Introduction of LED Glass Tube
1. Model: HDG22
2. Power: 16W
3. CCT: 3000K/4000K/6500K
4. Luminous Flux: 1600LM
5. Input Voltage: AC100-240V
6. Beam Angle: 320°
7. CRI: 70
8. Material: Glass
9. Dimension: L1200*Dia30mm
10. Lighting source: SMD2835
11. PF: 0.5
12. Certification CE, Rohs
13. Warranty: 2 Years
14. Lifespan: 15000Hrs
Application of LED Glass Tube
1. Indoor decoration
2. School/universities/hospital
3. Conference/meeting room, show room
4. Commercial complex
5. Factories/offices
6. Supermarkets
7. Residential/institution buildings
Advantage of LED Glass Tube
1.Low power consumption, high lumens
2.Original epileds 42mil led chips ,high quality, high brightness
3.Longer life lasting around 50,000hours
4.High quality pure aluminum, Efficient heat dissipation design, fast heat dissipation
5.Efficient LED driver, Reliable Performance,3C compliant
6.Product process exquisite, unique design
7.light’s surface diameter and material thickness are greater than other products on the
market
8.excellent service, comprehensive after-sales service
Packing and Shipping of LED Glass Tube
We provide professional led products packaging:
1) using appropriate package to protect the products.
2)Then with a large cardboard box.
Mode of transportation:
By Air.for small samples,we use international express delivery.
By sea.For large quantities of goods,we use container shipping.
Other ways for your needs.
Pictures of Masking Tape
Specification of LED Glass Tube
Description | LED BYPASS T8 22W 4FT. |
Voltage | 100-277V |
Power | 22W |
Lumen | 2200lm |
Length | 4 FT |
CRI | 80 |
CCT(K) | 4000K/5000K |
PF | 0.95 |
Remarks:
1.The LED Tube is used inside power driver,wide voltage available 175-220VAC,like up graph.
2.Pls pay more attention about the waterproof thing, It’s no waterproof;
3.when you install,pls take it careful,in case of hurt the tubes.
4.The ideal working for the tube is 20 centigrade,but it working temperature can wide to -40℃ to 70℃.
5.Inside the tube it have the high voltage,pls don’t open the tube for repiring if you aren’t a professional worker
Company Advantages
1. Highly experienced sales & Technical personnel;
2. We have technology engineers with more than 10 years experience in this filed & highly trained professionals QC to control the quality strictly;
3. We offer OEM/ODM service according to your design & your demand;
4. Our responsibility is to provide top quality LED lighting & reasonable prices for you to compete in your market competitively.
5. We believe that our employee's skills development to serve you better
- Q: In several production workshops of my unit, we will replace a batch of philips T5 fluorescent fluorescent lamps with LED fluorescent lamps. However, it took more than two years to get rid of the old lamp, and it was neither green nor economical, so consult the high man.
- The same way But at the moment there appears to be no systematic recycling system for fluorescent tubes
- Q: Fluorescent lamp double lamp tube wiring method
- Leds that do not normally require special orders are mostly built with built-in power, which is directly available. Most can only need to remove the starter on the traditional stent line (is a cylinder bracket highlighted below) mount tubes can be used, if not yet so could you use the stent is a relatively new "electronic" will be a little trouble need you open the stents to get inside the ballast also take off to the inside of the line directly connected to the utility, LED bulb is directly at the mains. Of course, if you understand the circuit and you're not afraid of trouble, it's advisable to remove the "regenerator", because the "ballast" is a power drain.
- Q: Can the LED tube be installed as a general lamp holder? It won't burn easily
- Cannot be installed directly, need to change internal wiring. Leds are not the same as the traditional lamp tubes, which have the power supply inside the LED tube, and the input voltage at both ends of the tube is 220V. The traditional lamp power source is placed outside, and the voltage at both ends of the lamp is as high as a few hundred volts. If the LED tube is directly installed, it will burn down the power in the LED lamp tube because of the hundreds of volts of voltage that the original fluorescent lamp's ballast outputs. 3, therefore, the LED light tube cannot be installed directly in the traditional fluorescent tubes, the need to remove the internal ballast, then change the input at the ends of the line. LED bulbs are usually two incoming lines, one firewire and one zero line.
- Q: How does the energy-saving lamp tube set quota
- For example, can be used in dome light, wall lamp, such as the above, set directly absorb dome light, wall lamp, if only is energy-saving lamp tube directly in the lamp on the mouth, can energy saving lamp holder.
- Q: What's the difference between a single input and a double-end input?
- Like our products, single side used on special occasions, be flat installation place, double side is directly used in the traditional ordinary lamp, so change the LED fluorescent lamp is very convenient.
- Q: Is a three-male LED fluorescent lamp? How the quality?
- Mitsuo LED bulb, all is by the generation of processing products LED professional production enterprises, from mitsuo buy many, you can increase the cost of quality are ok, but I still suggest you still looking for a professional do the manufacturer of LED lamps and lanterns, will reduce a lot of cost for you!
- Q: How do you know whether a fluorescent tube is good or bad
- How do you know whether a fluorescent tube is good or bad
- Q: Why does the led fluorescent tube have water vapour in it? What causes it?
- The starter down. When the regenerator was knocked down, my home was my own scissors and cut off the ends of the two ends of the regenerator. Then attach the severed head to the insulation tape. search Put the base back to the original. The head of the LED fluorescent tube will be plugged into the base current
- Q: Excuse me, the lamp in the sitting room lamp is carried good or the lamp tube is good
- Application scope of the lamp band: Has been widely used in buildings, Bridges, roads, garden, garden, floor, ceiling, furniture, steam 'car, ponds, underwater, advertising, signs, signs and other decoration and lighting, for all kinds of festivals such as Christmas, Halloween, valentine's day, Easter, added infinite joy and festive mood such as National Day, the indomitable vitality of its advertising, decoration, construction, commercial, five advantages of gift market, are widely used in building contour, bridge, fence, decoration to the hotel, the grove, dance hall, advertising
- Q: Why don't leds need a rectifier
- Leds are dc driven, and they don't need a rectifier. In addition, it will also affect the life of LED tubes
Send your message to us
LED Glass Tube 160CM 1600LM 320 Degree Beam Angle
- Loading Port:
- Shanghai
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 1000 pc
- Supply Capability:
- 20000 pc/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches
Related keywords