• Semi-conductive Nylon Tape System 1
  • Semi-conductive Nylon Tape System 2
Semi-conductive Nylon Tape

Semi-conductive Nylon Tape

Ref Price:
get latest price
Loading Port:
Shanghai
Payment Terms:
TT or LC
Min Order Qty:
-
Supply Capability:
10000m2 m²/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

1. Product Description:

Semi-conductive nylon tape applies to the wrapping around the conductor of high voltage cross-linked polyethylene cable, oil cable and mine cable, for it has shielding and binding function. It is also non corrosive.

2. Product Characteristic:

At the same time, special solid color jacquard, heat transfer, softening treatment, can also according to customer requirements and processing all kinds of nylon webbing. High strength, is not easy to break, hygroscopicity poor, poor elasticity, dyeing performance in low temperature (60 DEG C) and can be painted, but poor light fastness, constant period according to color will and strength decreases, have to shrink, burning white smoke, odor of ammonia (dirty. It smells bad).

 

3.Specification

Property

Unit

Semi-conductive Nylon Tape

Thickness

mm

0.10±0.02

0.12±0.02

0.14±0.02

Unit weight

g/m2

90±10

100±10

110±10

Tensile strength

N/cm

≥100

≥120

≥140

Elongation at break

%

≥20

≥25

≥25

Surface resistivity

Ω

<1500

<1500

<1500

Volumn resistivity

Ω·cm

<1×106

<1×106

<1×106

Short term stability

230

230

230

Long term stability

145

145

145

 

4. Reference Picture:

 

 

 

Q:What brand of cable is good, what are the top ten brands of wires?
If you are talking about the three-core wire, black - ground brown - line of blue - zero line. If it is 3 plugs, your wire is only 2 lines. Then the yellow received L, black received N. The above is the ground wire.
Q:This cable or accessory has not been certified and may not be able to work with this iphone reliably
The operation of the hydraulic pipe is very simple to see it will engage in their own, embedded more simple, and then get the construction site in accordance with the requirements of the drawings put away, tied with tie wire on the OK Mouth up the pipe to use cement bag to prevent good, to prevent the infusion of concrete, so buried even if the end
Q:Wire and cable: RVFV. : RVFSV. : UTP-CAT5E. : SYV-F-75-5 : RVFSP. : RVSP. : RVFVSP. What is the type of wire? Solve! More
If you need an unqualified wire, you can contact this part
Q:Decoration when the purchase of water pipes, wires and other items included in the account
Outdoor fire line must use fire-resistant KVV cable, wear pipe protection.
Q:How to determine how much wire and cable should be used, the current load and how the corresponding wire, such as 4BV, under what circumstances, YJV240 what circumstances, the load is much more
The second floor of the formula is correct, my space also have this formula, with armor and no armor in the current no difference, there are differences in the installation, usually buried to armor, overhead or bridge without armor, you give the model is not Armor, YJV-4 * 240 without armor, YJV-22-4 * 240 armor,
Q:IPhone6 This cable or accessories have not been certified how to solve
Labor costs you can and workers to discuss, and some labor costs are calculated in accordance with square meters, and some are calculated in accordance with the day, the specific or ask the local construction team
Q:Wire and cable model ZD what does it mean
The middle of the line is not a problem where there is a problem in the place where the joints check the place of the joints can not do the lines are out to check the time and effort
Q:Apple phone display cable or accessories not certified how to do
Reply 3 # shops always have the door, and the door must be adjacent to the outdoor channel. Outdoor channel is public space! So the shop should be able to find the wiring channel. You have not encountered the situation, the map stickers out to see it?
Q:Rt, the charger did not change, has been no problem before, today just plugged into the charger, the results appear as if the problem, before the out of this problem, and now only ipad power off after the power can not be charged, and ipad start , Then immediately prompted the title, can not charge more
The proportion of the cross-sectional area of the cable through the embedded pipe is 20%
Q:Ipad not charge how the matter. Said the cable or accessories have not been certified, and may not be able to cooperate with this ipad reliable work....
According to the "Power Engineering Cable Design Code" GB-. 5.3.3 only asked for the depth of the cable buried directly: drop the blue skin to the ground depth, not less than 0.7 meters; when located in the roadway or farmland Under the appropriate should be deepened, and should not be less than 1.0 meters. 5.4.3 protected pipe buried in the ground, should meet the requirements under the depth of the pressure and environmental corrosion resistance. Through the uneven settlement of the backfill section and other places to increase the force, it is appropriate to use steel. Another direct burial should be selected armor type.

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

Hot products


Hot Searches

Related keywords