GMC-09,12,18,22 AC Contactor / GMC Series
- Loading Port:
- China Main Port
- Payment Terms:
- TT or LC
- Min Order Qty:
- 10 Pieces pc
- Supply Capability:
- 10,000 Pieces per Quarter pc/month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
1.GMC-09,12,18,22 AC Contactor / GMC Series
2.Various Quality Levels for Selection
3.Certificate: CE/ISO9001/ROHS
4.OEM is OK
Aplication:
GMC electrical contactor is suitable for using in the circuit up to the rated voltage 660V AC 50HZ or 60HZ, rated current 9~85A .
GMC AC contactor is suitable for using in the circuit up to the rated voltage 660V AC50HZ or 60HZ, rated current up to 85A, for making, breaking, frequently starting & controlling the AC motor. Combined with the auxiliary contact block, timer delay & machine-interlocking device etc, it becomes the delay contactor, mechanical interlocking contactor, and star-delta starter. With the thermal relay, it is combined into the electromagnetic starter.
Mode | GMC-9 | GMC-12 | GMC-18 | GMC-22 | GMC-32 | GMC-40 | ||
IEC-60947 AC1 duty | 20A | 20A | 25A | 32A | 50A | 60A | ||
UL AC3 duty | 200-240V | 2.5KW 11A | 3.5KW 13A | 4.5KW 18A | 5.5KW 22A | 7.5KW 32A | 11KW 40A | |
380-440V | 4KW 9A | 5.5KW 12A | 7.5KW 18A | 11KW 22A | 15KW 32A | 18.5KW 40A | ||
500-550V | 4KW 7A | 7.5KW 12A | 7.5KW 13A | 15KW 22A | 18.5KW 28A | 22KW 32A | ||
690V | 4KW 5A | 7.5KW 9A | 7.5KW 9A | 15KW 18A | 18.5KW 21A | 22KW 25A | ||
Continuous current(th) | 20A | 25A | 30A | 32A | 45A | 50A | ||
AC Motor | 1P | 115V | 0.5HP | 0.5HP | 1HP | 2HP | 2HP | 3HP |
230V | 1HP | 2HP | 3HP | 3HP | 5HP | 5HP | ||
3P | 200V | 2HP | 3HP | 5HP | 7HP | 7.5HP | 10HP | |
230V | 2HP | 3HP | 5HP | 7.5HP | 10HP | 10HP | ||
460V | 5HP | 7.5HP | 10HP | 10HP | 20HP | 25HP | ||
575V | 7.5HP | 10HP | 15HP | 15HP | 20HP | 25HP | ||
Panel installation | Rail & screw | |||||||
External dimension(mm) | 44x80x86.8 | 68x82x94.6 | ||||||
Mounting dimension(mm) | 30~35x48~59
35x60 |
Mode | GMC-50 | GMC-65 | GMC-75 | GMC-85 | GMC-100 | GMC-125 | ||
IEC-60947 AC1 duty | 80A | 100A | 110A | 135A | 150A | 150A | ||
UL AC3 duty | 200-240V | 15KW 55A | 18.5KW 65A | 22KW 75A | 25KW 85A | 30KW 105A | 37KW 125A | |
380-440V | 22KW 50A | 30KW 65A | 37KW 75A | 45KW 85A | 55KW 105A | 60KW 120A | ||
500-550V | 30KW 43A | 37KW 60A | 45KW 64A | 45KW 75A | 55KW 85A | 60KW 90A | ||
690V | 30KW 33A | 37KW 47A | 45KW 47A | 45KW 52A | 55KW 65A | 60KW 70A | ||
Continuous current(th) | 70A | 80A | 90A | 100A | 160A | 160A | ||
AC Motor | 1P | 115V | 3HP | 5HP | 5HP | 7.5HP | 7.5HP | 10HP |
230V | 7.5HP | 10HP | 15HP | 15HP | 15HP | 20HP | ||
3P | 200V | 10HP | 15HP | 20HP | 25HP | 30HP | 40HP | |
230V | 15HP | 20HP | 25HP | 30HP | 30HP | 40HP | ||
460V | 30HP | 40HP | 50HP | 50HP | 60HP | 75HP | ||
575V | 30HP | 40HP | 50HP | 50HP | 60HP | 75HP | ||
Panel installation | Rail & screw | |||||||
External dimension(mm) | 94x123.5x117.4 | 100x157.4x146.5 | ||||||
Mounting dimension(mm) | 100x50~60
100x60 | 80x110
90x125 | 80x100
90x125 |
- Q: What is the difference between a contactor and a circuit breaker?
- Depending on the specific brand, model may be. Its sub-closing can be manually or electrically
- Q: What is the number of AC contactors?
- contact system, including three main contacts and one to two groups normally open, normally closed auxiliary
- Q: Research on Relay Parameter Detection Technology Based on Single Chip
- The cost of the device is high, which is of great reference value for the development of the test equipment. [2]
- Q: What are the principles of selection of contactors?
- When controlling the motor, the rated current of the main contact should be greater or slightly larger than the rated current of the motor
- Q: Current Status of Electrical Performance Testing Technology for Contactors
- the contact pressure drop, disconnect the contact between the voltage, the main circuit current and other electrical parameters of the sample sampling. The control part uses a digital I / O board to drive the contactor or relay on and off by controlling the solid state relay
- Q: A brief introduction to the power contactor
- AC contactor action power from the AC electromagnet, electromagnet by the two "mountain" shaped silicon steel sheet stacked
- Q: Traditional communication contactor long life and long reliability?
- especially the voltage, current, magnetic gap increases easily lead to heat and the coil burned, and permanent magnetic contact device is not possible to burn the coil.
- Q: What is the main component of the contactor?
- AC contactor contacts, made of silver tungsten alloy, with good conductivity and high temperature ablation
- Q: How to measure the contactor is good or bad
- Look: A, see if it works. B, boot, such as contactor pull, then the fan work, press does not work (set the capacitor is good), can initially determine the contactor bad
- Q: What are the types of AC contactors?
- arc extinguishing system: arc extinguishing device used to ensure that the contact disconnect the circuit, the arc generated by the reliable off to reduce the damage to the contact of the arc.
1. Manufacturer Overview
Location | Zhejiang,China (Mainland) |
Year Established | 1996 |
Annual Output Value | US$2.5 Million - US$5 Million |
Main Markets | 8.33% North America 8.33% South America 8.33% Eastern Europe 8.33% Southeast Asia 8.33% Africa 8.33% Oceania 8.33% Mid East 8.33% Eastern Asia 8.33% Western Europe 8.33% Central America 8.33% Northern Europe 8.33% Southern Europe |
Company Certifications | ISO 9001:2008;ISO 14001:2004;OHSAS 18001 |
2. Manufacturer Certificates
a) Certification Name | |
Range | |
Reference | |
Validity Period |
3. Manufacturer Capability
a) Trade Capacity | |
Nearest Port | |
Export Percentage | 31% - 40% |
No.of Employees in Trade Department | 3-5 People |
Language Spoken: | English |
b) Factory Information | |
Factory Size: | 30,000-50,000 square meters |
No. of Production Lines | 5 |
Contract Manufacturing | OEM Service Offered Design Service Offered Buyer Label Offered |
Product Price Range | High and/or Average |
Send your message to us
GMC-09,12,18,22 AC Contactor / GMC Series
- Loading Port:
- China Main Port
- Payment Terms:
- TT or LC
- Min Order Qty:
- 10 Pieces pc
- Supply Capability:
- 10,000 Pieces per Quarter pc/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches
Related keywords