Non Exposure Homogenous PVC Membrane for Roofing with Backing 2.0mm
- Loading Port:
- China Main Port
- Payment Terms:
- TT or LC
- Min Order Qty:
- 1000 Square Meters m²
- Supply Capability:
- 200000 Square Meters per Week m²/month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
Non Exposure Homogenous PVC Membrane
Service life of 20 years for exposed use;
High puncture and rooting resistance, especially suitable for planting roof system;
enhances the breaking and tear strength.
Features of Non Exposure Homogenous PVC Membrane
- Excellent performance in aging resistance, service life of 20 years for exposed use, and 50 years for non-exposed application
- High puncture and rooting resistance, especially suitable for planting roof system
- Easy installation and hot-air welding seam, environment friendly
- High tensile strength and elongation, size stability
- Good plasticity, convenient for detailing and coners installation
- Inherently fire resistant
- Smooth surface, unfading and stain resistance
No. |
Item |
Specification | ||
Type II |
Type III |
Type IV | ||
1 |
Overall thickness of PVC sheet, min, mm (in.) |
1.14 (0.045) |
1.14 (0.045) |
0.91 (0.036) |
2 |
Thickness over scrim, min. mm (in.)A |
0.40 (0.016) |
0.40 (0.016) |
0.40 (0.016) |
3
|
Tensile strength at break, min, MPa (psi): | |||
Machine direction |
10.3 (1500) |
... |
... | |
Cross-machine direction |
10.4 (1500) |
... |
... | |
4 |
Breaking strength, min, kN/m (lbf/in.) |
... |
35 (200) |
48 (275) |
5
|
Elongation at break, min, % | |||
Machine direction |
250 |
15B |
25B | |
Cross-machine direction |
220 |
15B |
25B | |
6 |
Seam strength, min, % of tensile or breaking strength |
75 |
75 |
75 |
7
|
Retention of properties after heat aging | |||
Tensile strength, min, % of original |
90 |
... |
... | |
Breaking strength, min, % of original |
... |
90 |
90 | |
Elongation, min, % of original |
90 |
90 |
90 | |
8 |
Tear resistance, min, N (lbf) |
45.0 (10.0) |
... |
... |
9 |
Tearing strength, min, N (lbf) |
... |
200 (45.0) |
400 (90.0) |
10 |
Low temperature bend |
pass |
pass |
pass |
11 |
Accelerated weathering test | |||
Cracking (73 magnification) |
none |
none |
none | |
Crazing (73 magnification) |
none |
none |
none | |
12 |
Linear dimensional change, max, % |
0.1 |
0.5 |
0.5 |
13 |
Change in weight after immersion in water, max, % |
±3.0 |
±3.0 |
±3.0 |
14 |
Static Puncture Resistance |
pass |
pass |
pass |
15 |
Dynamic Puncture Resistance |
passC |
passC |
passC |
- Q: Bathroom shower room bath, downstairs sewer near the floor of the water seepage, as shown, the most likely cause of urgency, and maintenance methods, extremely grateful
- The drain and sewer joints are partially leaking, or the sewer is broken. It is likely that the pipeline is blocked from the water, clean up after the proposed no damage to the case of tiles will be gently knock down the ground down, slowly knocked around the cement, you can see the sewer interface, if it is leaking here, with cement Mix 107 glue backfill can be. After the use of regularly clean up the sewer, because the bath can easily plug the pipeline.
- Q: Does anyone know how to compare the shower room?
- Comparison, design and quality, in both these are better, Rose Island is very good.
- Q: 1, I have 18 shower room, with the floor, intended to use three 16L gas water heater, separate equipment, one by one 6 shower. This will not be cold or hot, not even hot water? 2, if the heating speed hot water heater, the price higher, there is no other way?
- In response to this situation, in fact, the market has long been a mature program, but to increase the other accessories, which is mainly to increase a hot water tank, a tank temperature sensor, plus a constant temperature circulating pump. The hot water used by the user is from the hot water stored in the storage tank. ? According to the national standard, the standard water consumption of a shower is at 150L, and you now have 18 shower, so the total maximum water consumption is at 2700L. Approximate storage tank volume = total water consumption × (water temperature - tap water temperature) ÷ (water temperature - tap water temperature) × 70% × 1.3 = 1579.5 approximately equal to 1600L Note: The calculation is usually used, the storage temperature of 60 ℃, tap water temperature of 4 ℃, the actual water temperature of 40 ℃. 70% of the water tank for the effective water consumption, 1.3 for the tank volume factor. ? So you need to choose a 1600 liters above the storage tank, and then according to the equivalent heating power tank, choose how many gas water heater. While the 1600 storage tank, then about 250KW, it is equivalent to the need for seven 16 liters of gas water heater.
- Q: What is the size of the bathroom from the shower room and the outlet?
- No specific provisions of it, taking into account the need to install the leak, generally about 20CM.
- Q: Shower room closed or good semi-closed
- Semi-closed to prevent accidents
- Q: What is the best light? What is the light? 4 square best installed what light?
- Is the shower room installed in the bathroom? The bathroom is generally Yuba or moisture-proof and moisture-proof ceiling. Do not pretend that it is not moisture-proof anti-fog anti-fog. 4 square on Yuba ah!
- Q: When buying a shower room, the hardware handle, chute or not to calculate the other
- The complete shower room includes a variety of accessories. But some products can provide a variety of accessories to choose from, then the annex and the subject will be separately priced. For example, if the handle with stainless steel, copper, gold plating a variety of options, the price is certainly different, only another operator. As long as the time to buy clearly, when considering the total price, you can.
- Q: What is the price of a simple shower room? How to choose shower room?
- To the shower room ten brands, choose from the inside to buy will not give people cheated, of course, to buy genuine can 1 Deli shower room 2 Ideal shower room 3 Plus maple shower room 4 Furui shower room 5 Jinsha SALLY 6 Lisa ROSERY 7 Apollo Appollo 8 Wrigley ARROW 9 Kohler shower room 10 Ou Lu Sha orans
- Q: Can the washing machine be placed next to the shower room (partition)?
- Of course you can, mainly to see the space enough, my home washing machine directly to the balcony.
1. Manufacturer Overview
Location | Shandong, China |
Year Established | 2010 |
Annual Output Value | |
Main Markets | North America South America Southeast Asia Oceania Mid East Western Europe South Asia Domestic Market |
Company Certifications | ISO 9001:2008 CE |
2. Manufacturer Certificates
a) Certification Name | |
Range | |
Reference | |
Validity Period |
3. Manufacturer Capability
a) Trade Capacity | |
Nearest Port | QINGDAO,TIANJIN,SHANGHAI |
Export Percentage | 51% - 60% |
No.of Employees in Trade Department | 6-10 People |
Language Spoken: | English, Chinese, Japanese |
b) Factory Information | |
Factory Size: | above 2000 square meters |
No. of Production Lines | |
Contract Manufacturing | |
Product Price Range |
Send your message to us
Non Exposure Homogenous PVC Membrane for Roofing with Backing 2.0mm
- Loading Port:
- China Main Port
- Payment Terms:
- TT or LC
- Min Order Qty:
- 1000 Square Meters m²
- Supply Capability:
- 200000 Square Meters per Week m²/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches