Production and research and essential non-contact 3D optical profiler
Some other three-dimensional topography contours are more difficult to measure accurately measured from the rough interface to smooth interface, hard to soft, sticky or. A very wide range of applications, such as in the field of scientific research, product development, process control, failure analysis, etc.
ContourGTTM set leading 64-bit, multi-functional operating and analysis software, patented technologies and white light interferometry easy maneuverability in an unprecedented, is the most advanced three-dimensional optical profiler. The tenth generation of optical profiler can quickly measure the vertical direction from the industrial areas of angstroms to millimeter field of view of the leading high-resolution images. ContourGT is currently the most powerful, the most extensive range of applications of the three-dimensional profile measurement system.
ContourGT-K0
ContourGT-K1
ContourGT-X3andX8
Property
Desktop; required shockproof
Desktop; required shockproof
Comes with shock sets; optional Ergotron arm
X-Y sample stage
150mm manual;
± 6 ° tilt modulation system
150mm manual;
Optional 150mm automatic;
± 6 ° tilt modulation system
200mm with encoder programmable;
300mm with encoder Programmable (optional);
The integrated scan head ± 6 ° tilt modulation system
Z
100mm Z axis manual
Computer control; optional joystick controller
Computer control; optional joystick controller
Integrated Optical Components
The latest generation of high-brightness dual-LED light source; FOV rotating tower
The latest generation of high-brightness dual-LED light source; FOV automatic rotating tower; Automated filter flipper
The latest generation of high-brightness dual-LED light source; FOV automatic rotating tower; Automated filter flipper
Objective lens
Parfocal: 2.5 ×, 5 ×, 10 ×, 20 ×, 50 ×
Long Working Distance: 2 ×, 5 ×, 10 ×
Parfocal: 2.5 ×, 5 ×, 10 ×, 20 ×, 50 ×;
Long Working Distance: 1 ×, 1.5 ×, 2 ×, 5 ×, 10 ×; objective turntable
Parfocal: 2.5 ×, 5 ×, 10 ×, 20 ×, 50 ×;
Long Working Distance: 1 ×, 1.5 ×, 2 ×, 5 ×, 10 ×; objective turntable
Lens turret
Single-lens adapter or manual turntable
Automatic turntable single lens adapter or four positions
Automatic turntable single lens adapter or four positions
Processor
Multicore, Windows 7.0
Multicore, Windows 7.0
Multicore, Windows 7.0
System Software
Vision64 operating analysis package
Vision64 operating analysis package
Vision64 operating analysis package
Optional analysis software
No
MATLAB®, SureVision, TCP / IPControl, ThickFilm, Annular, Optical
MATLAB®, SureVision, TCP / IPControl, ThickFilm, Annular, Optical
Other automatic operation
Automatic light intensity adjustment:
Autofocus camera
Automatic light intensity adjustment;
The camera auto-focus;
Optional told Focus;
Optional suture;
Optional X-Y automatic adjustment
Automatic light intensity adjustment;
The camera auto-focus;
Optional told Focus;
Optional suture;
Optional X-Y automatic adjustment
Calibration
Manually, using standard parts
Manually, using standard parts
X3: manually, using standard parts
X8: internal real-time self-calibration
Z measuring range
0.1nm to 10mm
0.1nm to 10mm
0.1nm to 10mm
Maximum scanning speed
28.1μm / sec
28.1μm / sec
X3:
X8: 92.5μm / sec
Maximum weight
4.5kg (10lbs)
4.5kg (10lbs)
45kg (100lbs
Warranty
12 months
Hungry unparalleled measurement performance, the industry's largest field of view of the highest vertical resolution
0.5 × magnification to 200 ×, to achieve a variety of different surface shapes and materials Measurement
In any magnification level to millimeter level have sub-angstrom vertical measurement range, to achieve unprecedented measurement flexibility
The optional high-resolution cameras to enhance the lateral resolution, to further improve the measurement repeatability and reproducibility
Excellent measurement hardware in industrial environments enhance the reliability and repeatability of measurements
Patented high-brightness dual-LED illumination provides superior measurement quality and magnification flexibility
Optimized hardware designed to enhance the ability of the instrument shock and measurement repeatability and reproducibility
Specific models of patented self-calibration technology to ensure consistency and accuracy and repeatability of the measurement machine and the machine between
Highly intuitive user interface, the highest degree of automation, the strongest analysis
Simple user interface simplifies operation and data acquisition, improve work efficiency of the system and the operator
Unique visualization tool bar provides a more intuitive filtering and analysis capabilities library
Users can customize the special needs of analytical data reporting
Whether your application requires manual measurement system or a dedicated 24x7, standard automatic measurements, ContourGT series have your specific application needs solutions
- Q: The urine analyzer belongs to several kinds of medical instruments
- Species are now testing glucose meter range, performance is also different, in order to ensure the blood glucose meter, reliable performance, accurate measuring results, the best to the nearest regular medical equipment company to inquire, compare the determination principle all blood glucose meter: blood glucose meter from the working principle of two respectively, a photoelectric type, one is electrode type. A blood glucose meter similar CD player, a photoelectric head, the utility model has the advantages of cheap, disadvantage is the detection head exposed to the air, it is easy to be contaminated, affect the test results, the error range of plus or minus 0.8, short service life, generally within two years is more accurate, is recommended after two years the use of photoelectric type machine to customer service service station with a head calibration and maintenance. Johnson's steady, steady pace, Roche's "Le Kang", "Luo Kang" congruence belong to this type.
