Set Screw EMT Connector -ZINC ,American Standard, NPT Thread
- Loading Port:
- Ningbo
- Payment Terms:
- TT or LC
- Min Order Qty:
- 1000 pc
- Supply Capability:
- 300000 pc/month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
EMT Connector
American Standard, NPT Thread
UL Standard 514B
Size: Zinc 1/2" to 4"
Aluminum 1/2" to 2"
Material: Zinc/Aluminum Die Cast
Description:
EMT connectors are used in dry locations to bond EMT conduit to electrical junction boxes or enclosures. EMT connectors provide concrete tight connections when taped and properly secured with the included locknut, and are rated for electrical applications above 600 volts. Their heavy gauge steel construction maintains mechanical protection and solid grounding of the conduit to the designated electrical junction box or enclosure.
Applications:
EMT connector: Joins steel EMT conduit to Electrical box
•Connect & effectively bond EMT conduit to steel outlet boxes, load centers & other metal enclosures
•May be used indoors and in concrete-tight applications when taped
•Body and locknut made with die-cast zinc alloy
•Tri-Drive screw head design for use with Phillips, slotted and square screwdrivers
•Screw thread is designed to not vibrate loose
•Reversible locknut designed to cut through protective coatings on boxes & enclosures
•UL standard for safety
•Application type : EMT
•Electrical Product Type : Standard Fitting
•Fitting type : Connector
•Indoor/Outdoor : Indoor
•Paintable/Stainable : No
•Returnable : 90-Day
•Trade Size (in.) : [1/2"] [3/4"] [1"] [1-1/4"] [1-1/2"] [2"]
Competitive Advantage:
+Quick Delivery: 30 days for one 20ft container.
+Competitive Price
+ Good Quality: ISO/UL certificate approval
+Best Service: fast delivery, strong package, good price, timely and effective communication
+Powerful Solution: fast and effective solution to problem
- Q: 1000 kW 600 m cable to use much
- 1000kw ah that with three groups of 400-ping line should be no problem
- Q: Is the cable head made of every building?
- First, the cable production and installation of each building has. Second, the cable terminal set of waterproof, stress control, shielding, insulation in one, with good electrical and mechanical properties, in a variety of harsh environmental conditions for long-term use. With the advantages of light weight, easy installation and so on. Cable terminal is widely used in electric power, petrochemical, metallurgy, railway ports and construction and other fields. Third, the production process: including the following: . cut off the excess cable; . the cable protective layer of the stripping; . conductor connection; . wrapped around insulation (or shrink pipe); . install the connector shell; . ; . for sealing treatment.
- Q: 3 by 16 cable is a few flat? How? That 5 by 16?
- Motherboard and power supply problem, the best way is to try to USB2.0 ban on the use of USB1.1 but will be slower
- Q: How much of the cable with the switch?
- The switch is not selected according to the cable and is selected according to the current. The cable is determined by the size of the power (converted to current) and the distance from which the distance is far. The greater the power distance, the greater the cross-sectional area of the required cable. For example: 15KW motor selection cable current I = P / 1.732UcosΦ = 15 / 1.732 / 0.38 / 0.8 = 28A if it is close (within tens of meters), copper cable 6 square millimeters, aluminum cable 10 square millimeters. If it is in the distance (a few hundred meters), copper cable 10 square millimeters, aluminum cable 16 square millimeters. If it is long distance (close to kilometers), copper cable 16 square millimeters, aluminum cable 25 square millimeters. The switch is regardless of distance, completely based on the load current to choose, generally according to the load current of 1.5 times to 2 times to choose.
- Q: Does anyone know the "line buckle" classification (including shape / size / material / has been some commonly used size!) Line deduction is a hardware products! For daily necessities!
- If you want to ensure that the transmission medium does not cause the signal to cause attenuation and interference, fiber transmission or balanced cable transmission is the best solution. If you need fiber transmission, the cost is high because you need to buy digital fiber converters and digital audio decoders and related equipment, but this can be to the maximum extent to ensure the integrity of the signal and the smallest noise interference. If you want to use low-cost transmission can also be used directly to the cable transmission, but must use a balanced interface for transmission, and with 2-core shield or 3-core, 5-core shielded cable for transmission. This can also ensure the clarity of the signal to the maximum extent, but do not eat hungry thirsty 丨 Chicken check blood sausage is too long. No matter how good the cable will be attenuated, the size of the attenuation will directly affect the signal quality and signal integrity. So the transmission distance with the balance line can not be too far. More than two kinds of transmission methods than the existing single-line transmission is much better, if you are a fever-level players, I suggest you use fiber transmission. But if your power amplifier or your source signal to noise ratio is not high, I do not recommend you use fiber transmission, because even if the quality of fiber transmission no matter how good your source is not high, then it does not make sense The
- Q: 5 air conditioning can be used 4 square cable
- Such as the extension line added to the adapter primary (city side) certainly easy to use. Extended by two meters, the router does not start, may be extended wire diameter is too thin, bold wire try. If not, choose 6V2A adapter try, the voltage is too high will burn the router. Increase the current is no problem, just like the computer's power, 300-watt power can be replaced, and small is not OK.
- Q: The difference between nylon balls and geese and ducks
- If the 2.5 square copper wire for the output extension cable, 20 meters distance, the total resistance of about 2 * 1.7 * 0.2 / 2.5 = 0.272 (ohms), the current maximum 1.8A, the voltage drop is 0.272 * 1.8 = ), The charging voltage is 55-0.5 = 54.5 (volts), a difference of about 1% will not have any impact on the battery. However, the third floor, said Ye Hao, you can put the charger put the debris room, from your house put a 220V power cord down, home and then engage in a switch control. It is best to design a light at home, can intuitively see if the electricity is full. That's better. Design light, teach you a way: to find a bad leakless protector, open there is a coil-like ring-shaped stuff, called zero sequence current transformer, it will be down, be careful, do not put Transformers inside the coil hurt, get down, in the transformer two thin lines connected to a light-emitting diode. And then your 220V power cord line of fire from the center of the sensor through, around 3-5 turns. In this way, as long as there is current flow, the light-emitting diode will be bright, when the charge is over, the charging current is close to zero, the light-emitting diode will be extinguished. You can from the light-emitting diode is lit to determine whether the electric has been filled. I also have an electric bike that is so charged.
- Q: How do I ask for cable prices? How many tons is one or more?
- Cable bridge grounding should belong to the protective grounding, grounding resistance at a cross point is not greater than 50 milliohms, no jumper no more than 5 milliohms
- Q: 6 square cable up to how many air conditioning (1.5P)
- 1 square millimeters can flow 4A current, 1KW380V, then the current is about P = UI about 2.6A7KW, 380V, then the current is about 18A, each with the line to share 18/3 = 6A2.5 square mm of copper on it. Of the area need to take . probably 6 level. V is probably 7KW220VI = p / u = 7000/220 = 31A. Then need 10 square millimeters of copper.
- Q: 25 square copper cable how much money one meter?
- 3000w electrical work at 220V voltage is about 13.6A (current = power divided by voltage). Copper core line of the working current is generally a square 4-6A. That is to say you use 3-4 square power cord more secure.
Send your message to us
Set Screw EMT Connector -ZINC ,American Standard, NPT Thread
- Loading Port:
- Ningbo
- Payment Terms:
- TT or LC
- Min Order Qty:
- 1000 pc
- Supply Capability:
- 300000 pc/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches
Related keywords