Description: Stainless Steel Wire Overbraided Plastic Flexible Hose, Flexible Conduit, Flexible tubing, Corrugated tubing, Corrugated hose, Plastic Conduit. 

Item No.: NK206 Series 
Material: Inside Polyamide 6, outside steel wire 
Temperature range: -40C~+120C, short term to +150C 
Color: Silver Grey 
Flame-retardant: Vo (UL94) 
Protection degree: IP68 
Properties: Anti-explosion, Flexible and excellent tenacity, glossy surface, high mechanical strength, wind resistant, anti-friction, resistant to oil, acid and solvents, uv-resistant, insulated, free of halogen, phosphor and cadmium. 
Applications: Manchine tool, machine building, electric insulation protection system, electric automatic control system, public traffic equipment, metro, electric locomotive and air-condition equipment, etc. 
Certificate: CE, SGS, RoHS 

Size: 1/4", 5/16", 3/8", 1/2", 3/4", 1", 1-1/4", 2" 
I. D.: 6.5-46.5mm 
O. D.: 10.0-55.2mm 

COMPANY PROFILE 
Guangzhou Jieyin Electric Appliances Co., Ltd. (abbreviation Jieyin APA ) was established on March in 1999. It is a producer professionally engaged in wire protect-tube and cabling accessories. Jieyin established APA brand of several types of soft tube series. Years of accumulated experience made Jieyin APA to be an outstanding enterprise in field of wire and cable protection system. 

Jieyin APA persist high quality of products. In the production process, we adhere to the standard of ISO9001 qualification system and domestic standard. According to ISO9001 qualification management system, our high-quality products won certifications of CE, ROSH, etc. 

Main productions: 
- Polyamide Tubing, Polyethylene Tubing, Polypropylene Tubing, Wiring Duct 
- Increased-Safety Overbraided Liquid-Tight Flexible Conduits, Increased-Safety Overbraided Flexible Conduits 
- Heavy Duty Connectors 
- Flex Cable 
- Cable Chain 
- Cable Gland(Nylon), Cable Gland(Metal) 
- Hibox

Item No.
 
Size
 
I.D.(mm)
 
O.D.(mm)
 
Stat.r(mm
 
Dyn.r(mm)
 
Packing
Meter/Roll
 
NK206
 
 1/4"
 
 6.7
 
 11.3
 
 15
 
 30
 
 200
 
NK206
 
 5/16"
 
 10.1
 
 14.3
 
 20
 
 40
 
 100
 
NK206
 
 3/8"
 
 12.2
 
 17.1
 
 30
 
 50
 
 100
 
NK206
 
 1/2"
 
 16.7
 
 22.3
 
 40
 
 70
 
 100
 
NK206
 
 3/4"
 
 22.6
 
 30.1
 
 50
 
 100
 
 100
 
NK206
 
 1"
 
 28.3
 
 35.8
 
 60
 
 120
 
 50
 
NK206
 
1-1/4"
 
 36.1
 
 44.2
 
 80
 
 150
 
 25
 
NK206
 
 2"
 
 47.4
 
 56.8
 
 100
 
 180
 
 25
 
NK206
 
 12
 
 8.4
 
 13
 
 35
 
 60
 
 100
 
NK206
 
 12.5
 
9.4
 
13.8
 
 35
 
 60
 
 100
 
NK206
 
 18.5
 
 14.4
 
 19.5
 
 35
 
 60
 
 100
 
NK206
 
 25
 
 20.1
 
26.5
 
 45
 
 80
 
 100
 
NK206
 
 32
 
 26.5
 
 32.6
 
 55
 
 100
 
 50


Q:Will the embedded stove why use stainless steel corrugated hose connection?
62-2 meets the requirements 3 The deformation rate of the flexible pipe shall not exceed the design requirements or the provisions of regulation 45 the longitudinal wall shall not appear in the pipe wall, and the annular and other deformation shall be in accordance with regulation 462-3 The requirements of the 4 backfill compaction should meet the design requirements, design requirements, should meet the requirements of Table 463- Table 463-2 Flexible pipe groove backfill site and compaction see Figure 463 Article 462-4 meet the requirements of the general items 1 backfill should reach the design elevation, the surface should be flattened Section 462-5 meet the requirements 2 backfill pipe and ancillary structures without damage, settlement, displacement Section 462-6 Conformity to allowable deviation Average pass rate (%)
Q:Safety evaluation: gas pipeline and discharge pipe should not be set between the valve, what is the specification of which provisions?
In the past, the external wall insulation technology prevails, the external wall insulation is in the experimental stage, Basically no
Q:What is the effect of concrete pouring on the construction quality?
The use of the trench connection to check the pipe sealing surface is smooth, smooth, no burr. Whether the sealing surface of the sealing ring is scratched, whether the length of the sealing section of the pipe meets the requirements. These three points to ensure that certainly not leaking.
Q:How is the flexible tube of FRP composite pipe defined
I am not an expert and have occasionally slept on the foam board. Personal feeling sleep in the above airtight, but also hot, easy to get angry.
Q:Where there are wear-resistant tube, high temperature ceramic tube
The fraction of 200 ℃ in the condensed product was analyzed by GC-MS, and the degradation phenomena and products were discussed
Q:What materials are made of flexible pipes? Why should the mechanical ventilation set the flexible tube? Where should I be located?
Masonry structure construction, the number of pole set which several
Q:Is the clamp type flexible connector connected to the pipe to the rubber pad?
See the situation, the general 3 percent or so, to see how the management of LZ, hand thank you
Q:Is the flexible sleeve of the broken wall used as a second retest?
The national standard is 18kg. Color steel sandwich panel is a common product in the current building materials, do not chu chu dumpling seal festival over the extinguished Long can only be a good flame retardant and environmentally friendly and efficient. Caigang sandwich board has two layers of metal panels and the middle of the polymer core insulation from the suppression. With the installation is simple, light and efficient light and efficient features. And the filling system used to close the molecular structure of the closed, you can put an end to the condensation of water vapor.
Q:Can the kitchen sewage pipe pass through the walls of the stove wall?
scaffolding pole base with the height must be high longitudinal bar to the lower extension of the two spans and pole fixed height difference should be 1m by slope slope of the vertical axis of the slope should be 500mm single, double Row scaffolding bottom step should be 2m single row, double row and full of scaffolding stand in addition to the top of the top step outside the other layers of each step must be connected with the fastener scaffolding pole connection, lap should be consistent with the column Provisions: the use of connecting rods should be staggered with two adjacent rods should be arranged to set the synchronization within the synchronization within the separation of the two-phase separation of the distance from the distance to 500 mm; each connected to the main node the use of lap joint lap joint should be at 1m and should be used less than 2 rotating fasteners fixed end fastener cover edge to the rod end distance should be 100mm scaffolding Pole top rail bar should be high wall end 1m should eaves mouth 15m
Q:How to optimize the construction management to improve the quality of construction projects
I suggest you look at Google, there will be a lot, I hope you can find a satisfactory, I wish you a happy life!

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

New products

Hot products


Hot Searches