Polyethylene Geomembrane Fish Farm Pond Liner with Black/White for Pond
- Loading Port:
- Qingdao
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 10000 m²
- Supply Capability:
- 500000 m²/month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
Structure of Fish Farm Pond Liner
Fish Farm Pond Liner are made from polyethylene polymer materials that blow molding,its main function is to prevent the liquid leakage and gas volatile.According to the production of raw materials can divide into HDPE geomembrane liner and EVA geomembrane liner,etc.
Main Features of Fish Farm Pond Liner:
Complete variety of specifications of width and thickness. Thickness: 0.08-2mm/Width: 2-16m .
Excellent environmental stress resistant cracking performance.
Excellent performance of chemical erosion resistance.
Big scope of application temperature and long service life .
Applied in landfill waste site, sewage and filth treatment site, tailings depot and underground construction project
Fish Farm Pond Liner Images
Fish Farm Pond Liner Specification :
No. | Item | Test Value | |||||||
0.75mm | 1.0 mm | 1.25 mm | 1.5 mm | 1.8mm | 2.0mm | 2.5 mm | 3.0mm | ||
1 | Minimum Density(g/cm³) | 0.94 | |||||||
2 | Strength at yield,N/mm | 11 | 15 | 18 | 23 | 27 | 30 | 38 | 45 |
3 | Strength at break ,N/mm | 21 | 28 | 33 | 43 | 51 | 57 | 71 | 85 |
4 | Elongation at yield,% | 13 | |||||||
5 | Elongation at break,% | 700min | |||||||
6 | Tear Resistance N | 93 | 125 | 156 | 187 | 219 | 249 | 311 | 373 |
7 | Puncture Resistance N | 263 | 352 | 440 | 530 | 618 | 703 | 881 | 1059 |
8 | Stress Crack Resistance, hrs | 400 | |||||||
9 | Carbon Black Content, % | 2.0-3.0 | |||||||
Carbon Black Dispersion | 1 or 2 | ||||||||
10 | Standard OTI Min | 100 | |||||||
High Pressure OTI Min | 400 | ||||||||
11 | Impact Cold Crack at -70°C | Pass | |||||||
12 | Water vapor permeability (g.cm/cm2 .s.Pa) | ≤1.0×10-13 | |||||||
13 | Dimensional Stability (%) | ±2 |
FAQ:
1. How about the delivery time?
Two weeks upon receipt of down payment.
2. What kind of payments do we accepted?
T/T, L/C, WesternUnion, MoneyGram.
3. What's are the MOQ?
Normally the MOQ is 5000 SQM in theory.
And we can provide you free samples for quality inspection.
4. Do you charge for the samples?
Accordeing to our company policy, the samples are freee, we only charge the freight fee. And we will return the freight fee in your second order.
5. Can you produce the product according to customers' requirements?
Sure, we are professional manufacturer, OEM and ODM are both welcome
- Q: Does the blue-ray of mobile phone screen protector have any effect?
- Blue light mobile phone film is a kind of eyesight protective?film based on the research and development of blue-ray radiation. Blue mobile phone film use blue block technology to absorpt and transform the blue-ray, which can realize the effective blocking of blue-ray and achieve the goal of protecting eyesight. What is blue light, it is well known that ultraviolet light has a great damage to the eyes, the consumer should know use ultraviolet-proof sunglasses to protect their eyes. So whether the light is harmful to the eyes? Recent researches find that short-wave visible light is purple light and blue light which has great destructive effect to the fundus retina, it is also called "blue light damage phenomenon" in the western ophthalmology. Damaging effects of blue light is a chain reaction, it first cause light-sensitive cell death, and then cause macular degeneration, and then lead to decreased vision or even completely lost. Western population survey: 20% of people has age-related macular degeneration in the age of 65, it has become almost epidemic ophthalmology. Now, the growing popularity of computers, televisions, game consoles and other screen products give us enjoyment and efficience in our work and life, but at the same time, it also deeply hurt the eyes, artificial light "light pollution" it produced has become the leading cause of juvenile myopia. Wear protective glasses can play a good preventive effect when you face the screen.
