Set Screw EMT Connector -ZINC ,American Standard, NPT Thread
- Loading Port:
- Ningbo
- Payment Terms:
- TT or LC
- Min Order Qty:
- 1000 pc
- Supply Capability:
- 300000 pc/month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
EMT Connector
American Standard, NPT Thread
UL Standard 514B
Size: Zinc 1/2" to 4"
Aluminum 1/2" to 2"
Material: Zinc/Aluminum Die Cast
Description:
EMT connectors are used in dry locations to bond EMT conduit to electrical junction boxes or enclosures. EMT connectors provide concrete tight connections when taped and properly secured with the included locknut, and are rated for electrical applications above 600 volts. Their heavy gauge steel construction maintains mechanical protection and solid grounding of the conduit to the designated electrical junction box or enclosure.
Applications:
EMT connector: Joins steel EMT conduit to Electrical box
•Connect & effectively bond EMT conduit to steel outlet boxes, load centers & other metal enclosures
•May be used indoors and in concrete-tight applications when taped
•Body and locknut made with die-cast zinc alloy
•Tri-Drive screw head design for use with Phillips, slotted and square screwdrivers
•Screw thread is designed to not vibrate loose
•Reversible locknut designed to cut through protective coatings on boxes & enclosures
•UL standard for safety
•Application type : EMT
•Electrical Product Type : Standard Fitting
•Fitting type : Connector
•Indoor/Outdoor : Indoor
•Paintable/Stainable : No
•Returnable : 90-Day
•Trade Size (in.) : [1/2"] [3/4"] [1"] [1-1/4"] [1-1/2"] [2"]
Competitive Advantage:
+Quick Delivery: 30 days for one 20ft container.
+Competitive Price
+ Good Quality: ISO/UL certificate approval
+Best Service: fast delivery, strong package, good price, timely and effective communication
+Powerful Solution: fast and effective solution to problem
- Q: 1000 kW 600 m cable to use much
- Depends on the load is emotional, resistive, should be too long cable, consider the pressure drop. Generally consider 2.5 or more.
- Q: Is the cable head made of every building?
- Building in accordance with the floor or unit configuration distribution box, there are office buildings using a total box. Where there is a cable out of the situation, must be wrapped to make the cable head, according to the choice of distribution box circuit breaker wiring crimp or not crimp the cable terminal. In other words, the cable head must be made, but not necessarily crimp the cable terminal.
- Q: What is the meaning of PG + digital markings for electrical wiring?
- Will the general power cable control cable can do the largest square...
- Q: 3 by 16 cable is a few flat? How? That 5 by 16?
- Motherboard and power supply problem, the best way is to try to USB2.0 ban on the use of USB1.1 but will be slower
- Q: How much of the cable with the switch?
- The switch is selected according to the current. General switch = (2-2.5) Current three-phase current = P / 1.732 / 0.38 / 0.8 Single-phase current = P / 0.22 / 0.8
- Q: 5 air conditioning can be used 4 square cable
- Lengthened low voltage side, the line resistance increases, the voltage drop increases. Reduced load capacity. So that the router due to insufficient supply voltage and can not work properly. It is not allowed to use 9V power supply. Voltage is too high, the router part of the internal power supply increased power, heat increased, it is possible to burn the router. It is necessary to extend the power cord, I suggest you extend the power supply side (220V one end) safe and reliable. Increase the voltage to increase the supply current, in the electrical working voltage range (with the electrical work voltage range) is allowed, too low electrical appliances can not work properly. Too high there is the risk of burning appliances, according to your actual situation, marked 5V0.2A that the router works at rated voltage, so the way to improve the supply voltage is not applicable. So you can only improve the power supply power (that is, you say to increase the power supply current rather than voltage). With the reserve power, it will provide enough current at the rated voltage (the router as a resistor, from I = U / R, you can know the danger of increasing the voltage) need help please message
- Q: The difference between nylon balls and geese and ducks
- It depends on the thickness of the wires you use. The thicker the copper wire is, the better. Because the distance will be a voltage drop. So be it, you use a multimeter to look at how long you charge when the output voltage is how much. If you can more than 50 should be no problem. If the voltage is relatively low can change a rough wire, or find a few wires in parallel can also be. I do not know if you can understand it. Even if there is a voltage drop if it is not very powerful should not be the problem, the worst result is the battery charge dissatisfaction. You can try to see how the effect of the day. Certainly will not break your equipment and battery, rest assured it
- Q: How do I ask for cable prices? How many tons is one or more?
- Yellow line is video, red and white are audio, you can only pick one!
- Q: 6 square cable up to how many air conditioning (1.5P)
- 7 kilowatts of electricity with what specifications of the wire if it is single-phase 220V, then 7 kilowatts of current is 7000 × 220V = 31.8A, check the electrical manual 4 square copper wire interception is 33A, to meet the requirements.
- Q: 25 square copper cable how much money one meter?
- There is no 1..2..4.5 square wire. The family uses most of the four wires with 1.. 1.. 2.5 and 4. Power 1KW Approx. 5A.3KW Approx. 15A.2.5 square copper wire can be used. Plug or empty open (25A).
Send your message to us
Set Screw EMT Connector -ZINC ,American Standard, NPT Thread
- Loading Port:
- Ningbo
- Payment Terms:
- TT or LC
- Min Order Qty:
- 1000 pc
- Supply Capability:
- 300000 pc/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches
Related keywords