1. Parameter: |
| ||||||||||||||||||||||||
Xuejing Series Model: | |||||||||||||||||||||||||
LED FL-16W-F3-XJ | 88 LED/1200 MM | ||||||||||||||||||||||||
Input Voltage (V): | AC 180-260V | ||||||||||||||||||||||||
Power (W) : | 16W | ||||||||||||||||||||||||
Current (A) | 0.14A | ||||||||||||||||||||||||
Degree of Protection (IP) : | IP20 | ||||||||||||||||||||||||
Material : | SMD 3528 | ||||||||||||||||||||||||
Max. Op. Temp. : | 40℃ | ||||||||||||||||||||||||
Ambient Temp. : | -10℃-40℃ | ||||||||||||||||||||||||
Ambient Humidity : | 35% | ||||||||||||||||||||||||
Power Factor : | 0.6 | ||||||||||||||||||||||||
LED Luminous Flux (lm) : | 1550lm | ||||||||||||||||||||||||
Beam Angle (degrees) : | 320° | ||||||||||||||||||||||||
Luminous Efficacy (lm/watt) : | 90 | ||||||||||||||||||||||||
Color Rendering Index (Ra) : | 72 | ||||||||||||||||||||||||
Average Life (hours) : | 20000 | ||||||||||||||||||||||||
Lamp Body Material : | Glass | ||||||||||||||||||||||||
Lamp Holder: | G13 | ||||||||||||||||||||||||
Size (diameter): | Ø26 | ||||||||||||||||||||||||
Power : | Built-in Isolating Source | ||||||||||||||||||||||||
Driver Model: | Constant Current Driver | ||||||||||||||||||||||||
Color and Colour Temperature: | White 6500K , Warm White 3000K | ||||||||||||||||||||||||
Spec. | A Max(mm) | B Max(mm) | B Min(mm) | C Max(mm) | Ø (mm) | ||||||||||||||||||||
LED FL-16W-F3-XJ | 1199.4 | 1206.5 | 1204.1 | 1213.6 | 26 | ||||||||||||||||||||
5. Key Specifications/Special Features: | |||||||||||||||||||||||||
Features: | |||||||||||||||||||||||||
1) LED tube integrates a LED light source into a traditional fluorescent form factor | |||||||||||||||||||||||||
2) Its unique design creates a perfectly uniform visual appearance, which cannot be distinguished from traditional fluorescent tube light | |||||||||||||||||||||||||
3) This product is the ideal solution for up lamp in general lighting applications | |||||||||||||||||||||||||
4) The LED tube is an affordable LED solution suitable for replacing T8 fluorescent lamps | |||||||||||||||||||||||||
5) The product provides a natural lighting effect for use in general lighting applications, as well as instant energy-saving, an eco-friendly solution | |||||||||||||||||||||||||
6) Designed to replace fluorescent T8 tubes, the LED T8 offers an incredible lighting performance that reduces both electricity and maintenance costs | |||||||||||||||||||||||||
7) With the long lamp lifespan and wide range of operating temperature, it is ideal for applications such as offices, warehouses, car parking, factories and kitchens | |||||||||||||||||||||||||
6. Benefits: | |||||||||||||||||||||||||
1) Direct replacement retrofit for fluorescent T8 tubes at much low-energy consumption | |||||||||||||||||||||||||
2) For retrofit on conventional magnetic ballast circuits by simply exchanging the starter in the installation with the dummy start supplied with the tube | |||||||||||||||||||||||||
3) Excellent heat-dissipation | |||||||||||||||||||||||||
4) No buzzing noise, fluorescent flickering and RF interference | |||||||||||||||||||||||||
5) Eliminates dark regions at both end of the T8 tube | |||||||||||||||||||||||||
6) High-lumen maintenance | |||||||||||||||||||||||||
7. Installation Instruction | |||||||||||||||||||||||||
| |||||||||||||||||||||||||
8. INSTALLATION DIRECTIONS: | |||||||||||||||||||||||||
1. Before installation, please read instruction carefully and preserve it well. | |||||||||||||||||||||||||
2. Only maintained and installed by qualified electrician. | |||||||||||||||||||||||||
3. Before installation, please cut off the main power. | |||||||||||||||||||||||||
4. Do not connect the lamp to main supply until installation is completed. | |||||||||||||||||||||||||
5. Please DON’T USE LED TUBES with BALLASTS and STARTERS. | |||||||||||||||||||||||||
6. Please follow the Connection Schema for correct connection. Make sure the appliance has been mounted safely. | |||||||||||||||||||||||||
9. CAUTION: | |||||||||||||||||||||||||
1. Turn off the switch when replacing and cleaning. | |||||||||||||||||||||||||
2. Wipe lamp with a dry duster. | |||||||||||||||||||||||||
3. Do not use any chemical duster or solvent such as oil or thinner. | |||||||||||||||||||||||||
4. Do not spray insecticide on this lamp. |
- Q: I hope my answer will help you
- Rotate it, or you can move the tube to the right and try it.I hope my answer will help you.
