Flexible Duct Pipe - Hot Selling Steel Wire
- Loading Port:
- China Main Port
- Payment Terms:
- TT OR LC
- Min Order Qty:
- -
- Supply Capability:
- -
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
Specifications
1. high carbon spring wire
2. Wire dia:0.4-13mm
3 .Standard:DIN17223 GB4357-89
4 .Delivery time:15 days 1*20FCL
5 .MOQ:1 Ton
1. Specification
Material | 45#,60#, 65#, 65Mn, 70#, 72A, 72B, 80#, 82B,SAE1060, SAE1065, SAE1070 |
Dia | 0.3-13.0mm |
Surface | Smooth, phosphated and lead patent heat treatment |
Quality inspection of each coil | Tensile Strength, Tolerance, Surface smooth, Torsion,Bending,Winding, Ellipse , etc. |
Certificate | ISO9001,ISO14001,SGS,Jiangsu Famous Brand , Excellent Quality Metallurgical Products |
Standard | DIN17223/1-1982,GB4357-89 and other standards . |
Application | making springs, steel ropes, cable wires, mattress ,banding wire |
Coil weight | 15KG-200KG per coil or as per your requirement |
Packaging | coils, packed with P.P.cloth or according to customers' request. |
Dilivery time | 15 days for one 20 feet container. |
Loading Capacity | Loading about 20tons in one 20's containe |
Tensile Strength
High Carbon Steel Wire | |||
wire diameter(mm) | Tensile Strength(N/mm² ) | ||
Grade B | Grade C | Grade D | |
0.20 | 2150-2550 | 2400-2790 | 2690-3090 |
0.25 | 2060-2450 | 2300-2700 | 2640-3040 |
0.30 | 2010-2400 | 2300-2700 | 2640-3040 |
0.40 | 1910-2300 | 2250-2650 | 2600-2990 |
0.50 | 1860-2260 | 2200-2600 | 2550-2940 |
0.60 | 1760-2160 | 2110-2550 | 2450-2840 |
0.70 | 1710-2110 | 2060-2450 | 2450-2840 |
0.80 | 1710-2060 | 2010-2400 | 2400-2840 |
1.00 | 1600-2010 | 1960-2300 | 2300-2690 |
1.20 | 1620-1910 | 1910-2250 | 2250-2550 |
1.40 | 1620-1910 | 1860-2110 | 2150-2450 |
1.60 | 1570-1860 | 1810-2160 | 2110-2400 |
1.80 | 1520-1810 | 1760-2110 | 2010-2300 |
2.00 | 1470-1760 | 1710-2010 | 1910-2200 |
2.20 | 1420-1710 | 1660-1960 | 1810-2110 |
3.00 | 1370-1670 | 1570-1860 | 1710-1960 |
4.00 | 1320-1570 | 1520-1760 | 1620-1860 |
5.00 | 1320-1570 | 1470-1710 | 1570-1810 |
6.00 | 1220-1470 | 1420-1660 | 1520-1760 |
7.00 | 1170-1420 | 1370-1570 |
|
8.00 | 1170-1420 | 1370-1570 |
|
9.00 | 1130-1320 | 1320-1520 |
|
10.00 | 1130-1320 | 1320-1520 |
|
11.00 | 1080-1270 | 1270-1470 |
|
12.00 | 1080-1270 | 1270-1470 |
|
13.00 | 1030-1220 | 1220-1420 | |
*Chemical Composition
Steel Grade GB Standard | Carbon % | Silicon % | Manganese % | Phosphorus % | Sulphur % | Chromium % | Nickel % | Cuprum % |
60# | 0.60-0.61 | 0.18-0.22 | 0.52-0.59 | 0.012 | 0.007 | 0.06-0.07 | 0.05 | 0.18 |
65# | 0.65 | 0.21 | 0.56 | 0.013 | 0.008 | 0.05 | 0.04 | 0.14 |
65Mn | 0.60-0.70 | 0.10-0.25 | 0.70-1.00 | 0.030 | 0.030 | 0.20 | 0.20 | 0.25 |
70# | 0.69-0.71 | 0.19-0.21 | 0.53-0.58 | 0.010-0.012 | 0.003-0.006 | 0.01-0.05 | 0.02-0.04 | 0.04 |
72A 72B | 0.72 | 0.19 | 0.71 | 0.013 | 0.006 | 0.02 | 0.02 | 0.03 |
80# | 0.80-0.81 | 0.22-0.24 | 0.59-0.76 | 0.008 | 0.004 | 0.04 |
|
|
82A 82B | 0.82 | 0.24-0.25 | 0.76-0.77 | 0.011-0.014 | 0.004-0.007 | 0.17-0.17 |
| |
2. Packing
Small coil or large coil for the steel wire : Coils, packed with P.P.cloth or according to customers' request
Z2 packing :200-350KF per coil
Iron spool or wood spool for the steel wire
3. Our service
Sample order: we supply you free sample, you pay for the express cost, which can be shipped in 3 days
Our promise: Send you a workable price ;
Delivery in time;
Service you in lifetime for free;
Full refund if substandard goods
- Q: Will metal hose be used on the wastewater treatment equipment?
