• Copper Crimping Terminals with Nylon System 1
  • Copper Crimping Terminals with Nylon System 2
  • Copper Crimping Terminals with Nylon System 3
Copper Crimping Terminals with Nylon

Copper Crimping Terminals with Nylon

Ref Price:
get latest price
Loading Port:
China Main Port
Payment Terms:
TT or LC
Min Order Qty:
1000 Pieces pc
Supply Capability:
10000 Pieces per Day or more pc/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

Detailed Product Description

 

1 material:copper

 

2 nsulation:nylon

 

3 color:red,blue,yellow

 

4 plating:tin

 

5 UL certificated

 

6 wire range:

0.5 -1.5 mm2 / 22-16 AWG red
1.5 -2.5 mm2 / 16-14 AWG blue
4 -6 mm2 / 10-12 AWG yellow

                

7 maximum electric rating:150degree 600V

 

8 small orders are welcome

 

 

Feature:

 

1.We are glad to makes samples according to our customers'drawing,specifications and samples.

2.OEM is available.

3.Free to contact us,we can offer you the best service,top-quality goods,competitive price and timely delivery.

4.Our products are extensively used in electronic and other industries.

5.We have got the certificate ISO9001:2008 and TS16949.

 

Why choose us?
1.we have our team for work,own mould workshop.
2.The production can be made accurate by your design and demand.
3.Keep on line every day.
4.Perface package according to your demand.

Copper crimping terminals with Nylon

Copper crimping terminals with Nylon

Q: 1000 kW 600 m cable to use much
Three-phase 380V, 1000 kilowatts load, the working current is about: 1899A. The total area of copper cable is not less than: 1200 mm2 copper cable. . the cable is usually a few or several groups of wires (at least two each) twisted from the rope-like cable, each group of wires are insulated from each other, and often around a center twisted, the entire outer package Highly insulated cover. Cable with internal power, external insulation characteristics. . the cable has power cables, control cables, compensation cables, shielded cables, high temperature cables, computer cables, signal cables, coaxial cables, fire cables, marine cables, mining cables, aluminum cables and so on. They are composed of single or multi-strand wire and insulation layer, used to connect the circuit, electrical appliances and so on.
Q: Is the cable head made of every building?
First, the cable production and installation of each building has. Second, the cable terminal set of waterproof, stress control, shielding, insulation in one, with good electrical and mechanical properties, in a variety of harsh environmental conditions for long-term use. With the advantages of light weight, easy installation and so on. Cable terminal is widely used in electric power, petrochemical, metallurgy, railway ports and construction and other fields. Third, the production process: including the following: . cut off the excess cable; . the cable protective layer of the stripping; . conductor connection; . wrapped around insulation (or shrink pipe); . install the connector shell; . ; . for sealing treatment.
Q: What is the meaning of PG + digital markings for electrical wiring?
If no color distinction, 100 meters after you know which line of the fire line which line? The
Q: How much of the cable with the switch?
The switch is not selected according to the cable and is selected according to the current. The cable is determined by the size of the power (converted to current) and the distance from which the distance is far. The greater the power distance, the greater the cross-sectional area of the required cable. For example: 15KW motor selection cable current I = P / 1.732UcosΦ = 15 / 1.732 / 0.38 / 0.8 = 28A if it is close (within tens of meters), copper cable 6 square millimeters, aluminum cable 10 square millimeters. If it is in the distance (a few hundred meters), copper cable 10 square millimeters, aluminum cable 16 square millimeters. If it is long distance (close to kilometers), copper cable 16 square millimeters, aluminum cable 25 square millimeters. The switch is regardless of distance, completely based on the load current to choose, generally according to the load current of 1.5 times to 2 times to choose.
Q: Does anyone know the "line buckle" classification (including shape / size / material / has been some commonly used size!) Line deduction is a hardware products! For daily necessities!
In accordance with the relevant safety regulations, the power cable should not be parallel to the top of the thermal pipe laying, when can not be avoided, the interval distance should not be less than 1000mm, during which should also take effective insulation measures. Power cable and thermal pipe cross, the thermal pipe insulation layer, the separation distance should be not less than 500mm, no insulation layer should not be less than 1000mm, and in the cross with the insulation board to be protected, the length of the insulation board should not be less than d + 2000mm (d for the thermal pipe insulation layer diameter).
Q: Can the main cable be aluminum cable? And explain why, thank you!
Reply to the landlord: I read a part of the literature, more Google is aware of the following part may be your reference weak construction specifications 1
Q: 5 air conditioning can be used 4 square cable
Lengthened low voltage side, the line resistance increases, the voltage drop increases. Reduced load capacity. So that the router due to insufficient supply voltage and can not work properly. It is not allowed to use 9V power supply. Voltage is too high, the router part of the internal power supply increased power, heat increased, it is possible to burn the router. It is necessary to extend the power cord, I suggest you extend the power supply side (220V one end) safe and reliable. Increase the voltage to increase the supply current, in the electrical working voltage range (with the electrical work voltage range) is allowed, too low electrical appliances can not work properly. Too high there is the risk of burning appliances, according to your actual situation, marked 5V0.2A that the router works at rated voltage, so the way to improve the supply voltage is not applicable. So you can only improve the power supply power (that is, you say to increase the power supply current rather than voltage). With the reserve power, it will provide enough current at the rated voltage (the router as a resistor, from I = U / R, you can know the danger of increasing the voltage) need help please message
Q: How do I ask for cable prices? How many tons is one or more?
Yellow line is video, red and white are audio, you can only pick one!
Q: 6 square cable up to how many air conditioning (1.5P)
1 square millimeters can flow 4A current, 1KW380V, then the current is about P = UI about 2.6A7KW, 380V, then the current is about 18A, each with the line to share 18/3 = 6A2.5 square mm of copper on it. Of the area need to take . probably 6 level. V is probably 7KW220VI = p / u = 7000/220 = 31A. Then need 10 square millimeters of copper.
Q: 25 square copper cable how much money one meter?
3000w electrical work at 220V voltage is about 13.6A (current = power divided by voltage). Copper core line of the working current is generally a square 4-6A. That is to say you use 3-4 square power cord more secure.
We have increased our production capability. Quality control standards are being raised and improved to meet the growing international demands. We have greatly expanded our market year by year and we now have satisfied customers all over the world.

1. Manufacturer Overview

Location Guangdong,China
Year Established
Annual Output Value
Main Markets North America, South America, Eastern Europe, Southeast Asia, Africa, Oceania, Mid East, Eastern Asia, Western Europe
Company Certifications ISO 9001:2008

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a) Trade Capacity
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b) Factory Information
Factory Size: 5,000-10,000 square meters
No. of Production Lines
Contract Manufacturing OEM Service Offered
Product Price Range

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

Hot products


Hot Searches