Range summary
313K Series batteries are designed for high-temperature environment and new energy such as wind energy, photovoltaic energy storage system. With high temperature resistance, long life, safety and reliability characteristics, 313K series is widely used in telecommunications, electric power, energy storage, and it ideal for cycle or hybrid system in harsh, high temperature environment.
The 313K series batteries are ensured the quality with NARADA's QA system according to the ISO9001&ISO14001 standard.
Features and Benefits
1. Patented anti-corrosion grid technology
2. Optimized active material for high temperature conditions
3. Unique high temperature case material with HDT in excess of 124oC
4. Increased internal compression for improved cycling endurance
5. Oxygen catalyst to reduce float currents and extend cycling capability
6. Containers & lids UL94 V-0 rated
7. Advanced negative plate protection system
8. Wide operating temperature range:-40oC to +80oC
9. Normal operating temperature is 35oC
10. Excellent deep cycling capability systems
11. Suitable for continuous operation at temperatures in excess of 35oC
12. Reduced system operating costs 25% electricity power saving
13. Up to 100% air conditioner maintenance saving
14. Up to 100% condensing agent saving
15. 30% CO2 gas emission reduce
16. Less than 1 year payback period depend on environment
Compliant standards
1. IEC60896-21/22
2. IEC61427
3. BS6290 part 4
4. Telcordia SR4228
5. Eurobat guide
6. UL
7. Manufactured under system ISO9001(TUV) and ISO14001
Battery installation compliant with:
1. EN 50272-2 or local equivalents
Main applications
1. Hybrid telecom remote base stations
2. Renewable energy wind & solar sites
3. Grid frequency leveling systems
4. All back-up applications where grid reliability is poor
5. All extreme environment off-grid
Products characteristics:
1. Recommended float charge voltage for 2V battery: 2.24Vpc at 35oC(95oF), 2.27Vpc at 25oC(77oF)
2. Self discharge rate :<5% per month at 35oC(95oF)
3. Design life: 15 years at 35oC (95oF)
4. VRLA high temperature battery, no water addition required
Technical Data:
- Q: What is the difference between a maintenance-free battery and a conventional battery?
- Lead-acid battery is composed of positive and negative plates, partitions, shell, electrolyte and wiring pile head and other components, the discharge of the chemical reaction is to rely on positive electrode active substances (lead dioxide and lead) and negative plate active substances (sponge Pure lead) in the electrolyte (dilute sulfuric acid solution) under the action, which plate grid, the traditional battery lead and antimony alloy manufacturing, maintenance-free battery is made of lead calcium alloy, the former with antimony, the latter with calcium, This is the fundamental difference between the two points.
- Q: Maintenance-free battery how to detect it?
- When using a maintenance-free battery, it is easy to think that maintenance-free is the idea that no maintenance is required. Maintenance-free Although maintenance costs and times can be reduced, but for the appearance of the clean-up is essential, so that "maintenance-free" more point to the battery inside.
- Q: What are the advantages of maintenance-free batteries?
- Maintenance-free battery because of its normal charging voltage, the electrolyte only produce a small amount of gas, so throughout the use of the need for the addition of distilled water, in the normal charging system, do not need to remove the charge from the removal. But in the maintenance of the proportion of its electrolyte should be checked.
- Q: What is the meaning of the battery above 12v65Ah?
- Voltage 12V, current 65AH, that is the capacity of 65A. (A is the unit of current. H is the time unit)
- Q: The role of the battery?
- It filled with lead plate filled with sponge lead as a negative electrode, filled with lead dioxide lead dioxide as a positive electrode, and with 22 to 28% dilute sulfuric acid as electrolyte. In the charge, the electrical energy into chemical energy, the discharge of chemical energy and into electrical energy.
- Q: What kind of battery is divided into?
- Maintenance-free battery due to its own structure on the advantages of electrolyte consumption is very small, in the life of the basic need not add distilled water. It also has a shock, high temperature, small size, self-discharge characteristics of the general life is generally ordinary Twice the battery. There are two kinds of maintenance-free batteries on the market.
- Q: How does the battery increase the voltage?
- The so-called battery is the storage of chemical energy, if necessary, the release of electrical energy of an electrical chemical equipment.
- Q: What is a maintenanceable battery?
- This is relative to a maintenance-free battery. Maintenance of the battery needs to be supplemented with electrolyte to ensure work, while maintenance-free is not required.
- Q: Battery 200ah / 104 what does that mean?
- Lead-acid battery nominal voltage is 2V / (each or monomer), but in fact will be higher than 2V, so the actual use and charging equipment for the matching will use 104, also useful 103, also useful 108 Only.
- Q: Lead-acid battery how to maintain?
- After passing the test, cover the exhaust cutting, pay attention to restore the filler, cover the battery cover, if the cover is glued, then glue bonding.
Send your message to us
Battery Solar Wind Power System High Temperature 2V 200AH
- Loading Port:
- Shanghai
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 10 pc
- Supply Capability:
- 1000 pc/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches
Related keywords