• Maglev Wind Power Solar Wind Powered Street Lights System 1
  • Maglev Wind Power Solar Wind Powered Street Lights System 2
Maglev Wind Power Solar Wind Powered Street Lights

Maglev Wind Power Solar Wind Powered Street Lights

Ref Price:
get latest price
Loading Port:
Shekou
Payment Terms:
TT or LC
Min Order Qty:
-
Supply Capability:
2000 units / month set/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

 

 

1. Structure of  Maglev Wind Power Solar Wind Powered Street Lights

Do you want to benefits from Maglev Wind Generator ,PV Hybrid Power Lamp System?

Our maglev wind generator has 3 models, 200W, 300W, 400W for lamp application system.

 For the lamp system power supplying renewable energy, Generally the configuration as below:

 

Maglev wind generator : 300W, 24V 1 sets

Solar Panel : 120W,24V 2 pcs

Camera : 50W,24V 1 pcs for roadway ,and 25W 24V 1 pcs for the pavement.

Tower : 7.2 m

Gel Batteries : 200AH, 2 pcs

 

2. Main Features of Maglev Wind Power Solar Wind Powered Street Lights

1.     Startup at low wind speed of 1m/s

2.     Higher efficiency compared to traditional HAWT

3.     Works even in turbulence

4.     Visually pleasing appearance

5.     Turbine construction is resistant to gale 60m/s (132MPH)

6.     Robustness and adaptation to all possible environmental conditions thanks to material of aluminum alloy or stainless steel

7.     Life span: at least 20 years

 

3. Maglev Wind Power Solar Wind Powered Street Lights Images

 

Maglev Wind Power Solar Wind Powered Street Lights

 

.

 

4. Maglev Wind Power Solar Wind Powered Street Lights Specification:

 

 

Maglev wind generator

 

TypeCXF200CXF300CXF600CXF1000CXF3000
Rated Power200W300W600W1000W3000W
Size(Height / Diameter)1035/1150mm1090/1240mm1320/1540mm2200/2400mm4200/4570mm
Turbine Weight22.5KG31KG49KG180KG715KG
Blades MaterialAluminum alloyAluminum alloyaluminum alloyaluminum alloyaluminum alloy
Blades Qty.33333

Start-up

wind speed

1m/s1.3m/s1.3m/s1.5m/s1.5m/s

Cut in

wind speed

2m/s3m/s3m/s5m/s, 3.5m/s3.5m/s
Rated Wind Speed13m/s12m/s13m/s13m/s13m/s
Cut out Wind Speed16m/s15m/s15m/s15m/s15m/s
Survival Wind Speed60m/s65m/s65m/s60m/s60m/s
Generator TypeAC,3 phasesAC,3 phasesAC,3 phasesAC,3 phasesAC,3 phases
Controller output voltageDC12VDC24V/12VDC24V/12V/48VDC48V/24VDC48/96V
Controller output current<12Amp<20Amp<30Amp<50Amp<130Amp
Controller braking system

3-Phase /short circuit protection/ NFB/

Manual break or automatic brake optional

Ambient Temperature-30~50 ℃-40~50 ℃-40~50 ℃-40~50 ℃

-40~50 ℃

 

 

Rated power

Approx. 300Wh at 13 m/s (26 mph)

Swept Area

0.8 m2

Height / Diameter

1.23/1.09 m

Weight

27 kg

Shipping Dimensions

1160 x 520 x 790 mm 56 kg

Startup Wind Speed

1 m/s (2.6 mph)

Voltage

12, and 24 V AC

Turbine Controller

Smart Wind $ solar hybrid controller

Body

Permanent mold cast aluminum

Blades

(7) Injection-molded aluminum

Alternator

Permanent maglev generator

Overspeed Protection

3 phases short-circuit braking control

Survival Wind Speed

65m/s

Mount

Inner diameter 80MM 140mm outer diameter

Wind Speed Operating Range

1-15 m/s (8-49 mph)

Optimum Wind Speed Range (RPM)

8-10 m/s ( 750-800RPM)

 

5. FAQ

 

Q1: Why we use wind power for electricity generation? 

Re:Wind speeds are often low in periods (summer, eventually) when the sun resources are at their best. On the other hand, the wind is often stronger in seasons (the winter, in many cases…) when there are less sun resources.

Even during the same day, in many regions worldwide or in some periods of the year, there are different and opposite patterns in terms of wind and solar resources. And those different patterns can make the hybrid systems the best option in electricity production.

 

Q2: How is the installation of this wind turbine?

• Easy Installation: System can be assembled within one hour

• No welding

• Single or multiple unit connection for bigger power production

• Easy connection with PV systems



Q: Recently went out to do the test, do not know the difference between the two tests
Is your company product acceptance test of customer delivery, in order to find new equipment in the design, manufacture, transportation and installation in the process of diagnosis is consistent with the risks, operational conditions, testing of new equipment.
Q: The production and transportation process of electric power
The transmission voltage is the main symbol of the development level of transmission technology. By 1990s, the world's commonly used transmission voltage of 220 thousand volts and above high voltage transmission of 330 to 765 thousand volts EHV transmission, more than 1 million volts and UHV transmission. In power system, the power plant will naturally change the primary energy into electricity, and send electricity to power users far away, in order to reduce the power loss of transmission line and line impedance, voltage should be increased; in order to meet the needs of power users safe, and will reduce the voltage, and assigned to each user, this we need to raise and lower the voltage, and can change the distribution of electric power. So the substation and distribution of electric power electrical device through its transform voltage, electric power system, it is a link between power plant and power users, and through each substation voltage level of the grid connected substation function is to transform voltage, transmission and distribution of power. Substation is composed of power transformer, power distribution equipment, two system and necessary auxiliary equipment.
Q: Complete sets of power equipment life of the country what are the provisions for the aging of the equipment how to deal with, there is no standard?
Such as frequency of use, load characteristics, working environment, etc.. The service life of a certain type of equipment must refer to the specifications of the corresponding industry.
Q: What is the LCP cabinet of electric power equipment
Local control cabinetLocal control cabinet installed in the work site, which is likely to have PLC, the scope of the control cabinet than PLC wide
Q: In the communication and power equipment in the data access to a "remote message quantity" concept, then what is called "remote information", how to define it? Thank you
. When the circuit breaker is switched on, the position of the gate is the remote signal. Generally can be defined according to their needs!
Q: Generator, shunt capacitorShunt reactorShunt capacitorStatic compensator
The equipment you have listed has this function. The generator and the camera belong to the rotation compensation equipment
Q: What are the effects of frequency variation on power users and power systems?
Power frequency: generally refers to the frequency of electricity market, China's power industry, the standard frequency of 50 hz. Some countries or regions, such as the United States, are set at 60 hz.
Q: The two devices of the power system have those
Two power system equipment:An auxiliary device for monitoring, measuring, controlling, protecting and regulating the primary equipment in a power system, called a two device, that is not directly connected to the electrical energy.
Q: For example, EPS emergency power supply and so on, as well as those used in public emergencies.
The key is not the equipment problem, but to attach importance to the power emergency platform and power dispatching platformOf course, in addition to EPS lighting / power emergency power supply, there are the following emergency equipment:
Q: In power system, the general conditions for the selection of electrical equipment are
Suitable voltage rating, suitable for workplace and environment, necessary protection

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

Hot products


Hot Searches

Related keywords