SET SCREW EMT CONNECTOR-ALUMINUM ,American Standard, NPT Thread
- Loading Port:
- Ningbo
- Payment Terms:
- TT or LC
- Min Order Qty:
- 1000 pc
- Supply Capability:
- 300000 pc/month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
Description:
EMT connectors are used in dry locations to bond EMT conduit to electrical junction boxes or enclosures. EMT connectors provide concrete tight connections when taped and properly secured with the included locknut, and are rated for electrical applications above 600 volts. Their heavy gauge steel construction maintains mechanical protection and solid grounding of the conduit to the designated electrical junction box or enclosure.
EMT Connector
American Standard, NPT Thread
UL Standard 514B
Size: Zinc 1/2" to 4"
Aluminum 1/2" to 2"
Material: Zinc/Aluminum Die Cast
Applications:
EMT connector: Joins steel EMT conduit to Electrical box
•Connect & effectively bond EMT conduit to steel outlet boxes, load centers & other metal enclosures
•May be used indoors and in concrete-tight applications when taped
•Body and locknut made with die-cast zinc alloy
•Tri-Drive screw head design for use with Phillips, slotted and square screwdrivers
•Screw thread is designed to not vibrate loose
•Reversible locknut designed to cut through protective coatings on boxes & enclosures
•UL standard for safety
•Application type : EMT
•Electrical Product Type : Standard Fitting
•Fitting type : Connector
•Indoor/Outdoor : Indoor
•Paintable/Stainable : No
•Returnable : 90-Day
•Trade Size (in.) : [1/2"] [3/4"] [1"] [1-1/4"] [1-1/2"] [2"]
Competitive Advantage:
+Quick Delivery: 30 days for one 20ft container.
+Competitive Price
+ Good Quality: ISO/UL certificate approval
+Best Service: fast delivery, strong package, good price, timely and effective communication
+Powerful Solution: fast and effective solution to problem
- Q:5 air conditioning can be used 4 square cable
- Such as the extension line added to the adapter primary (city side) certainly easy to use. Extended by two meters, the router does not start, may be extended wire diameter is too thin, bold wire try. If not, choose 6V2A adapter try, the voltage is too high will burn the router. Increase the current is no problem, just like the computer's power, 300-watt power can be replaced, and small is not OK.
- Q:How much of the cable with the switch?
- The switch is selected according to the current. General switch = (2-2.5) Current three-phase current = P / 1.732 / 0.38 / 0.8 Single-phase current = P / 0.22 / 0.8
- Q:What is the meaning of PG + digital markings for electrical wiring?
- Will the general power cable control cable can do the largest square...
- Q:25 square copper cable how much money one meter?
- Copper should be more than 2.7 flat. Aluminum to 4.5 or more.
- Q:Is the cable head made of every building?
- Building in accordance with the floor or unit configuration distribution box, there are office buildings using a total box. Where there is a cable out of the situation, must be wrapped to make the cable head, according to the choice of distribution box circuit breaker wiring crimp or not crimp the cable terminal. In other words, the cable head must be made, but not necessarily crimp the cable terminal.
- Q:6 square cable up to how many air conditioning (1.5P)
- 1 square millimeters can flow 4A current, 1KW380V, then the current is about P = UI about 2.6A7KW, 380V, then the current is about 18A, each with the line to share 18/3 = 6A2.5 square mm of copper on it. Of the area need to take . probably 6 level. V is probably 7KW220VI = p / u = 7000/220 = 31A. Then need 10 square millimeters of copper.
- Q:Does anyone know the "line buckle" classification (including shape / size / material / has been some commonly used size!) Line deduction is a hardware products! For daily necessities!
- In accordance with the relevant safety regulations, the power cable should not be parallel to the top of the thermal pipe laying, when can not be avoided, the interval distance should not be less than 1000mm, during which should also take effective insulation measures. Power cable and thermal pipe cross, the thermal pipe insulation layer, the separation distance should be not less than 500mm, no insulation layer should not be less than 1000mm, and in the cross with the insulation board to be protected, the length of the insulation board should not be less than d + 2000mm (d for the thermal pipe insulation layer diameter).
- Q:Can the main cable be aluminum cable? And explain why, thank you!
- Reply to the landlord: I read a part of the literature, more Google is aware of the following part may be your reference weak construction specifications 1
- Q:3 by 16 cable is a few flat? How? That 5 by 16?
- Is the power directly out of the CPU power supply line or on this basis and added the extension line
- Q:How do I ask for cable prices? How many tons is one or more?
- Cable bridge grounding should belong to the protective grounding, grounding resistance at a cross point is not greater than 50 milliohms, no jumper no more than 5 milliohms
1. Manufacturer Overview |
|
---|---|
Location | |
Year Established | |
Annual Output Value | |
Main Markets | |
Company Certifications |
2. Manufacturer Certificates |
|
---|---|
a) Certification Name | |
Range | |
Reference | |
Validity Period |
3. Manufacturer Capability |
|
---|---|
a)Trade Capacity | |
Nearest Port | |
Export Percentage | |
No.of Employees in Trade Department | |
Language Spoken: | |
b)Factory Information | |
Factory Size: | |
No. of Production Lines | |
Contract Manufacturing | |
Product Price Range |
Send your message to us
SET SCREW EMT CONNECTOR-ALUMINUM ,American Standard, NPT Thread
- Loading Port:
- Ningbo
- Payment Terms:
- TT or LC
- Min Order Qty:
- 1000 pc
- Supply Capability:
- 300000 pc/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches
Related keywords