WSM-315 400 IGBT Series Inverter DC Pulse Argon Arc Welding Machine
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
WSM-315/400 IGBT Series Inverter DC Pulse Argon Arc Welding Machine
Quick Details
· Condition: New
· Place of Origin: China (Mainland)
· Brand Name: OEM
· Model Number: WSM-315I WSM-400I
· Pilot Arc Current: 10-315 10-400
· Rated Duty Cycle: 60%
· Dimensions: 566*290*500
· Usage: Welding
· Voltage: 380V
· Certification: ISO9001
· certificate: ISO9001:2008
· Authentication: CCC
Characteristic
1. Starting arc by high frequency oscillation when argon arc welding, reliability, steady function.
2. Independent control pulse frequency and duty cycle.
3. Faster response after short circuit in welding rod and workpiece during melt drip procedure.
4. Automatic control starting arc and end arc makes arc steady.
5. One machine with several purposes.
Technical Parameter
Model | WSM-315IGBT | WSM-400IGBT |
Rated Input Voltage(V) | 3~380 | 3~380 |
No-Load Voltage(V) | 54 | 54 |
Rated Input Power(kV/A) | 12.8 | 18.6 |
Output Current Range(A) | 5-315 | 5-400 |
Rated Welding Voltage (V) | 32.6/22.6 | 36/26 |
Rated Duty Cycle (%) | 60 | 60 |
No-Load Loss(W) | 100 | 100 |
Efficiency (%) | 85 | 85 |
Pulse Frequency(Low) Hz | 0.25-2.5 | 0.25-25 |
Pulse Frequency(Middle) Hz | 25-250 | 25-250 |
Current Up-Slope Time(S) | 0-10 | 0-10 |
Current Down-Slope Time(S) | 0-10 | 0-10 |
Background Current(A) | 5-315 | 5-400 |
Starting Arc Current(A) | 5-315 | 5-400 |
Ending Arc Current(A) Time (S) | 5-315 | 5-400 |
Post Flow | 0-10 | 0-10 |
Duty Cycle% | 0-10 | 0-10 |
External Size L*W*H(mm) | 566*290*500 | 566*290*500 |
Weight (kg) | 33 | 37 |
- Q: What kind of antifreeze is used in water-cooled argon arc welding machine in winter?
- Anti freezing cooling fluid for automobile, it can be used in water cooled arc welding gun in winter.
- Q: I see the model number "IA-300ITPS". What does that mean?
- Ordinary argon arc welding machine can not be welded Aluminum Alloy, because Aluminum Alloy welding is the need to have a function of the cathode is broken, but the common DC argon arc welding machine is the function, does not have the function of communication so I do not have the function of broken cathode.The theory of ordinary argon arc welding of DCRP welding can be Aluminum Alloy, but the effect is very poor, easy to collapse and forming oxide matrix, are more difficult to forming good.
- Q: Reallink 200 argon arc welding machine, can long time continuous welding
- Certainly not. It's a civil level
- Q: It can not be adjusted by ordinary welding
- Or adjustment switch is a problem, and then either 380 of the welding machine connected to 220 of the power supply, and the last case, high voltage package problems.
- Q: The difference between AC argon arc welding machine and DC welder
- The difference lies in the use of different welding and argon arc welding machine with gas tank, and DC welder need only electrical and conventional electrodes. Argon arc welding of metal material processing is very thin, and DC welding processing thickness less than 3MM material processing inconvenience. TIG welding wire electrode is disc type electrode. The different DC welder.
- Q: Why argon arc welding only fires without current?
- From what you say, in fact, is in the high frequency oscillation of argon arc welding machine transmitter, reach hundreds of thousands of volts in instantaneous voltage, forced air breakdown (when used to Caution!) so as to achieve the positive to negative contact! But now pulses are better than high frequency ones!
- Q: How to weld aluminum material with argon arc welding machine
- Argon arc welding machine for welding aluminium material needs AC welding machine.The oxide film of aluminum must be broken.
- Q: Argon arc welding machine does not arc, ground wire, welding torch is normal, what's the matter?
- Shut down, use multimeter diode to block test output, correct reverse value, if 0, the two side output rectifier short circuit, disassemble the rectifier group connection board to measure each diode, find out the damaged replacement. If the positive and negative values are large, the output inductor is broken open, which needs to be maintained as usual, and the damage or ablation of the common coil joint is more common, or replaced or re wound.The above two situations are the welding machine has the high frequency not to have the arc common reason.
- Q: Just bought a reallink argon arc welding WS200S, there is a gas delay switch, I do not know how to use, who can answer! Thank you
- 2.5S and 5S conversion, how long will it take to use?
- Q: What are the welding electrodes and argon arc welding machines used for welding machines?
- Stainless steel wire! I just do stainless steel, what do not understand, despite asking me!
Send your message to us