- Q: Which is better between electric?hot?plate and electrothermal?film?
- It depends on actual situation, which can not be directly determined which one is good. The electrothermal?film is a kind of exothermic material made of special conductive macromolecule material matched with metal current-carrying strip, hot melted between the insulating film bodies, which will produce heat after being electrified Mainly used for heating element. The electric hot plate is equippment taking electric heating alloy wire as heating material, and mica soft board as insulating material, and wrapping thin metal plate (aluminum plate, stainless steel plate, etc) in the surface for heating. Typical applications like electric hot water bottles. Casting metal tubular electric heating element in aluminum plate/aluminum plate or welding or inlaying on the aluminum plate/aluminum plate to form electrical heating plate of all shapes. Typical application like electric cookers, electric irons, electric coffee makers, etc.. ! ~
- Q: Can geomembranes be used in reservoirs and dams?
- Yes, geomembranes can be used in reservoirs and dams. They are commonly employed as lining systems to prevent seepage and leakage of water from the structure. Geomembranes offer excellent impermeability, durability, and resistance to chemicals, making them an ideal solution for maintaining water containment in reservoirs and dams.
- Q: Can geomembranes be installed vertically?
- Yes, geomembranes can be installed vertically.
- Q: What is the difference between geomembrane and impermeable membrane?
- Impermeable membrane is impermeable geomembrane, including geomembrane, composite geomembrane, two cloth a film, a cloth a film. Geomembrane is HDPE geomembrane, geomembrane is a kind of polymer as the basic raw material waterproof barrier material. Mainly divided into: polyethylene (PE) geomembrane, PVC (PVC) geomembrane, chlorinated polyethylene (CPE) geomembrane and a variety of composite geomembrane and so on. Function: seepage, isolation purposes: geotechnical dam, rockfill dam, masonry dam and pressure concrete dam; dike, dam front level anti-seepage cover, vertical foundation impervious layer; tailings dam, sewage dam dam and reservoir Construction of cofferdam; channel, reservoir (pit, Khouang); waste yard; subway, basement and tunnel, tunnel seepage lining; highway, highway, railway roadbed; roadbed and other salt control; Collapsible loess waterproof layer; roof leakage products: two cloth a film (impermeable membrane on both sides with protective geotextile) a cloth a film (impermeable membrane side with protective geotextile) Width: 4-6 meters
- Q: Can geomembranes be used in rooftop gardens and green roofs?
- Yes, geomembranes can be used in rooftop gardens and green roofs. They are commonly used as a waterproofing layer to prevent water leakage and protect the underlying structures. Geomembranes also help retain moisture, control drainage, and protect plants from root penetration.
- Q: How does the effect of the electrothermal?film for heating?
- In the ealier stage, the heating effect of the electric heating film can is very good, but the electric heating film is with the power attenuation. Generally, the electric membrane manufacturers will say that the film is part of the bad, but also can continue to use. After a part of the electric heating film is broken, the power of the whole room is lower than that of the design power. Electric heating is intermittent work, and once the temperature is reached, it will stop working. The power attenuate, so it cannot up to the set temperature. The power consumption is relatively large, and the effect is not very ideal.
- Q: Water conservancy geotechnical membrane pe50 - 200 - 3 is what mean
- Thickness and weight
- Q: What are the technical requirements of permeable geotextile of two fabrics and one membrane?
- The indicators of porous composite membrane of two fabrics membrane: breaking strength 5kn, bursting 1.1kn, tearing 0.15kn, stripping 6n/cm or stripping is not found in breaking of base material. 2008 standard gram weight has required that the original standard should be lower than 360g.
- Q: What are the requirements of using the new geosynthetics?
- 1. In terms of reinforcement, the geogrid should be considered first. 2. The geosynthetics should not be laid directly on the surface of the original foundation. 3. When laying the geotextile material, it should be perpendicular to the axis of the road.
Send your message to us
Polyethylene Geomembrane Fish Farm Pond Liner with Black/White for Pond
- Loading Port:
- Qingdao
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 10000 m²
- Supply Capability:
- 500000 m²/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches
Related keywords