- Q: What is the principle of automatic biochemical analyzer?
- The automatic biochemical analyzer belongs to an optical analytical instrument. It is based on the selective absorption of matter to light, that is, spectrophotometry. The monochromator of polychromatic light emitted by light source into monochromatic light, monochromatic light of specific wavelength containing sample solution than the color of the pool, the photoelectric sensor converts the transmitted light into electrical signal into the signal processing system is analyzed.
- Q: Laboratory equipment during the test
- During the verification methods can be divided into 5 categories: (1) to participate in interlaboratory comparison; (2) the use of certified reference material; (3) with the same accuracy grade of another device or several devices in the value comparison; (4) to be measured the stable value of re determination (i.e. use verification the standard during verification); (5) in resources permitting, self calibration can be of high grade.
- Q: The working principle of flue gas analyzer, with the brand
- This is the principle of electrochemical analyzer, i.e. smoke flue gas, flue gas into the gas analysis box, along the road, followed by each sensor, and the sensor produces chemical reaction, generate electrical signals, the manipulator on display.
- Q: What is the measuring line on the highway? Is it measured by an instrument such as a theodolite?
- The highway survey and lofting is to calibrate the design coordinates and design elevation of the middle line, the left and right side lines, the road revetment, the retaining wall, the side ditch and so on on the road design and construction drawings, and demarcate them to the actual position of the ground.The instrument can use a lot of road layout, a theodolite and leveling instrument, range finder or steel tape, total station, GPS-RTK, construction units of ordinary common Theodolite Level and measurement ruler, advanced equipment and specialized surveying and mapping units used in the total station and GPS etc..
- Q: What's the difference between a logical analyzer and a virtual oscilloscope?
- One is the tool of the logical domain, the other is the tool of time domain, not the advantage, but the two entirely different things!Logic analyzer channel is much, can see the logic signal of 1000 lines at the same time, oscillograph is 4 channel commonly.Logic analyzer can only distinguish two states 0 and 1, oscilloscope is generally 8 bit AD, 1/256 resolution can be used to analyze the signal.The logic analyzer is concerned with timing resolution and timing depth, and the oscilloscope is concerned with sampling rates, bandwidths, and storage lengths.Logic analyzer can be 16 layers of nested trigger (software debugging necessary), the oscilloscope can only have a trigger (or two layer trigger).Logic analyzer studies logic relation, establishment time and so on. Oscillograph studies jitter, overshoot, distortion, burr and noise.
- Q: About black head instrument
- Black head suction machine is not recommended, first of all, its price is not cheap, two, it can only suck the surface of the black head, and the following but not sucked away.
- Q: Could you tell me the error range of carbon and sulfur analysis?
- High frequency infrared carbon sulfur analyzer can analyze the metallic elements inside the C and S content, detailed parameters see below, while P, Si, Mn, Cr, Ni of these elements need to use multi elemental analyzer to measure range, these are not HCS-500 can measure the inside, such as single C and S measurement it is of course the measurement error range of high-frequency infrared carbon sulfur analyzer HCS-500 to be smaller, in a word, is a general instrument and equipment dedicated to the difference
- Q: What is the principle that the signal bandwidth of the instrument is much higher than the sampling rate?
- The sampling frequency limits the bandwidth requirement of the input signal.
- Q: What is the difference between leakage current and leakage current? What instruments are used separately?
- Leakage current test requires a dedicated instrument (not a micro meter test, otherwise, once the breakdown current occurs, it will burn a micro meter, a major accident). The "leakage current" depends on the line to be measured (or circuit, such as circuit version), and choose the appropriate instrument (or ammeter) to carry out.