• T8 LED glass tube, 13W, 68leds/900mm, 1150lm, SMD3528,G13,Ø26, AC180-260V,Constant current driver, White6500K,Warm white3000K,CE System 1
  • T8 LED glass tube, 13W, 68leds/900mm, 1150lm, SMD3528,G13,Ø26, AC180-260V,Constant current driver, White6500K,Warm white3000K,CE System 2
  • T8 LED glass tube, 13W, 68leds/900mm, 1150lm, SMD3528,G13,Ø26, AC180-260V,Constant current driver, White6500K,Warm white3000K,CE System 3
T8 LED glass tube, 13W, 68leds/900mm, 1150lm, SMD3528,G13,Ø26, AC180-260V,Constant current driver, White6500K,Warm white3000K,CE

T8 LED glass tube, 13W, 68leds/900mm, 1150lm, SMD3528,G13,Ø26, AC180-260V,Constant current driver, White6500K,Warm white3000K,CE

Ref Price:
get latest price
Loading Port:
China Main Port
Payment Terms:
TT OR LC
Min Order Qty:
-
Supply Capability:
-

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing
T8 LED GLASS TUBE





1. Parameter:









 





Haoyue Series Model: 




LED FL-13W-F3-HY68 LED/900 MM




 




Input Voltage  (V):AC 180-260V




Power (W) :13W




Current (A)0.12A




Degree of  Protection (IP) :IP20




Material :SMD 3528




Max. Op. Temp.  :40℃




Ambient Temp.  :-10℃-40℃




Ambient  Humidity :35%




Power Factor :0.6




LED Luminous  Flux (lm) :1150lm




Beam Angle  (degrees) :320°




Luminous  Efficacy (lm/watt) :85




Color  Rendering Index (Ra) :72




Average Life  (hours) :20000




Lamp Body  Material :Glass




Lamp Holder:G13




Size  (diameter):Ø26




Power :Built-in  Isolating Source 



Driver Model:Constant Current  Driver




Color and  Colour Temperature:White 6500K , Warm White   3000K


















Spec.A    Max(mm)B     Max(mm)B     Min(mm) C    Max(mm)Ø               (mm)
LED FL-13W-F3-HY894.6901.7  899.3  908.8  26








5. Key  Specifications/Special Features:

Features:

1) LED tube  integrates a LED light source into a traditional fluorescent form factor

2) Its unique design creates a perfectly uniform visual  appearance, which cannot be distinguished from traditional fluorescent tube  light

3) This product is  the ideal solution for up lamp in general lighting applications

4) The LED tube is  an affordable LED solution suitable for replacing T8 fluorescent lamps

5) The product provides a natural lighting effect for use in  general lighting applications, as well as instant energy-saving, an  eco-friendly solution

6) Designed to replace fluorescent T8 tubes, the LED T8 offers  an incredible lighting performance that reduces both electricity and  maintenance costs

7) With the long lamp lifespan and wide range of operating  temperature, it is ideal for applications such as offices, warehouses, car  parking, factories and kitchens








6.  Benefits:

1) Direct  replacement retrofit for fluorescent T8 tubes at much low-energy consumption

2) For retrofit on conventional magnetic ballast circuits by  simply exchanging the starter in the installation with the dummy start  supplied with the tube

3) Excellent  heat-dissipation

4) No buzzing  noise, fluorescent flickering and RF interference

5) Eliminates dark  regions at both end of the T8 tube

6) High-lumen  maintenance















7. Installation Instruction


















 






















































































































































































8.  INSTALLATION DIRECTIONS:




1. Before installation, please read instruction carefully and  preserve it well.
2. Only maintained and installed by qualified electrician.
3. Before installation, please cut off the main power.
4. Do not connect the lamp to main supply until installation is  completed.
5. Please DON’T USE LED TUBES with BALLASTS and STARTERS.
6. Please follow the Connection Schema for correct connection.  Make sure the appliance has been mounted safely.







9. CAUTION:      
1. Turn off the switch when replacing and cleaning.
2. Wipe lamp with a dry duster.
3. Do not use any chemical duster or solvent such as oil or  thinner.
4. Do not spray insecticide on this lamp.



Q: Are led fluorescent tubes not available for lighting?
If home have a stent is built-in LED lights to be the most is to take the rectifier, and the external power supply is to use the power of the manufacturer to provide, so to be more back to safe some more energy efficient, at the same time LED the longer service life
Q: The lighting is replaced by LED lights and circuit problems
My home is a branch. The whole thing is broken even the base is changed, the base is to take the shock drill to drill in the wall, my home has no impact electric drill. The part of the branch is just changing the daylight lamp. Save trouble. The first time I took the regenerator and the ballast down, I had a makeover. You just need to put the fluorescent tube directly on it. Very simple.
Q: Selling LED T5 T8 fluorescent tube How do I seek customers search on the net, want to make a phone call don't know how to find customers or even who call) say specific point!!
I'm also feeling the market is uncertain.What brand or company do you do.
Q: How to detect the good and bad of the fluorescent lamp
If you measure the resistance at both ends, it's not bad
Q: Why is it that when my electric car is charged, the light bulb is burning in the house, and the incandescent lamp is fine, and the other appliances are normal
It is possible that the high frequency pulse of the charger inside the charger is flowing into the power grid, causing the fluorescent lamp ballast to work and burn down. Electric car charger belongs to the circuit structure of the switching power supply, and the internal vibration circuit is used to produce high frequency signal to drive the transformer. Check to see if the interconnection filter and capacitance component of the inner power source of the charger are damaged. The fluorescent lamp ballast is part of the half-bridge inverter circuit, which is more easily disturbed.
Q: Is there any LED fluorescent lamp that can be used for more than five years?
Currently, there is no such thing as civilian use for 3-5 years, but the commercial is still below that level.
Q: Do the fluorescent tubes save electricity for 10 minutes, or do they save electricity in a split second?
Although the data is missing, the electric current of the opening is larger and the power consumption is no more than 10 minutes
Q: LED T5 T8 and normal fluorescent lamps with no ballast
Say something practical, high brightness LED, energy saving, but there is light, if you are not willing to spend money to buy things, light failure will be very serious, fixtures are usually carry an umbrella the double tube is 20-30 yuan, tubes T5led18W market price has 40 - XXX, basically see the quality stand or fall, philips lamp wholesale is 5 yuan, fluorescent lamp with ballast, points electronic with inductance, the inductance of the durable, but noisy, electronic not durable but little noise, hand to hope to adopt
Q: What is the 1.5-meter LEDT5 daylight lamp tube
In my experience, it should be industrial purposes, such as 1.2 meters tubes the effective length of exposure is not enough, but with a price on the high side, will have a 1.5 meters east east.
Q: How did the new daylight tube ring
Gas rolling phenomenon, low temperature.I hope my answer will help you.

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

Hot products


Hot Searches