High Temperature VRLA Batteries, GFMH Series

Overview

  • Positive plate: Thick high Sn low Ca grid minimize corrosion and prolong life

  • Negative plate: Balanced Pb-Ca grid for improved recombination efficiency

  • Separator: Advanced AGM separator for ultra low float current

  • Electrolyte: nano Silicon GEL electrolyte import from Evonik Degussa Germany.

  • Battery container and cover: fire resistance ABS for higher temperature

  • Pillar seal: 100% factory tested, proven two layers epoxy resin seal

  • Relief valve : Complete with integrated flame arrestor

Applications for High temperature deep cycle gel batteries 

  • BTS Stations

  • Solar & Wind energy system

  • UPS system

  • Mrine system

  • Golf Cart&Electric Wheels

  • Other power system


Features:

GFMH battery has got wide temperature range and outstanding high temperature performance. It can be used in a range of -25 ℃ ~ + 75 , and it can be long-term use in a range of 15 ~ 40 ℃.



Maintenance and Attention Matters

1.Don’t near the hot source and don’t under the sunshine.

2.Don’t charge in the sealed container.

3.No short circuit. It should be addition charge if you don’t use, and single charge per three months, to avoid irreversible  sulfuring.

4.The battery should be changed when the battery jar broken or the electrolyte omitted, to avoid acid corrosion.

5.Don’t store in the space of acid gas.

6.You should be careful and regular check when use the battery. To avoid the battery don’t work. You should change the battery if the capacity is not full or has been damage, especially after one year using.

7.Don’t put the battery in the fire, or it will explode.

8.Please use cotton cloth to clean, if the battery is broken down and leak electrolyte. Please wash your skin when touch the electrolyte.

9.Don’t clean the battery by using the organic solution. (e.g. petrol) 





front terminal 12V 200AH high  temperature battery


front terminal 12V 200AH high  temperature battery


Q: How to repair the battery?
Connect the positive and negative output of the repair instrument to the positive and negative pole of the battery, open the repair instrument, repair the battery. The first repair time should be no less than 48 hours.
Q: How is the capacity of the battery defined?
100AH capacity of the battery, fully charged after the 100A current discharge can be an hour to put the power finished. 50A current is 2 hours put away! 20A is 5 hours! Of course this is the theoretical value, in fact it is impossible to have a constant current discharge.
Q: How to determine the battery is good or bad?
If less than 9V but the pointer is in a certain value does not move that the battery is in a state of loss, need to add charge.
Q: How to deal with waste batteries?
In addition to lead-acid batteries, all kinds of batteries are dissolved in sulfuric acid, and then by means of ion resin from the solution to extract a variety of metals, raw materials obtained in this way than the heat treatment method is pure, so the market price is higher, and the battery contains 95% of the various substances can be extracted.
Q: What are the advantages of maintenance-free batteries?
Maintenance-free battery because of its normal charging voltage, the electrolyte only produce a small amount of gas, so throughout the use of the need for the addition of distilled water, in the normal charging system, do not need to remove the charge from the removal. But in the maintenance of the proportion of its electrolyte should be checked.
Q: What is the meaning of the battery above 12v65Ah?
12V represents the rated voltage. 65Ah indicates that the battery capacity (ie 1 ampere current can be used for 65 hours).
Q: 80ah how much battery storage capacity?
The size of the battery storage power refers to the battery capacity. Battery capacity is generally calculated in AH (safety). You 80Ah battery capacity is 80Ah, meaning that if you discharge current to 80A, you can put an hour.
Q: The role of the battery?
Battery is a kind of battery, its role is to be able to save the limited power, in the right place to make 6v4ah emergency light battery. Its working principle is to convert chemical energy into electricity.
Q: What kind of battery is divided into?
At present, we used the car battery is divided into three categories, namely, ordinary batteries, dry batteries and maintenance-free batteries three.
Q: Lead-acid battery how to maintain?
After passing the test, cover the exhaust cutting, pay attention to restore the filler, cover the battery cover, if the cover is glued, then glue bonding.

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

Hot products


Hot Searches

Related keywords