- Code Subhead Name Engineering Value Value (RMB) Where (unit) Unit Quantity Unit Price Proportion Labor Cost Material Cost 11-26 Earthwork Artificial Trenching Pit excavation pit three types of soil depth within 2m 100m31
- Q: For example, HDPE pipe with a flexible connection is a flexible interface, PVC-U of the glue plug-in method, is just helium pouring a lie on the pizza pull the interface, wire then, flange it more
- Project Name: Construction Lifting Machinery Safety Supervision and Management Provisions Expiry date: June
- Q: We now have to declare the Department of the Ministry of the United States and the United States, the company said that the access point to our own set, so I would like to ask, what is the requirements of this access point? There is no relevant specification to add: is the construction, the outdoor pipe network in the gas access point position more
- The cost of the main cantilever is as low as the secondary structure can be moved
- Q: What is the difference between a flexible pipe and a rigid pipe? What types of pipes are used for drainage pipes, heat pipes and gas pipelines?
- From the environmental point of view and save the cycle of insulation coating is good, insulation coatings can be divided into internal and external insulation and other products
- Q: Will the embedded stove why use stainless steel corrugated hose connection?
- Do not open the window, enjoy the fresh air 24 hours a day, to ensure adequate ventilation (hourly indoor air replacement 0
- Q: The sound of water pipes will not produce infrasound damage to the human body?
- The general pipe and pipe material to connect manufacturers to supply matching, so that more to ensure quality
- Q: What are the scope of construction work special operators?
- This look at their own interest, ah, I was learning mechanical, or from the mechanical drawing began, in the study of tolerance, technology, design, etc., there are many, but also learn a three-dimensional software, like proe
- Q: Find a joint electronic M1.5.4 type ECU application system wiring harness and layout Thank you, anxious! The
- According to the intrinsic composition of insulation materials can be divided into: inorganic insulation materials and organic insulation materials! Fire rating A is a non-burning point with the insulation effect of materials, materials. Class A non-combustible materials have the characteristics of low density, low thermal conductivity, high pressure capacity, convenient construction, economical and durable. They are widely used in thermal insulation materials and industrial industries such as hot pipes, thermal equipment and other industrial piping equipment and industrial buildings And the civil building envelope structure of the insulation, insulation, sound absorption materials. Because of its good thermal stability, and more for the steel structure of the fire protection coating material. Fire rating B1 level is a flame retardant insulation material, is determined according to the fire resistance of the material, in addition, different parts of the material division is also different! Burning performance: refers to the material and / or products in case of fire burning all the physical and / or chemical changes, that is, the fire reaction characteristics. Fire rating B2 is a combustible insulation material also known as flame retardant materials, mostly organic insulation materials, add the right amount of flame retardants. More common for EPS expansion polystyrene board and XPS extruded polystyrene board, that is, we often say that general board. This material is low in ignition and releases a lot of harmful gases during the combustion process. Fire rating B3 is a flammable insulation material, this is more common as the main material of polystyrene foam insulation material, because this material is easy to burn,
- Q: To ask why the use of clamps connected to the spray pipe after the flush again after the water there will be a lot of hook link position leakage phenomenon? Thank you! The The
- The radial force of the seal is far greater than the axial force of the connecting bolts but all the axial force washers 窢 field urging 讵 peculiar aldehyde support, good self-sealing effect by the pipeline through the media rubber ring pressing force pressure more sealing performance of the more pressure to prevent the pressure of the rubber ring to the inner diameter of the tube end of the interface diameter Preload to prevent the media pressure leakage and the blue compared to the higher the pressure of the pipe the more the advantages of the more dangerous the pipe junction at the flexible state of the clamp and the tube between the gap between the clamp clamp a small number of adjacent pipe to allow the corner tube Pipe pipe between the end of the gap to allow the axial shift of the pipeline to adapt to the expansion and contraction of the pipe; pipe interlocking effect reduced 70% mechanical vibration
- Q: Rigid pipes differ from flexible piping, those are rigid pipes that are flexible piping
- First of all, the main structure of the construction to be reserved when the knot point, and then with the foot of the lack of rush to maintain the use of steel pipe, the so-called hard link. Combined with the external wall fastener type steel scaffolding specifications
Send your message to us
Flexible Duct Pipe - Hot Selling Steel Wire
- Loading Port:
- China Main Port
- Payment Terms:
- TT OR LC
- Min Order Qty:
- -
- Supply Capability:
- -
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches
Related keywords