Quick Details of Fire Alarm Control Panel

Place of Origin:

 China (Mainland)

Primary Power Supply:

120V or 220VAC 50/60Hz

Standby Batteries:

DC24V 4AH sealed rechargeable batteries

Display:

15 lines x 40 characters LCD

Devices per loop:

192 sensors & modules

 

Specifications of Fire Alarm Control Panel

Addressable Fire Alarm Control Panel
Primary Power Supply: 120V or 220VAC 50/60Hz
Standby Batteries: DC24V 4AH seale

Addressable Fire Alarm Control Panel

Specifications

The powerful OZH4800E addressable fire alarm panel contains 2, 4, 6 or 8 SLC loops with each loop supporting 192 devices.

Primary Power Supply: 120V or 220VAC  50/60Hz       

Standby Batteries: DC24V 4AH sealed rechargeable batteries

Power Supply Output: 24VDC @ 5.0 Amps (4 Amps available for system power)

Display: 15 lines x 40 characters LCD (600 characters total)

 

SLC loops: 2, 4, 6 or 8 (class A, "style 6 or 7" or class B, "style 4")

Devices per loop: 192 sensors & modules

Addresses per panel: 1536 max.

Communication Port: RS232/RS485

Operation Temperature: 10°C~+50°C  Related Humidity: ≤95% (40±2°C)

Dimensions (D * W * H): 110×335×435mm   

Weight: 16Kg.

 

Applictations of Fire Alarm Control Panel

 

The OZH4800E control panel is an analog addressable fire alarm panel using the latest 32 bit microprocessor technology and containing 2, 4, 6 or 8 SLC loops with each loop supporting 192 devices of any combination (sensors or modules). Communication between devices is transferred through standard cable (shielded or twisted pair is not required). Each panel includes a 5.0 amp power supply, 600 characters LCD display, 29 large easy-to-use tactile touchpad for system operation, programming and maintenance, 12 state indicators and a RS232/RS485 communication port. System operations include silencing alarms and troubles, resetting system and manual starting/stopping field equipment. The system's non-volatile event history buffer stores 9999 events for viewing. The system supports a variety of Orena devices: smoke and heat sensors, manual call points, contact input (monitor) modules, relay output modules, dual input/output modules, and short circuit isolator modules. In addition, interfaces to conventional detection systems can be established by using a conventional zone-monitoring module. The basic system can be expanded by adding OZF-LCD remote annunciator, OZH48ZL signalling line circuit expander, and optional mini-printer (for printing system reports). The intelligent panel and detectors know the difference between a fire and a dirty sensor. It lets you tailor sensor sensitivity and gives you immediate, pinpoint accuracy for any condition. The powerful OZH4800E system provides you with revolutionary value and performance in addressable sensing technology, reduces nuisance alarms and makes service calls a rarity.

 

Packaging & Delivery

Packaging Detail:

carton

Delivery Detail:

depend on the order quantity

Fire Alarm Control Panel

 

Q: Fire alarm controller, fire alarm light, how do you need to do not light?
Then the host reset, if you can not eliminate false alarm, you can first block the alarm point, and then reset. Shielding points, please professionals deal with.
Q: Linkage relationship between automatic fire alarm system and fire sprinkler system
Automatic fire alarm system1. site by the smoke detector, temperature detector, UV flame detector, manual alarm button and fire display panel, light buzzer and other components; the control room by the fire alarm controller, CRT graphics display system.2. initial fire detector of fire (such as smoke, temperature) parameters timely response, automatic fire alarm signal; manual alarm button usually installed on the stairs and corridors, when the field staff discovered the fire, through the manual alarm button near, people can produce a fire alarm signal3. fire display panel is usually installed in the elevator room or desk, when the fire alarm controller receives the fire alarm, the alarm signal is transmitted to the fire in the fire area on the display panel, the display panel displays the fire detector and alarm reminder letter number Chinese characters information, also issued a "fire" sound signal. To inform the personnel of the fire region.4.GST5000 fire alarm controller monitors the working status of the detector, manual alarm button and other devices in real time, receives, displays and delivers the fire alarm signals, and gives control instructions when necessary.5. acousto-optic buzzer is usually installed in the corridors, stairs, when the fire occurred, the sound and light signal light buzzer send different from the environment, to remind the field staff of a fire.6.CRT graphic display system with similar electronic map display system with CRT graphics, can be more intuitive to determine the location of the fire, the fire for early confirmation.
Q: What is the difference between automatic fire alarm system, alarm controller and system linkage controller and system detector?
To buy an electric fire, that's allThe detector you're talking about is a sense of smoke and warmthAutomatic fire alarm system, alarm controller, this is the fire master, the host has linkage, there is no linkage, that is, when the fire started automatically fire equipment, such as water pumps and so on
Q: How to determine the total number of fire control alarm and the total number of points?
This is not just head out, but according to the construction design drawings, in accordance with the norms of building fire protection design, first calculate the number of all alarm detectors, linkage module, fire doors, acousto-optic alarm, manual alarm button and other equipment, and preliminary planning connection wiring, divided after loop according to the wiring length, loop load number the situation (when necessary, modify the wiring planning) and finally to determine total points and loop distribution, and to determine the fire alarm controller specification and tender.
Q: How does the fire alarm turn on and off?
The selection of the core section of transmission line of automatic fire alarm system should meet the requirement of technical condition of automatic alarm device, and also meet the requirement of mechanical strength. Minimum sectional area of copper core insulated conductor and copper core cable core.
Q: What is the function of fire alarm controller, public fire alarm and fault passive contact output?
The correct operation of the automatic monitoring system and the sound and light alarm for a specific fault.
Q: Fire linkage how to control the strong switch?
When the alarm system alarm, the linkage alarm host through a signal line to multi input / output module issued a directive, and 24V power line to start with the current action module, then the module into action, sending current to the relay, power switch for completion. At the same time, the module feedback the signal that has already been operated by itself through the signal line to the fire engine.
Q: Does the power control cabinet in the fire fighting system refer to the distribution box?
The distribution box has a wide range of meanings. It is divided into lighting distribution box, nonstandard distribution box and power distribution box. Among them, power control cabinet refers to the floor type, with two control of the distribution box, referred to as power distribution cabinet
Q: How to connect the elevator landing?
Wiring method for controlling module of elevator forced landing system by Lida module:The 1. module leads to the 2 line of the control cabinet, and receives two signals on the fire escape signal, the elevator brand is different, and the terminals are different.2. control cabinet output two lines, to the fire module, usually by elevator, fire linkage relay control, when there is fire signal, two lines on the pass.
Q: The difference between multi line fire control and bus control
That is, the device is connected in parallel to one of the buses. Using bus system, wiring is relatively simple. Under normal circumstances, if the number of fire linkage facilities is relatively large and centralized, the bus system is more economical and reasonable.
CFXFIRE, i products sell well in Europe, North and South America, Africa and the Middle East and Southeast Asia with it's good price and good service

1. Manufacturer Overview

Location Fujian, China
Year Established 2008
Annual Output Value Above US$ 1 Million
Main Markets North and South America, Africa and the Middle East and Southeast Asia
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a) Trade Capacity
Nearest Port Shengzhen
Export Percentage 40%
No.of Employees in Trade Department 200 People
Language Spoken: English; Chinese; Spain; Alabic
b) Factory Information
Factory Size: Above 60,000 square meters
No. of Production Lines 4
Contract Manufacturing OEM Service Offered; Design Service Offered
Product Price Range Average

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products


Hot Searches

Related keywords