- Q: In several production workshops of my unit, we will replace a batch of philips T5 fluorescent fluorescent lamps with LED fluorescent lamps. However, it took more than two years to get rid of the old lamp, and it was neither green nor economical, so consult the high man.
- If directly the trash, they directly of fate is crowded broken last school in trichromatic lamp, hundreds of root powder halogen bulbs all into the trash can, garbage, directly sent to the car, and then crushed, hundreds of light tube is less than half a minute into a pile of white powder, some still have a few days of the new tubes Two head didn't black.
- Q: Leds are the ones that are brightest
- The full plastic tube (aluminum) > glass tube > half plastic half aluminum is recommended. The glass tube is fragile and is restricted in use.
- Q: How does the traditional daylight lamp tube replace the LED light tube?
- You don't have to change any of the lines, you have to remove all of the fluorescent lights, you just leave two lines, and then you connect the two ends of the LED lights
- Q: Feasibility analysis report of LED lamps
- With the advent of ultra bright white leds, applications in lighting have become possible. According to the international authorities, the 21st century will enter the era of new lighting, which is represented by leds, and is called a fourth generation new light source. At present, the lighting consumption accounts for about 20% of the whole power consumption, reduce lighting electricity is an important way to save energy, in order to achieve the goal of the industry have developed many kinds of energy-efficient lighting apparatus, and achieved certain results. However, the requirement of "green lighting" is not enough, and it is imperative to develop and apply a new source of efficiency, reliability, safety and durability. LED with its inherent superiority is attracting the world's attention. According to the forecast the U.S. department of energy (doe), around 2010, the United States will have 55% of incandescent lamp and fluorescent lamp is replaced by LED, power saving value of up to 35 billion dollars a year, may become a $50 billion industry. Japan suggested that leds would replace traditional incandescent lamps in 2006. LED development history has for decades, but the application in the field of lighting and new technology, but with the rapid development of LED technology, gradually improve the luminous efficiency, LED the market will be more widely used, especially in the rising again under the background of global energy shortage, the LED in lighting market prospect is more highly attention around the world, is considered by the industry in the next 10 years to become the most promising markets, as well as the biggest markets will be replace incandescent lamp, the greatest potential for tungsten filament lamp and fluorescent lamp.
- Q: Is there a greater value in switching from a normal daylight lamp to an LED energy-saving lamp?
- I can give you a detailed example of your problem: LED fluorescent lamp tube 6w can replace the normal daylight lamp tube 20w, 9w can replace 30w, 12w can replace 40w, 15W replace 45W, 18w can replace 60w, save more than 70% electricity; LED life can theoretically reach 5-100,000 hours, nearly 10 years. Q: how much electricity do you need a year if your company owns 10,000 40W, regular daylight bulbs (plus a rectifier, for example, 46-49 watts)? A: common light bulb: 365 days * 15 hours * 46w * 10,000 lamp tube / 1000W (1 hour) * charge 1 yuan = 2518500 yuan. LED bulbs: 365 days * 15 hours * 12W * 10,000 tubes / 1000W (1 hour) * charge 1 yuan/degree = 657,000 yuan. On the data, the cost can be recouped within a year, saving as much as $3 million in electricity bills within three years.
- Q: LED T5 T8 and normal fluorescent lamps with no ballast
- A 16W LED fluorescent lamp, equivalent to 40W of ordinary fluorescent lights!
- Q: How do fluorescent tubes clean
- Use damp and wet towel to wipe to be able, pay attention to want to turn off the power, lest electric shock!
- Q: The ledt8 lamp is used for the light bulb
- Generally see you want how much wattage T8 tubes, according to how much wattage to order the lamp bead, generally a lamp bead is 0.5 w, according to the wattage calculate knew how many light bead
- Q: Can the T5 light tube be free of ballast?
- Your home is T4, but there's a rectifier on both sides.I hope my answer is useful to you.
Send your message to us
T8 LED glass tube,16W, 88leds/1200mm, 1550lm, SMD3528,G13,Ø26, AC180-260V,Constant current driver, White6500K,Warm white3000K,CE
- Loading Port:
- China Main Port
- Payment Terms:
- TT OR LC
- Min Order Qty:
- -
- Supply Capability:
- -
OKorder Service Pledge
Quality Product, Order Online Tracking, Timely Delivery
OKorder Financial Service
Credit Rating, Credit Services, Credit Purchasing
Similar products
Hot products
Hot Searches