High Temperature VRLA Batteries, GFMH Series

Overview

  • Positive plate: Thick high Sn low Ca grid minimize corrosion and prolong life

  • Negative plate: Balanced Pb-Ca grid for improved recombination efficiency

  • Separator: Advanced AGM separator for ultra low float current

  • Electrolyte: nano Silicon GEL electrolyte import from Evonik Degussa Germany.

  • Battery container and cover: fire resistance ABS for higher temperature

  • Pillar seal: 100% factory tested, proven two layers epoxy resin seal

  • Relief valve : Complete with integrated flame arrestor

Applications for High temperature deep cycle gel batteries 

  • BTS Stations

  • Solar & Wind energy system

  • UPS system

  • Mrine system

  • Golf Cart&Electric Wheels

  • Other power system


Features:

GFMH battery has got wide temperature range and outstanding high temperature performance. It can be used in a range of -25 ℃ ~ + 75 , and it can be long-term use in a range of 15 ~ 40 ℃.



Maintenance and Attention Matters

1.Don’t near the hot source and don’t under the sunshine.

2.Don’t charge in the sealed container.

3.No short circuit. It should be addition charge if you don’t use, and single charge per three months, to avoid irreversible  sulfuring.

4.The battery should be changed when the battery jar broken or the electrolyte omitted, to avoid acid corrosion.

5.Don’t store in the space of acid gas.

6.You should be careful and regular check when use the battery. To avoid the battery don’t work. You should change the battery if the capacity is not full or has been damage, especially after one year using.

7.Don’t put the battery in the fire, or it will explode.

8.Please use cotton cloth to clean, if the battery is broken down and leak electrolyte. Please wash your skin when touch the electrolyte.

9.Don’t clean the battery by using the organic solution. (e.g. petrol) 





front terminal 12V 200AH high  temperature battery


front terminal 12V 200AH high  temperature battery


Q:80ah how much battery storage capacity?
0AH storage is 80AH ah If the actual storage capacity will have to see the brand. I have seen 100AH only 24 pound. This is not even 60AH.
Q:What kind of battery is divided into?
Ordinary battery: ordinary battery plate is composed of lead and lead oxide, the electrolyte is sulfuric acid aqueous solution. Its main advantage is the voltage stability, the price is cheap.
Q:How to determine the battery is good or bad?
Instrument test: the general use of battery discharge tester, the test instrument two positive and negative clamp were holding the battery positive and negative electrodes, press the test button to observe the test instrument instructions.
Q:Lead-acid battery how to maintain?
After 5 hours of repair, the excess electrolyte is sucked out with a straw, and if the electrolyte is sucked out into black, it indicates that the battery is severely grounded and that the battery is difficult to repair.
Q:How does the battery increase the voltage?
Chemical energy can be converted into electrical energy device called chemical battery, generally referred to as the battery. After discharge, the internal active material can be regenerated by charging - the electrical energy stored as chemical energy; chemical energy can be converted to electrical energy again when the discharge is required. This type of battery is called a battery (Storage Battery), also known as secondary battery.
Q:How to repair the battery?
Charge the battery at constant voltage. It is the beginning of the time, using 0.1C ~ 0.25C current charge, to 16.2V later, by reducing the current method to maintain the charging voltage, until the charge current drops to 0.03C when the stop charging.
Q:What are the advantages of maintenance-free batteries?
The advantage of a maintenance-free battery is that the service life is twice as long as the dry battery! And in the use of the process without maintenance! The voltage is also relatively stable.
Q:How is the capacity of the battery defined?
The capacity of the battery unit is AH (safety) is the product of current and time.
Q:How to deal with waste batteries?
The rest of the various types of waste batteries are generally shipped to a special toxic, hazardous landfill, but this approach not only cost too much but also cause waste, because there are many useful raw materials available.
Q:Battery 200ah / 104 what does that mean?
This should be refers to 2V200AH battery 104, power with the 220V. Lead-acid battery nominal voltage is 2V / (each or monomer), but in fact will be higher than 2V, so the actual use and charging equipment for the matching will use 104, also useful 103, also useful 108 Only.

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

Hot products


Hot Searches

Related keywords