Defrost Timer(Freezer Timer)
- Loading Port:
- China Main Port
- Payment Terms:
- TT or LC
- Min Order Qty:
- 1000 Pieces pc
- Supply Capability:
- 50000 Pieces per Month pc/month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
Defrost timer(freezer timer) is designed to control defrosting time for refrigerators, showcases, freezers,ice maker and so on.
Defrost timer(freezer timer) is applicable for controlling defrost timing in the refrigerating systems of the refrigerator and other freezer.Defrost timer( series) driven by mini-ACS(Alternating Current Synchronous) motors, good timing, little power consumption, low noise; high capacity switch design, better loading capacity; sophisticated structure, suitable for installing inside or outside .
Specification as below:
1.Ratings:AC100~127V 50/60Hz AC200~240V 50/60Hz
2.Insulation Resistance:≥100MΩ
3.Contact rated power:5A
3.Power:≤1.5W
4.Noise:≤30dB
5.Environmental conditions: Temperature -20 °C ~ 63 °C, relative humidity below 95%
6.Useful Life:≥250000
TIMETABLE
NO. | Prodiuct Model | Working Cycle Time | Defrost Time | ||
50Hz | 60Hz | 50Hz | 60Hz | ||
1 | TMDE-309 | 3hr40m | 3hr04m | 10m | 7m30s |
2 | TMDE-320 | 3hr41m | 3hr04m | 20m | 16m |
3 | TMDE-409 | 4hr | 3hr19m | 9m | 7m25s |
4 | TMDE-415 | 4hr | 3hr19m | 15m | 12m39s |
5 | TMDE-418A | 4hr50m | 4hr | 18m | 15m |
6 | TMDE-420 | 4hr | 3hr19m | 20m | 16m39s |
7 | TMDE-424A | 4hr50m | 4hr | 24m | 20m |
8 | TMDE-425 | 4hr | 3hr19m | 25m | 20m49s |
9 | TMDE-617 | 6hr1m | 5hr | 17m40s | 14m43s |
10 | TMDE-625 | 6hr2m | 5hr | 25m | 20m49s |
11 | TMDE-630 | 6hr2m | 5hr | 30m | 25m |
12 | TMDE-706 | 7hr54m | 6hr35m | 7m30s | 6m15s |
13 | TMDE-802 | 8hr46m | 7hr18m | 2m24s | 2m |
14 | TMDE-807 | 8hr1m | 6hr40m | 7m3s | 5m53s |
15 | TMDE-814 | 8hr | 6hr40m | 14m | 11m40s |
16 | TMDE-8030 | 8hr1m | 6hr40m | 30m | 25m |
17 | TMDE-909 | 9hr21m | 7hr48m | 9m | 7m30s |
18 | TMDE-1210 | 12hr06m | 10hr05m | 10m48s | 9m36s |
19 | TMDE-1211 | 12hr21m | 10hr18m | 10m48s | 9m36s |
20 | TMDE-1240 | 12hr06m | 10hr05m | 40m | 33m20s |
21 | TMDE-1302 | 13hr | 10hr50m | 2m24s | 2m |
22 | TMDE-1305 | 13hr | 10hr50m | 5m | 4m10s |
23 | TMDE-1310 | 13hr | 10hr50m | 10m48s | 9m |
24 | TMDE-1441 | 14hr26m | 12hr01m | 41m | 34m10s |
25 | TMDE-2415 | 24hr02m | 20hr01m | 15m | 12m |
- Q: What is the difference between a contactor and a circuit breaker?
- the main circuit breaker to do protection, its protection is currently more commonly used is the three sections of protection, both overload protection, short circuit short delay, short circuit long delay.
- Q: Judge the contactor is good or bad
- contact points on the dirt or moving iron core contact surface dirt. If you hear Kaka - contactor can not absorb the sound, mostly for two cases
- Q: The contactor is mainly composed
- The service life of the contactor is very high, the mechanical life is usually several million to ten million times, and the electrical life is generally several hundred thousand to several million times.
- Q: Use Star Triangle to start contactor's order and process method
- Coil power, its dynamic contact contact is broken, cut off the time relay coil circuit, so that time relay to stop working.
- Q: What is the formulation of the contactor?
- contactor number of auxiliary contacts, and contactor installation options
- Q: What is the scope of use of AC contactors?
- If there is self-locking control, according to the principle of the line on it. (Circuit diagram) connected to the three-phase motor This is the AC contactor control a three-phase motor typical circuit diagram, in addition, a boot button, a stop button
- Q: By the drive system, contact systems, arc and other components of the connector.
- usually contactor are equipped with arc extinguishing device, the general use of semi-sealed vertical seam clay hood, and with a strong magnetic blown arc.
- Q: The computer as a host computer
- operating voltage, contact resistance Electrical parameters for testing. In the test of the action time, the relay will be tested normally closed contact high, normally open contact ground
- Q: What are the classification of contactors?
- DC current compared with the AC current, there is no periodic current value of the zero-crossing point, so the traditional contactor breaking circuit, the contact between the arc is more intense
- Q: What is the effect of the contactor coil parallel capacitor?
- causing the surrounding electronic equipment, especially the PLC's electronic control equipment caused by interference, but also reduce the electrical life of the contacts.
1. Manufacturer Overview
Location | Zhejiang, China (Mainland) |
Year Established | 2000 |
Annual Output Value | US$1 Million - US$2.5 Million |
Main Markets | South America; Eastern Europe; Southeast Asia; Africa; Oceania; Mid East; Eastern Asia |
Company Certifications | TEST REPORT; TEST REPORT; TEST REPORT; CE certificate |
2. Manufacturer Certificates
a) Certification Name | |
Range | |
Reference | |
Validity Period |
3. Manufacturer Capability
a) Trade Capacity | |
Nearest Port | Ningbo, Shanghai |
Export Percentage | 51% - 60% |
No.of Employees in Trade Department | 3-5 People |
Language Spoken: | English, Chinese |
b) Factory Information | |
Factory Size: | 3,000-5,000 square meters |
No. of Production Lines | 3 |
Contract Manufacturing | OEM Service Offered Design Service Offered |
Product Price Range |
Send your message to us
Defrost Timer(Freezer Timer)
- Loading Port:
- China Main Port
- Payment Terms:
- TT or LC
- Min Order Qty:
- 1000 Pieces pc
- Supply Capability:
- 50000 Pieces per Month pc/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches
Related keywords