• Optical Profiler System System 1
Optical Profiler System

Optical Profiler System

Ref Price:
get latest price
Loading Port:
China Main Port
Payment Terms:
TT OR LC
Min Order Qty:
-
Supply Capability:
-

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

Production and research and essential non-contact 3D optical profiler


Some other three-dimensional topography contours are more difficult to measure accurately measured from the rough interface to smooth interface, hard to soft, sticky or. A very wide range of applications, such as in the field of scientific research, product development, process control, failure analysis, etc.


ContourGTTM set leading 64-bit, multi-functional operating and analysis software, patented technologies and white light interferometry easy maneuverability in an unprecedented, is the most advanced three-dimensional optical profiler. The tenth generation of optical profiler can quickly measure the vertical direction from the industrial areas of angstroms to millimeter field of view of the leading high-resolution images. ContourGT is currently the most powerful, the most extensive range of applications of the three-dimensional profile measurement system.


ContourGT-K0

ContourGT-K1

ContourGT-X3andX8


Property

Desktop; required shockproof

Desktop; required shockproof

Comes with shock sets; optional Ergotron arm


X-Y sample stage

150mm manual;

± 6 ° tilt modulation system

150mm manual;

Optional 150mm automatic;

± 6 ° tilt modulation system

200mm with encoder programmable;

300mm with encoder Programmable (optional);

The integrated scan head ± 6 ° tilt modulation system


Z

100mm Z axis manual

Computer control; optional joystick controller

Computer control; optional joystick controller


Integrated Optical Components

The latest generation of high-brightness dual-LED light source; FOV rotating tower

The latest generation of high-brightness dual-LED light source; FOV automatic rotating tower; Automated filter flipper

The latest generation of high-brightness dual-LED light source; FOV automatic rotating tower; Automated filter flipper


Objective lens

Parfocal: 2.5 ×, 5 ×, 10 ×, 20 ×, 50 ×

Long Working Distance: 2 ×, 5 ×, 10 ×

Parfocal: 2.5 ×, 5 ×, 10 ×, 20 ×, 50 ×;

Long Working Distance: 1 ×, 1.5 ×, 2 ×, 5 ×, 10 ×; objective turntable

Parfocal: 2.5 ×, 5 ×, 10 ×, 20 ×, 50 ×;

Long Working Distance: 1 ×, 1.5 ×, 2 ×, 5 ×, 10 ×; objective turntable


Lens turret

Single-lens adapter or manual turntable

Automatic turntable single lens adapter or four positions

Automatic turntable single lens adapter or four positions


Processor

Multicore, Windows 7.0

Multicore, Windows 7.0

Multicore, Windows 7.0


System Software

Vision64 operating analysis package

Vision64 operating analysis package

Vision64 operating analysis package


Optional analysis software

No

MATLAB®, SureVision, TCP / IPControl, ThickFilm, Annular, Optical

MATLAB®, SureVision, TCP / IPControl, ThickFilm, Annular, Optical


Other automatic operation

Automatic light intensity adjustment:

Autofocus camera

Automatic light intensity adjustment;

The camera auto-focus;

Optional told Focus;

Optional suture;

Optional X-Y automatic adjustment

Automatic light intensity adjustment;

The camera auto-focus;

Optional told Focus;

Optional suture;

Optional X-Y automatic adjustment


Calibration

Manually, using standard parts

Manually, using standard parts

X3: manually, using standard parts

X8: internal real-time self-calibration


Z measuring range

0.1nm to 10mm

0.1nm to 10mm

0.1nm to 10mm


Maximum scanning speed

28.1μm / sec

28.1μm / sec

X3:

X8: 92.5μm / sec


Maximum weight

4.5kg (10lbs)

4.5kg (10lbs)

45kg (100lbs


Warranty

12 months


Hungry unparalleled measurement performance, the industry's largest field of view of the highest vertical resolution

0.5 × magnification to 200 ×, to achieve a variety of different surface shapes and materials Measurement

In any magnification level to millimeter level have sub-angstrom vertical measurement range, to achieve unprecedented measurement flexibility

The optional high-resolution cameras to enhance the lateral resolution, to further improve the measurement repeatability and reproducibility


Excellent measurement hardware in industrial environments enhance the reliability and repeatability of measurements

Patented high-brightness dual-LED illumination provides superior measurement quality and magnification flexibility

Optimized hardware designed to enhance the ability of the instrument shock and measurement repeatability and reproducibility

Specific models of patented self-calibration technology to ensure consistency and accuracy and repeatability of the measurement machine and the machine between


Highly intuitive user interface, the highest degree of automation, the strongest analysis

Simple user interface simplifies operation and data acquisition, improve work efficiency of the system and the operator

