 24-96kg/m3
Thermal conductivity: 0.034-0.048W/mK
- Q:Drain flexible pipe to keep the base design above the elevation of the number of meters
- Fourth, the internal structure of the flexible pipe joints and KRJ internal structure is slightly different, flexible pipe joints without back Taiwan or small back out of the station, while the latter is the big back five, flexible pipe fittings standard clamp type flexible pipe fittings disassembly Of the time can be used grinding demolition, shoulder type flexible pipe joints can not Note: Some units on the market now mix these two products, the purpose is to sell low prices for low-priced products, so you can get more profit margins To ask for the data parameters of the drawings to determine whether the flexible pipe joints or flexible pipe joints
- Q:What is the difference between a flexible pipe and a rigid pipe? What types of pipes are used for drainage pipes, heat pipes and gas pipelines?
- However, these three tubes have good seismic performance, strong sealing, construction is simple, easy maintenance, the use of reliable and so on, it is also known as the cast iron pipe Which W-type cast iron pipe is subdivided into W-type cast iron pipe and W1-type cast iron pipe, the main difference between the two is the difference between the wall thickness, because the difference between the north and south temperatures, the northern cold weather on the pipe requirements higher , So in general W-type cast iron pipe is mainly used for the north, and W1-type cast iron pipe is mainly used for the South side
- Q:What is the difference between the D-LD2000 clamp-type flexible fittings and the KRJ-type clamp-type flexible fittings?
- Polystyrene board in the basement wall from the role of waterproof protective layer is to prevent the backfill due to external forces on the destruction of the waterproof layer. That the use of multi-layer board bear two Cao Dutch 丨 sell Zhatai Chun Jun can not. Because the deformation capacity of polystyrene board is relatively large. And the deformation capacity of the multilayer board is small.
- Q:The sound of water pipes will not produce infrasound damage to the human body?
- Most of the polyethylene benzene board insulation, paste the external walls.
- Q:What materials are made of flexible pipes? Why should the mechanical ventilation set the flexible tube? Where should I be located?
- Masonry structure construction, the number of pole set which several
- Q:CAD type too much (including civil engineering, interior spring design, motor, machinery manufacturing and many other), a beginner how to choose?
- Extrusion plate (XPS) is a polystyrene resin or its copolymer as the main component, add a small amount of additives, made by heating and extrusion with a closed-cell structure of the rigid foam
- Q:On the classification of car repair, the best details Thank you Such as sheet metal workers, car circuits, etc. Thank you
- first of all, this is a very professional problem, there are many kinds of maintenance shelves, materials are divided into wood, bamboo, steel pipe, etc
- Q:Plastic tube most afraid of what the East unitary
- The bonding strength of the gypsum board and the extruded polystyrene plate is ≥010MPa, and the interface is in the extruded polystyrene board The bond strength of the bonded gypsum and the composite plate is ≥010MPa The combustibility of the composite plate reaches B1 level Construction technology points: the installation of the board between the natural close (including the long board) does not leave; for long board, should be installed before the hardening of the bonding material can be carried out; per square meter composite board with at least 2 Expansion of the anchor, each commonly used specifications of the composite board at least 6 expansion anchors evenly anchored to the grass-roots wall; external walls and internal wall connection should be extended to the wall, the width should not be less than 300mm; And wall bonding area ≥ 30% Applicable conditions and scope: hot summer and hot summer and warm winter area outside the building insulation works
- Q:To ask why the use of clamps connected to the spray pipe after the flush again after the water there will be a lot of hook link position leakage phenomenon? Thank you! The The
- It should be JGJ130-2001 Ministry of Construction 2001-02-9 approved 2001-06-01 implementation
- Q:How to optimize the construction management to improve the quality of construction projects
- I suggest you look at Google, there will be a lot, I hope you can find a satisfactory, I wish you a happy life!
1. Manufacturer Overview |
|
---|---|
Location | |
Year Established | |
Annual Output Value | |
Main Markets | |
Company Certifications |
2. Manufacturer Certificates |
|
---|---|
a) Certification Name | |
Range | |
Reference | |
Validity Period |
3. Manufacturer Capability |
|
---|---|
a)Trade Capacity | |
Nearest Port | |
Export Percentage | |
No.of Employees in Trade Department | |
Language Spoken: | |
b)Factory Information | |
Factory Size: | |
No. of Production Lines | |
Contract Manufacturing | |
Product Price Range |
Send your message to us
Square Flexible Duct for Aluminum Ventilation Use
- Loading Port:
- Shanghai
- Payment Terms:
- TT or LC
- Min Order Qty:
- 1000 pc
- Supply Capability:
- 20000 pc/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches
Related keywords