IZ-BL series
- Loading Port:
- China Main Port
- Payment Terms:
- TT OR LC
- Min Order Qty:
- -
- Supply Capability:
- -
OKorder Service Pledge
Quality Product, Order Online Tracking, Timely Delivery
OKorder Financial Service
Credit Rating, Credit Services, Credit Purchasing
You Might Also Like
IZ(BL)-Series
IZ (BL)-type pumps are single stage centrifugal pump direct connection for the delivery of physical and chemical properties of water or other liquid similar to water with a temperature not higher than 80 ℃. The pump is a form of small, light weight, simple structure, low noise, and easy assembly and disassembly. Shaft seal mechanical seal, seal. Applicable to factories, mines, urban water supply and drainage, high-rise building pressurized water and irrigation.Motor power:1.5-7.5kw,Flow:11.8-50m/h,Head:17.6-32m。
■List of performance | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
- Q: Fire hydrant pump button, under what circumstances do not need to install?
- The installation of hydrant pump buttons depends on the type of water supply:(1) municipal water supply; (in this case, do not have to install)(2) there is a fire pump; (must be installed)
- Q: What are the uses and precautions of magnetic pumps?
- Installation and use of magnetic pumps:1, the magnetic pump should be installed horizontally, should not be erected, the plastic pump body can not bear the weight of the pipeline, for the special requirements of vertical installation occasions, the motor must be facing up;
- Q: Rotary vacuum pump does not meet the requirements of vacuum, what are the reasons?
- 1) oil rotary vane vacuum pump is too low, no effect on the oil seal exhaust valve, rotary plug to refuel after large exhaust sound, and oil mist, that the level is too low, the gas can be eliminated.(2) the vacuum caused by the condensable steam pollution of oil should be changed, and new vacuum pump oil should be replaced.
- Q: Must the water pump in the tank be all soaked in water?
- Usually you have to soak it all in the water. If you don't want to put it in the water, you can buy an amphibious pump. At most, you can expose it
- Q: What are the general water pump failure, how to repair?
- Two, pump speed is low(1) human factors. Some users because of original motor damage, may be accompanied by another motor, resulting in a flow of small, low head or even the consequences of Sheung shui.(2) the mechanical failure of the pump itself. Impeller and pump shaft fastening nut loose or deformation of the pump shaft bending, resulting in multi impeller, directly with the pump body friction, or bearing damage, are likely to reduce the pump speed.(3) the maintenance of the power machine is not working. The motor is lost because of winding burn, the change of winding number, wire diameter, wiring method, or failure in maintenance can not change the pump speed.
- Q: There are 6 pumps, two indoor fire hydrant pumps, two spray pumps, two outdoor pumps, three units, one master and one spare control cabinet. From the control room to the control cabinet, is there only 3 lines or 9 lines?... How do I get it? Where does the hydrant line come from?
- You said the three line refers to the control room, the control cabinet, the main pump directly start the straight line of water pump. Each pump should be equipped with single straight line Kai, reported that the cabinet Jinglian dynamic multi line linkage control board has three buttons corresponding to a remote spray pump, fire hydrant pump, pump start outdoor fire hydrant. This requires three straight lines, from the cabinet to the three pump control cabinet, which is the 9 line you call. The water pump control cabinet is provided with a terminal for supplying a remote pump. By looking at the wiring diagram of the water pump control box, you can find the technical personnel of the control cabinet manufacturer if you can't find them.
- Q: Pump unloading in hydraulic transmission,
- Can be used for short-term shutdown, pump non-stopNo unloading, usually through the overflow valve back to the tank, high pressure, power, at this time insurable pressure, and so on
- Q: What does "efficiency" mean in a water pump catalog?
- The efficiency of the water pump nameplate refers to the maximum efficiency that the pump can reach at the rated speed
- Q: How many square cables does the submersible pump for 7.5KW need?
- According to current I=13A, it is estimated that the cable is less than 10 square meters, so the cable cross section can be calculated at the ampacity of 5A per square meter. The square section of the cable is =13/5=2.6 square. According to the specifications series, optional 2.5 square aluminum cables. When the cable is longer, it is safer to choose 4 square aluminum cables.
- Q: What is an industrial water pump?
- Classification by usagePump, circulating pump, fire pump, pressure test pump, sewage pump, metering pump, sanitary pump, dosing pump, pump, pump, gelatinization defoaming pump, flow pump, oil pump, water pump, drainage pump, drainage pump, dredging pump, sprinkler pump, booster pump, high pressure pump, heat pump high temperature, low temperature, pump pump, condensate pump, heat pump, cooling pump, heating pump, deep well pump, analgesic pump, pump, pump, chemotherapy, blood pump material pumping pump, pump, pump, sulfur removal, shearing grinding pump fuel pump, pump, pump, quillback bath source heat pump, filter pump oxygen pump, pump, shampoo, injection pump, air pump, gas pump, pump, pump, art odorization pump chopped
Send your message to us
IZ-BL series
- Loading Port:
- China Main Port
- Payment Terms:
- TT OR LC
- Min Order Qty:
- -
- Supply Capability:
- -
OKorder Service Pledge
Quality Product, Order Online Tracking, Timely Delivery
OKorder Financial Service
Credit Rating, Credit Services, Credit Purchasing
Similar products
Hot products
Hot Searches