Unique visualization tool bar provides a more intuitive filtering and analysis capabilities library

Users can customize the special needs of analytical data reporting


Whether your application requires manual measurement system or a dedicated 24x7, standard automatic measurements, ContourGT series have your specific application needs solutions


Q: The urine analyzer belongs to several kinds of medical instruments
Species are now testing glucose meter range, performance is also different, in order to ensure the blood glucose meter, reliable performance, accurate measuring results, the best to the nearest regular medical equipment company to inquire, compare the determination principle all blood glucose meter: blood glucose meter from the working principle of two respectively, a photoelectric type, one is electrode type. A blood glucose meter similar CD player, a photoelectric head, the utility model has the advantages of cheap, disadvantage is the detection head exposed to the air, it is easy to be contaminated, affect the test results, the error range of plus or minus 0.8, short service life, generally within two years is more accurate, is recommended after two years the use of photoelectric type machine to customer service service station with a head calibration and maintenance. Johnson's steady, steady pace, Roche's "Le Kang", "Luo Kang" congruence belong to this type.
Q: What is the principle of automatic biochemical analyzer?
The automatic biochemical analyzer belongs to an optical analytical instrument. It is based on the selective absorption of matter to light, that is, spectrophotometry. The monochromator of polychromatic light emitted by light source into monochromatic light, monochromatic light of specific wavelength containing sample solution than the color of the pool, the photoelectric sensor converts the transmitted light into electrical signal into the signal processing system is analyzed.
Q: Laboratory equipment during the test
During the verification methods can be divided into 5 categories: (1) to participate in interlaboratory comparison; (2) the use of certified reference material; (3) with the same accuracy grade of another device or several devices in the value comparison; (4) to be measured the stable value of re determination (i.e. use verification the standard during verification); (5) in resources permitting, self calibration can be of high grade.
Q: The working principle of flue gas analyzer, with the brand
This is the principle of electrochemical analyzer, i.e. smoke flue gas, flue gas into the gas analysis box, along the road, followed by each sensor, and the sensor produces chemical reaction, generate electrical signals, the manipulator on display.
Q: What is the measuring line on the highway? Is it measured by an instrument such as a theodolite?
The highway survey and lofting is to calibrate the design coordinates and design elevation of the middle line, the left and right side lines, the road revetment, the retaining wall, the side ditch and so on on the road design and construction drawings, and demarcate them to the actual position of the ground.The instrument can use a lot of road layout, a theodolite and leveling instrument, range finder or steel tape, total station, GPS-RTK, construction units of ordinary common Theodolite Level and measurement ruler, advanced equipment and specialized surveying and mapping units used in the total station and GPS etc..
Q: What's the difference between a logical analyzer and a virtual oscilloscope?
One is the tool of the logical domain, the other is the tool of time domain, not the advantage, but the two entirely different things!Logic analyzer channel is much, can see the logic signal of 1000 lines at the same time, oscillograph is 4 channel commonly.Logic analyzer can only distinguish two states 0 and 1, oscilloscope is generally 8 bit AD, 1/256 resolution can be used to analyze the signal.The logic analyzer is concerned with timing resolution and timing depth, and the oscilloscope is concerned with sampling rates, bandwidths, and storage lengths.Logic analyzer can be 16 layers of nested trigger (software debugging necessary), the oscilloscope can only have a trigger (or two layer trigger).Logic analyzer studies logic relation, establishment time and so on. Oscillograph studies jitter, overshoot, distortion, burr and noise.
Q: About black head instrument
Black head suction machine is not recommended, first of all, its price is not cheap, two, it can only suck the surface of the black head, and the following but not sucked away.
Q: Could you tell me the error range of carbon and sulfur analysis?
High frequency infrared carbon sulfur analyzer can analyze the metallic elements inside the C and S content, detailed parameters see below, while P, Si, Mn, Cr, Ni of these elements need to use multi elemental analyzer to measure range, these are not HCS-500 can measure the inside, such as single C and S measurement it is of course the measurement error range of high-frequency infrared carbon sulfur analyzer HCS-500 to be smaller, in a word, is a general instrument and equipment dedicated to the difference
Q: What is the principle that the signal bandwidth of the instrument is much higher than the sampling rate?
The sampling frequency limits the bandwidth requirement of the input signal.
Q: What is the difference between leakage current and leakage current? What instruments are used separately?
Leakage current test requires a dedicated instrument (not a micro meter test, otherwise, once the breakdown current occurs, it will burn a micro meter, a major accident). The "leakage current" depends on the line to be measured (or circuit, such as circuit version), and choose the appropriate instrument (or ammeter) to carry out.

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

Hot products


Hot Searches

Related keywords