• valve of china 5000 System 1
  • valve of china 5000 System 2
  • valve of china 5000 System 3
valve of china 5000

valve of china 5000

Ref Price:
get latest price
Loading Port:
China Main Port
Payment Terms:
TT OR LC
Min Order Qty:
-
Supply Capability:
-

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing




Quick DetailsStandard or Nonstandard:  Standard Structure:  Gate Pressure:  Medium Pressure
Power:  Manual Material:  Casting Temperature of Media:  Medium Temperature
Media:  Water Port Size:  DN40mm-DN300 Place of Origin:  China (Mainland)
Model Number:  GF4 resilient gate valves:  resilient seat flange

Packaging & DeliveryPackaging Detail: air plastic bag inside/wooden box outside
Delivery Detail: 15-60days

SpecificationsDIN3352 F4 resilient seat flange gate valves
1.size:DN40-DN300
2.medium:water
3.standard:DIN
4.certificate:ISO9001 CE

resilient gate valves
1.size:DN40-DN300
2.medium:water
3.certificate:ISO9001 CE
4.standard:DIN

available medium:water
working temperature:≤80oC

flange dimensions:DIN2501

face to face dimensions:DIN3202F4.


Q:How do you draw the butterfly valve in the engineering drawing?
There is one of the most stupid way: find a picture of the butterfly valve, insert into the CAD, and then follow the trace, and there is a lot of CAD on the network of butterfly valve, yourself down..
Q:Butterfly valve D41W-1, 41, W, 1, respectively, what does that mean?
This butterfly valve in our factory called butterfly, 4 represents the connection of the flange connection flange is French, 41 in 1 on behalf of butterfly valve, W represents the body seal, is C that is actually the correct type of cast steel, should be D41W-1C. Suitable for ventilation, smoke, and these media.
Q:For example, the arrow above is from left to right, and the direction of my current is from right to left. Is that ok? I have a diameter of 700 of the hard seal butterfly valve is so installed, but it will leak water, it will not leak, very serious
The direction of the arrow on the valve body is cast, refers to the flow of media, users see the arrow, the arrow direction according to the logical and installation, this installation has become a habit, it is easy to accept the installation instructions, according to the national standard is not what error. But in the eccentric butterfly valve is installed so that sometimes there will be some problems, said the following example: according to the flow of eccentric butterfly valve with the medium flow consistent installation, tube medium is liquid, after the valve is closed, if the original direction of medium inlet pressure, reduced or zero, the export of medium reflux reflux, if senior supply, resulting in the high pressure medium, the pressure is greater than the inlet pressure, the valve will be subjected to reverse pressure, because the hard seal butterfly valve as a one-way valve so that the use is not conducive to sealing butterfly valve, and there will be leakage.
Q:Can the inlet and outlet of butterfly valve be reversed? Why? What will happen if the reverse gear is installed?
Hard seal butterfly valve in any case, the reverse loading will cause tight seal.
Q:The water supply pipe is the gate valve And on the cross dry pipe are the gate valve? To answer the 30
1, this is a good question, it seems that this has not yet made a unified standard requirements, a bit confused2, personal understanding of fire water supply pipe, pipe shall be installed on the valve, because the valve is fully open all closed features of fire control system is usually required is fully open, easy management features are obvious.3, fire water supply system is also useful to butterfly valve, but mainly signal butterfly valve.The signal butterfly valve is generally installed in two parts: floor level, dry pipe, flow indicator front end, trunk pipe, wet alarm valve, front end.Floor level pipe installation is a function of the signal valve, when the floor spraying system needs repair, close the valve, open the end of the floor drain, emptying the water in the spray system, maintenance; two is the sprinkler system is not allowed inside water, when the butterfly is closed, will transmit a signal to the the fire alarm system, fire alarm system receives a monitoring signal (so called signal butterfly valve), fire sprinkler system that the floor is anhydrous state, fast repair.Wet alarm valve at the front of the signal butterfly valve with the main floor of the main role of the butterfly valve, first, maintenance, and two is the prompt sprinkler system, there is a signal butterfly valve closed, should be repaired as soon as possible.
Q:I want to switch off the water in the bathroom only due to replacing sink taps, will water still come out of the pipe if i turn the stop valve
Only water what is still in the pipes will come out but you will lose all your hot water in the hot water cistern if you have that type of hot water storage tank.
Q:What does the butterfly valve D361H - 25C DN350 mean?
Welded turbine butterfly valve, hard seal, material: cast steel, pressure 25KG, caliber 350MM
Q:Butterfly valve D71X-10 and butterfly D371X-10 what is the difference?
Different structure. The handwheel (or handle) of the D71X-10 is mounted directly on the valve stem, and the D371X-10 is operated by means of a bevel gear in combination with the worm, and the handwheel is mounted on the worm.
Q:1st where is my zone valve? I have an old Burnham gas baseboard heater2nd What do I do?My last resort is calling a proffesional.
if your sure its not the thermostat than the zone valve should be near the boiler in the copper line. Most valves have a flat lever that slides when it is powered up to open. You can open manually by sliding the lever
Q:The difference between butterfly valve and gate valve
Its varieties and quantities are still expanding, and the development of high temperature, high pressure, large caliber, high sealing, long life, excellent regulation, as well as multi-function development of one valve. Its reliability and other performance indicators have reached a high level. Disadvantages, there is a certain resistance to the medium. Gate valves are more used in steam pipes and large diameter water supply pipelines, because of the general requirements of fluid resistance is small, the use of gate valve. Valve is hand wheel rotation, stem upward movement. Flow is not the same, the gate valve requires full open. Need a higher installation space, the valve sealing surface has a certain self sealing capacity, its spool by the media pressure closely with the valve seat sealing surface contact, to achieve tight leakage.

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

Hot products


Hot Searches