Flexible Duct for HVAC - Aluminum Combined Flexible Duct
- Loading Port:
- China Main Port
- Payment Terms:
- TT OR LC
- Min Order Qty:
- -
- Supply Capability:
- -
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
Specifications
8 inch insulated flexible aluminum air duct heating and cooling systems
1.high quality insulation material
8 inch insulated flexible aluminum air duct heating and cooling systems
Product Material
10m length aluminum insulation ventilation duct with low priceis made of aluminum foil +fiberglass+aluminum foi+steel wire
Product Feature
8 inch insulated flexible aluminum air duct heating and cooling systems following feature:
1.Size. (Customer's color requirement can be matched)
2.Color. (Customer's color can be fulfilled )
3.Non-toxic .Harmless to people even long time exposure
4.Excellent light transmission. transparent rate above 92%
5.Excellent weather resistance. performance can’t be change easily by Sunlight and Rain
6.Excellent Design.Personalized design and Human design with mordent concept
Product Advantages
8 inch insulated flexible aluminum air duct heating and cooling systems following advantages:
1.Material .environmentally friendly Acrylic
2.High Ruggedness.hard to attrit ,break and damage
3.Good anti-aging Properties .Long Using life Above 5 years
4.Strong Impact resistance .16 times than that of ordinary glass
5.Logo imprinting .Customer's Logo can be imprinted personally
6.OEM.ODM service. Satisfied related service can be offered in short time
7.Competitive price.Price at various level can cater your various requirement
8.Reasonable Delivery time.Fast to arrive at your office By air or Sea
9.Sample .Sample available for your proof and final decision
10.Trial Order are hotly welcome and allowed
Product Details
8 inch insulated flexible aluminum air duct heating and cooling systems
Material of Core Duct | Aluminum/fiberglass/polyester, Steel wire |
Thickness of Core Duct |
25~ 27 mm
|
Fire Resistance | Yes,Good |
Thickness of Insulation | 25mm/50mm (Polyester) |
Density of Insulation | 16kg/m3/32kg/m3 (Polyester) |
Air Velocity | 30 m/s |
Operating Pressure | 3000 Pa |
Operating Temperature Range | -30 °C/+150 °C |
Available Diameters | 50mm - 7500mm |
Available Lengths | 1m - 10m |
Packing | Paper carton box with Polyethylene bag inside |
Diameter of Duct (mm) | Steel wire thickness (mm) | Steel wire spacing (mm) |
102mm | 0.9mm | 30mm |
127mm | 0.9mm | 30mm |
152mm | 1.0mm | 35mm |
203mm | 1.1mm | 40mm |
254mm | 1.2mm | 45mm |
305mm | 1.2mm | 45mm |
315mm | 1.2mm | 45mm |
400mm | 1.2mm | 45mm |
Our Service
1.Competitive price
2.Fast produce time
3.Low MOQ
4.Excellent ODM service
5.Dominant OEM service too
6.Samples available for reference
7.Diverse Logo imprinting service .Engraving , Silk screen imprinting .Full color imprinting
- Q: How to optimize the construction management to improve the quality of construction projects
- I suggest you look at Google, there will be a lot, I hope you can find a satisfactory, I wish you a happy life!
- Q: Can the kitchen sewage pipe pass through the walls of the stove wall?
- scaffolding pole base with the height must be high longitudinal bar to the lower extension of the two spans and pole fixed height difference should be 1m by slope slope of the vertical axis of the slope should be 500mm single, double Row scaffolding bottom step should be 2m single row, double row and full of scaffolding stand in addition to the top of the top step outside the other layers of each step must be connected with the fastener scaffolding pole connection, lap should be consistent with the column Provisions: the use of connecting rods should be staggered with two adjacent rods should be arranged to set the synchronization within the synchronization within the separation of the two-phase separation of the distance from the distance to 500 mm; each connected to the main node the use of lap joint lap joint should be at 1m and should be used less than 2 rotating fasteners fixed end fastener cover edge to the rod end distance should be 100mm scaffolding Pole top rail bar should be high wall end 1m should eaves mouth 15m
- Q: Safety evaluation: gas pipeline and discharge pipe should not be set between the valve, what is the specification of which provisions?
