Single-core Cable PV-1x4.0mm² made in China
- Loading Port:
- Shanghai
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 0 m
- Supply Capability:
- 30000000 m/month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
Description of Single-core Cable
Single core refers to only have a conductor in an insulating layer. When more than 35 kv voltage, most of the single-core cable, the wire core and the relationship between the metal shielding layer, can be seen as a transformer coils in the primary winding and iron core. When a single core cable core in current will have lines/aluminum package or metal shielding layer, make it appear at both ends of the induced voltage.
Main Features of Single-core Cable
Dual wall insulation, Electron beam cross-linked
Excellent resistance to UV,water,ozone,fluids,salt,general weathering
Excellent resistance to abrasion
Halogen free, flame,ratardant,low toxicity
Excellent flexibility and stripping performance
High current carrying capacity
TUV and UL approved
Specifications of Single-core Cable
TYPE | Cross section | Strand design | Conductor diameter | Conductor resistance | Outer diameter | Rated voltage | Rated current |
mm² | NO.xФ(mm) | mm | Ω/Km | mm | VAC/DC | A | |
PV-1x4.0mm² | 4.0 | 56.xФ0.3 | 2.6 | 4.97 | 6.2 | 1000/1800 | 50 |
Technical Data of Single-core Cable
Wire:Class5 tinned
Insulation material: XLPE
Double insulated
Halogen-free
HIgh resistance against oils, greases,oxygen and ozone
Microbe-resistant
UV resistant
High wear and abrasion resistance
Flame test according to :DIN EN 50265-2-1 UL 1571(VW-1)
Smallest permissible Bending Radlus 5xD
Temperature range -40℃~+90℃
Colours: Black Red
IMages of Single-core Cable
FAQ:
① why from okorder?
Okorder is a qualified supplier of all kinds of building matierials in China. All products have been showed in Okorder website are under well controlled by okorder QC team.
All products had been produced under a clear quality standard and the quality is consistence among the shipments.
Okorder has already setted up more than 20 warehouses in different markets to show the products. You are convenient to know the products from your local place and it will help you to make decision easyly.
②How to guarantee the quality of the products?
We have established a perfect quality management system,as for raw material and semi parts all are under strict quality test and we have a IQC system to control the purchases.
QC on site is very strict and all steps of process are measured per drawings. Before delivery, we set a OQC system to make sure each piece meet the standard of order.from design to delivery,
③How long can we receive the product after purchase?
Lead time depending on order quanity, The normal order can be deliveried with 3 weeks.
- Q:What are the varieties of wire and cable (detailed point)
- Cable regardless of the definition of the number of elements in the definition of a few such as: YJV-3 * 50 + 1 * 16 calculated the number of lines is always a different, different wire rules Model input: bv-2 * 2.5 / bv-3 * 4 (different material), bv-2 * 2.5 + 3 * 4 (the same material)
- Q:What machinery is required to make wire and cable?
- Pouring concrete when you can line? Do you clear the problem?
- Q:This cable or accessory has not been certified and may not be able to work with this iphone reliably
- The installation process is a certain requirement, high and low voltage cable bridge should be installed separately as usual, a wall laying vertical pipeline (slot) or installation equipment, the power distribution between the depth of D1 = 1200 ~ 1500mm; weak Between the deep distance from the D2 = 1100 ~ 1400mm more reasonable. The length L1 and L2 between the power distribution and the weak can be determined according to how much electrical equipment and pipelines (slots) are installed in the room. "Civil building electrical design specifications" proposed "shaft size in addition to meet the wiring spacing and terminal box, distribution box layout must be the size, but also in the box before the left not less than 0.8m operation, maintenance distance" requirements. In the weak equipment, the operation and maintenance distance is not specified in the provisions of the Code for Electrical Design of Civil Buildings, but it should not be less than 0.8m. Cable to wear steel pipe wiring, should be reserved in the floor steel pipe, wiring should be completed after the plug fire fire blocking material. Cable bridge installation should be horizontal, the maximum sag should not be greater than 10 mm; proposed separate installation
- Q:IPhone mobile phone data cable can not charge the power, the above shows the cable or accessories not certified can not work with the iPhone,
- Not allowed to slot the proposal with PVC gusset which is only 1 cm thick only open protective layer on it! The water pipe is not enough unless you have a thickened wall outside the decoration.
- Q:Apple 6 Charging Why always show this cable has not yet been certified
- Cable and cable distinction In fact, "wire" and "cable" and there is no strict boundaries
- Q:Four lines only reached a phase line, at the other end all charged, I use the digital pen! In addition, I often check the cable when the cable current through the dot digital pen voltage symbols sometimes have time to disappear, in other bare wires when the test keys are normal! What is this going on! Ask the heroes to give the younger brother a complete point of the answer! More
- Bookstore tool book should have "communication project budget", I do is what you say, the budget is divided into estimates and budget, is two steps. So that is not very clear. But what is needed is the preliminary design of the project. The budget is needed for design and drawings. Internal management of this piece, the main thing is that you need to do what the project department, and are generally very complicated
- Q:Apple 6splus charge may not support this accessories how to do more
- 5 small cable, if you feel high cost Can be from the distribution box to the circuit The first light using a small cable low-voltage bus to the equipment side, due to the power distribution room to the equipment side will appear more climbing, bus installation climbing very troublesome and affect the beautiful, The bus outlet cabinet uses cables and installs the transfer box on the busbar
- Q:Rt, the charger did not change, has been no problem before, today just plugged into the charger, the results appear as if the problem, before the out of this problem, and now only ipad power off after the power can not be charged, and ipad start , Then immediately prompted the title, can not charge more
- The proportion of the cross-sectional area of the cable through the embedded pipe is 20%
- Q:Why this cable has not yet been certified
- Electromechanical products are usually used to be assembled into parts, multiple parts and then assembled into a single product, the number of products or the number of pieces measured
- Q:Apple mobile phone does not support this charge when charging this thing how to charge
- Yes, it is more conducive to the protection of the battery, but if no power out of power, the data can not be saved ah, and you have to put the battery on a regular charge
1. Manufacturer Overview |
|
---|---|
Location | |
Year Established | |
Annual Output Value | |
Main Markets | |
Company Certifications |
2. Manufacturer Certificates |
|
---|---|
a) Certification Name | |
Range | |
Reference | |
Validity Period |
3. Manufacturer Capability |
|
---|---|
a)Trade Capacity | |
Nearest Port | |
Export Percentage | |
No.of Employees in Trade Department | |
Language Spoken: | |
b)Factory Information | |
Factory Size: | |
No. of Production Lines | |
Contract Manufacturing | |
Product Price Range |
Send your message to us
Single-core Cable PV-1x4.0mm² made in China
- Loading Port:
- Shanghai
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 0 m
- Supply Capability:
- 30000000 m/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches