• Three Phase K3RT OEM AC Coil Magnetic Electric Contactor System 1
  • Three Phase K3RT OEM AC Coil Magnetic Electric Contactor System 2
  • Three Phase K3RT OEM AC Coil Magnetic Electric Contactor System 3
Three Phase K3RT OEM AC Coil Magnetic Electric Contactor

Three Phase K3RT OEM AC Coil Magnetic Electric Contactor

Ref Price:
get latest price
Loading Port:
Shanghai
Payment Terms:
TT OR LC
Min Order Qty:
500 pc
Supply Capability:
10000 pc/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

Three Phase K3RT AC Coil Magnetic Electric Contactor   

1.Application

K3RT AC Coil Magnetic Electric Contactor is suitable for using in the circuits up to the rated voltage 660V AC 50Hz or 60Hz, rated current up to 95A, for making, breaking,frequently starting & machine-interlocking device etc,it becomes the delay contactor,mechanical interlocking contactor ,star-deltastarter. With the thermal relay,it is combined into the electromagnetic starter.

2.Specifications

Three Phase K3RT OEM AC Coil Magnetic Electric Contactor

3.Pictures

3.Our Servicce

Cooperate with us, we will be honored and you will benefit from:

1.- Your client satisfied on the right schedule and quality;

2.- Your can get good reputation from your market and obtain more orders;

3.- Our professional service before and after sale;

4.- The reasonable price;        9A CE AC contactor

5.- Any questions from you are welcome and will be replied in 24 hours.


 4.Package & Shipping

 

  • Package : polybag and carton box  export standard package or designed by yourself 

  • Delivery date :within 3 weeks after get payment              9A CE AC contactor

  • Delivery  mode: Ocean shipping, Air transport, Express delivery/( Choose by the customer)

  • Payment terms: T/T in advance, L/C at sight. 


 

Q 1.How about your experience?

A.We have our own professional factory and R&D department & more than 10 years producing experience

Q 2. What's your advantage ? 

A. We have complete set of machines such as ,injection molding machines and punchers,

with these,we can make by ourselves from the inside parts to outside.

It greatly increases the efficiency and saves the cost.

Q 3. How's the delivery time ? 

A. usually it will take about 15-30 days for production

Q 4. Tell me the standard of package? 

A. For inner box and master carton are made as per international standards,

and we can make special design for you if need.

Also if necessary, will be packed in pallet to avoid any damage.

Q 5.Will be any warranty for your item ? 

A. We offer one year warranty for our products. Please feel assured.

Q 6.Do you accept OEM business ? 

We accept OEM authorization.



Q: What parts of the contactor
electromagnetic actuator, bracket, auxiliary contacts and shell (or chassis) composition.
Q: What are the principles of selection of contactors?
When the rated current of the contactor main contact is selected, the rated current of the main contact shall be equal to the rated current of the load
Q: What about the number of AC contactors?
and the auxiliary normally open contact is disconnected , Thereby cutting off the power supply
Q: Three-phase AC contactors have several useful clients?
Also note that the voltage applied to the power supply is much (220V or 380V), are generally marked.
Q: Application of Virtual Instrument Technology in Parameter Detection of Switchgear
The detection of the relay time parameters is mainly made by the method of simulation test such as electric stopwatch and light oscilloscope
Q: What does the contactor lock mean?
Self-protection is through the stop button to take a power cord connected to the contactor on the open end of the point, open the other end to the contactor coil, s
Q: How does the contactor interlock?
Interlocking is the two contactors can not be connected at the same time, generally used in the motor reversing circuit
Q: Why should the thermal relay be used with the AC contactor
When the push button SB2 is pressed, the AC contactor coil KM is energized and its main contact is closed, so that the motor is started and the auxiliary contact is closed from the self-locking action.
Q: What causes the AC contactor to be damaged
. Increase the power capacity, replace the line repair control contact 3. Replace the coil
Q: The Development of Electrical Performance Testing Technology for Contactors
The data processing in the literature mainly focuses on the calculation of power grid frequency and power factor

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

Hot products


Hot Searches

Related keywords