- In the past, the external wall insulation technology prevails, the external wall insulation is in the experimental stage, Basically no
- Q: On the classification of car repair, the best details Thank you Such as sheet metal workers, car circuits, etc. Thank you
- There are also special materials such as bamboo, so rare, no longer introduced
- Q: What is the difference between a rigid pipe and a flexible pipe, what kind of pipe is rigid, what is flexible
- According to the requirements of the "Construction Engineering Safety Protection and Civilian Construction Measures Fees and the Use and Management Regulations", the document shall include at least the following parts: 1. Safety equipment: safety nets, safety belts, helmets, etc .; , The entrance and the edge of the protection facilities: stairs, elevator, channel mouth, reserved hole, balcony around the floor around the roof around the foundation pit, unloading platform on both sides of the platform and the upper and lower access and other security facilities; . tower cranes, external elevators, well frame hoists and other construction works from the construction of the steel, the use of high-quality steel, Heavy equipment and supporting protective facilities; Fifth, the construction of electricity: in line with regulatory requirements of the temporary electricity system, the standardization of electrical boxes, electrical protection devices, power lines laying, foreign protection measures, etc .; six, construction machinery; : Including the construction of lifting equipment and external elevators, safety nets, steel scaffolding and other detection. Ten, safety education and training; nine, safety signs, signs and safety publicity column; ten, civilized construction and environmental protection: construction site fencing and site hard ground, dust control, noise control, drainage measures, , Temporary facilities: including offices, dormitories, cafes, toilets, shower, etc .; . fire equipment and facilities; thirteen, emergency rescue equipment; . foundation pit deformation monitoring; fifteen, underground safety Protection and monitoring.
- Q: Is the clamp type flexible connector connected to the pipe to the rubber pad?
- Construction safety inspection standards (JGJ59-2011) a total of 19 inspection items, they are 1. Safety Management 2. Civilized construction. Fastener steel scaffold 4. Door steel scaffold 5. Bowl button steel pipe scaffolding 6. Socket type plate fastener type steel scaffolding 7. Full house scaffolding 8. Suspended scaffolding 9. Attachment lift scaffolding 10. High operating basket 11. Foundation Pit Engineering. Template holder 13. High work 14. Construction electricity 15. Ingredients Red Chrysanthemum Chrysanthemum Chrysanthemum. Construction lift 17. Tower crane 18. Lifting hoisting. Construction tools hope to help you.
- Q: Heating pipe through the deformation of the joints, the album is written on the "metal hose", the problem one: This is a flexible hose? Question 2: how to set the quota
- First, according to its structure can be divided into: scaffolding according to its structure can be divided into: multi-pole, bowl button, door type, square tower, attached lift frame and hanging scaffolding. Second, the knowledge expansion: scaffolding by setting the form can be divided into: single row scaffolding only a row of pole scaffolding, the other side of the horizontal bar on the wall structure. double scaffold scaffolding with two rows of poles. multi-row scaffolding with more than 3 rows of pole scaffolding. full of scaffolding according to the scope of construction work full, both directions have more than 3 rows of pole scaffolding. Full scaffolding The maximum height of the wall or construction work, the scaffolding set by the height of the ground. Scroll (Peripheral) Scaffolding Scaffolding that is set up and intertwined along a building or range of work. Scaffolding Scaffolding with special flat and space shapes, such as for chimneys, water towers, cooling towers and other flat, circular, "outer", polygonal and upper, Form of construction scaffolding.
- Q: CAD type too much (including civil engineering, interior spring design, motor, machinery manufacturing and many other), a beginner how to choose?
- The concrete structure has been included in the structure, but the concrete structure is a concrete structure, but the structure is just a frame structure without concrete structure; another steel structure and concrete structure is a good idea but to do Less, the third floor is said to be the main structure of the original structure, masonry works using concrete, then this will undoubtedly increase the cost of the house, if not very high floor or earthquake area is clearly not economical
- Q: Plastic tube most afraid of what the East unitary
- In general, polyurethane sandwich panels can be used in a variety of building needs, including industrial plants, public buildings, combined housing, purification projects and other construction areas
- Q: To ask why the use of clamps connected to the spray pipe after the flush again after the water there will be a lot of hook link position leakage phenomenon? Thank you! The The
- It should be JGJ130-2001 Ministry of Construction 2001-02-9 approved 2001-06-01 implementation
Send your message to us
Flexible Duct for HVAC - Aluminum Combined Flexible Duct
- Loading Port:
- China Main Port
- Payment Terms:
- TT OR LC
- Min Order Qty:
- -
- Supply Capability:
- -
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches
Related keywords