High Luminous CE RoHS Approved T8 Led Light Tube 11w with T8-0.6m-B1-9W
- Loading Port:
- Guangzhou
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 2 pc
- Supply Capability:
- 10000 pc/month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
Product detail
1. Shell: aluminum alloy materials with standard T8 specification, PC cover with milky white
2. Light source: with low attenuation process encapsulation of the LED white light
3. Power supply: constant current; protection of over-current, over-voltage and high temperature, to ensure the products stable performance
4. Perfect lighting effect, fast starting, low power consumption, no ultraviolet and infrared radiation
Tag: LED Tube | T8 LED Tube light | 3014smd led tube | led tube light | led light tube 11w
Why will you choose okorder?
1. Provide professional person to communicate with you before the order.
2. Provide permanent magnet generator with advanced technology, exquisite workmanship, top design.
3. Provide strict quality check for each part, each process before export.
4. Provide optimum system solution based on each client’s specific requirement and local location’s weather condition.
5. Provide complete post-sale service, including installation, technical guide and training.
Our service:
1. Qkorder products are certificated with optimization with higher brightness for led chips, upgraded lens, higher efficient drivers etc.
2.Professional service from well-trained and experienced staffs is customers’ best choice to secure good communication, on time delivery, reliable warranty etc.
3.OEM is available for okorder Products.
4.Relative certification is provided for European and American market.
Advantage:
We mainly manufacture T5 and T8 LED Light Tubes from 3W to 25W, 18W T8 are the most popular LED Tubes. The most LED Tubes input voltage is AC85-265V, but the T8 SMD3014 series is AC86-AC260V. LED Light Tubes are very suitable to replace fluorescent tubes and wildly used in super market, parking area, office building etc because you can save about half of the power if you use LED Light Tubes.
Terms and Conditions
1. Above prices are based on FOB Guangzhou in USD.
2. MOQ: 100PCS. For less than 100pcs, price needs be increased by 20%.
3. Warranty: 2 years. All LED tubes adopt high-quality LEDs, with service lifetime of over 40,000 hours.
4. Delivery time: For 500pcs, goods can be finished within 15 days upon down payment receiving.
- Q: The two ballast that originally was electric inductance towed three ordinary fluorescent lamps, now changed to LED fluorescent lamp tube, have influence?
- The impact is certain, and it wastes electricity. It is expected to waste about 12W of power, and if it is powered by a capacitor, it will also greatly affect the brightness.
- Q: How many lumens is the T5 bulb of 18W
- Look like you do with t5 example, t5 strengths, now, now is from inductance rectifier to improve the electronic rectifier, higher efficiency, lamp lumens not only meet the even more than the national standard, reached about 90 lumens. And t5 is more efficient!
- Q: What is the weight of an LED fluorescent tube
- I bought the T8LED fluorescent lamp from Shanghai shuo electronics co., LTD., which is 536 grams
- Q: Can normal LED fluorescent tubes be used in a vacuum?
- Can normal LED fluorescent tubes be used in a vacuum?
- Q: Help me see the yellow on the left side of the LED fluorescent lamp
- It should be a stabilizer module; The other, the left, 1, 3 is the inductor. 4, 5, 9 is the filter capacitor; 6 is also a capacitor; 7 is a triode; 8 is the transformer.
- Q: What is the minimum starting voltage for the fluorescent tube?
- The fluorescent lamp is under the influence of the ballast, the voltage is 810 volts. 810 volts is transient and can only be observed with a digital oscilloscope. I measured the data in three different meters, and the data doesn't really have the same data.
- Q: Is there a greater value in switching from a normal daylight lamp to an LED energy-saving lamp?
- I can give you a detailed example of your problem: LED fluorescent lamp tube 6w can replace the normal daylight lamp tube 20w, 9w can replace 30w, 12w can replace 40w, 15W replace 45W, 18w can replace 60w, save more than 70% electricity; LED life can theoretically reach 5-100,000 hours, nearly 10 years. Q: how much electricity do you need a year if your company owns 10,000 40W, regular daylight bulbs (plus a rectifier, for example, 46-49 watts)? A: common light bulb: 365 days * 15 hours * 46w * 10,000 lamp tube / 1000W (1 hour) * charge 1 yuan = 2518500 yuan. LED bulbs: 365 days * 15 hours * 12W * 10,000 tubes / 1000W (1 hour) * charge 1 yuan/degree = 657,000 yuan. On the data, the cost can be recouped within a year, saving as much as $3 million in electricity bills within three years.
- Q: What specification does daylight lamp tube have, what brand of fluorescent lamp?
- TCL lighting (TCL group's famous lighting brand, building electrical design trust products, one of the leading enterprises of energy-saving lighting, TCL lighting co., LTD.) Knowledge about the fluorescent tube is introduced to the above, this hint: fluorescent lamp when use, must not wipe with wet cloth tubes, to prevent electric shock accidents.
- Q: What is the connection of the LEDT5 lamp tube, the main line is how to connect, only to the end
- 1, the installation: The LED comes with a constant current source, which does not require a ballast and a regenerator. General T8 lamp tube because the lamp tube space is big enough, constant current source can be installed in the lamp tube. So, when installing, you can remove the ballast from the original frame and remove it, and install it directly. T5 fluorescent lamp, T4LED because tubes is very small, not put constant current source, can only be constant current source in a scaffold, so, T4 / T5 general manufacturers are doing, will deploy stents, stent in persistence current source, and the lamp installation direction of the. The direction is reversed, the lamp is not bright. We are considering adding some switching circuits to allow the lamp to work properly even if the lamp is in reverse. Voltage: to communicate 85V -- communicate 245V, all can work normally. However, the long-term voltage is too high or too low, which can affect the power factor of the constant current source, which means that the effect of energy saving will be slightly affected. At the same time, it can also affect the lifetime of the constant current. So, want to choose the fluorescent lamp that is appropriate voltage commonly.
- Q: How do LED lamp tube install how connection?
- If you have a regenerator, you can simply unplug the LED, and if you don't have a regenerator, you need to remove the electronic ballast, which is a hassle
Send your message to us
High Luminous CE RoHS Approved T8 Led Light Tube 11w with T8-0.6m-B1-9W
- Loading Port:
- Guangzhou
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 2 pc
- Supply Capability:
- 10000 pc/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches
Related keywords