Quick Details of Fire Alarm Control Panel
Place of Origin: | China (Mainland) | ||
Primary Power Supply: | 120V or 220VAC 50/60Hz | Standby Batteries: | DC24V 4AH sealed rechargeable batteries |
Display: | 15 lines x 40 characters LCD | Devices per loop: | 192 sensors & modules |
Specifications of Fire Alarm Control Panel
Addressable Fire Alarm Control Panel
Primary Power Supply: 120V or 220VAC 50/60Hz
Standby Batteries: DC24V 4AH seale
Addressable Fire Alarm Control Panel
Specifications
The powerful OZH4800E addressable fire alarm panel contains 2, 4, 6 or 8 SLC loops with each loop supporting 192 devices.
Primary Power Supply: 120V or 220VAC 50/60Hz
Standby Batteries: DC24V 4AH sealed rechargeable batteries
Power Supply Output: 24VDC @ 5.0 Amps (4 Amps available for system power)
Display: 15 lines x 40 characters LCD (600 characters total)
SLC loops: 2, 4, 6 or 8 (class A, "style 6 or 7" or class B, "style 4")
Devices per loop: 192 sensors & modules
Addresses per panel: 1536 max.
Communication Port: RS232/RS485
Operation Temperature: 10°C~+50°C Related Humidity: ≤95% (40±2°C)
Dimensions (D * W * H): 110×335×435mm
Weight: 16Kg.
Applictations of Fire Alarm Control Panel
The OZH4800E control panel is an analog addressable fire alarm panel using the latest 32 bit microprocessor technology and containing 2, 4, 6 or 8 SLC loops with each loop supporting 192 devices of any combination (sensors or modules). Communication between devices is transferred through standard cable (shielded or twisted pair is not required). Each panel includes a 5.0 amp power supply, 600 characters LCD display, 29 large easy-to-use tactile touchpad for system operation, programming and maintenance, 12 state indicators and a RS232/RS485 communication port. System operations include silencing alarms and troubles, resetting system and manual starting/stopping field equipment. The system's non-volatile event history buffer stores 9999 events for viewing. The system supports a variety of Orena devices: smoke and heat sensors, manual call points, contact input (monitor) modules, relay output modules, dual input/output modules, and short circuit isolator modules. In addition, interfaces to conventional detection systems can be established by using a conventional zone-monitoring module. The basic system can be expanded by adding OZF-LCD remote annunciator, OZH48ZL signalling line circuit expander, and optional mini-printer (for printing system reports). The intelligent panel and detectors know the difference between a fire and a dirty sensor. It lets you tailor sensor sensitivity and gives you immediate, pinpoint accuracy for any condition. The powerful OZH4800E system provides you with revolutionary value and performance in addressable sensing technology, reduces nuisance alarms and makes service calls a rarity.
Packaging & Delivery
Packaging Detail: | carton |
Delivery Detail: | depend on the order quantity |
- Q: Is there a standard for fire control room personnel in the new fire law?
- The working hours of each shift should be no more than 8h. There should be no less than 2 personnel per shift. The personnel on duty of the fire alarm controller for inspection, succession, shift, should fill in the "fire control room records related content of the table". During the shift, every 2h records fire control, indoor fire equipment operation, and timely records fire control, indoor fire equipment fire or failure.
- Q: Difference between fire alarm controller and fire alarm linkage control cabinet
- The fire alarm controller is mainly the alarm host, which displays the alarm information while detecting the fire.Fire alarm linkage control cabinet is mainly equipped with the switch of equipment that needs to be linked, such as fire fan start and stop button, air conditioning start and stop button, fire pump, spray pump, start stop button, and so on, as well as manual and automatic change-over switch.Now the design of the controller and alarm linkage control cabinet are combined together, some linkage equipment, such as air conditioning fan, fire damper and fire pumps are set by the host module automatic linkage alarm, only some specific equipment such as fire pump, an important local rain valve in case of need also must be set manually starting device.
- Q: Where should the fire control room power supply be used? Is it necessary to enter the line separately?
- Fire control room is usually double power supply, respectively, leading to different distribution rooms, is independent
- Q: The regional fire alarm controller will alarm. Will the adjacent fire zone call the police?
- Centralized fire alarm controller:Fire alarm controller with receiving information of each region type alarm controller. The centralized fire alarm controller can receive the information from the regional fire alarm controller or fire detector, and can also send certain control signals to make the regional fire alarm controller work. The centralized fire alarm controller has large capacity and can form a large automatic fire alarm system. It can also form a large fire alarm system with the regional fire alarm controller. Centralized fire alarm controller is usually installed in fire control room.
- Q: What are the components of a fire alarm system?
- In the automatic fire alarm system, when the fire alarm is received, the equipment that can automatically or manually fire the relevant fire equipment and display its status is called fire control equipment. Include fire alarm controller, automatic fire extinguishing system control device, control device of fire hydrant system, control device of smoke exhaust system and air conditioning ventilation system, normally open fire doors, fire shutter control device, lift down control equipment, and fire emergency radio, fire alarm, fire fighting equipment, fire emergency communication evacuation signs and lighting control device control device in whole or in part. Fire control equipment is generally installed in the fire control center, so as to facilitate centralized and unified control. Some fire control equipment is set up on the scene where the fire fighting equipment is located, but the operation signal must be returned to the fire control room, and a centralized and decentralized control mode is adopted.
- Q: What are the main parts of fire shutter?
- Fire shutter is mainly used in the fire protection division part of all kinds of industrial and civil and public buildings, public places such as factories, industrial plants, warehouses, supermarkets, materials market, shopping center, gymnasium, business center, hospital, air defense project, underground garage, Gaestgiveriet Hotel, school, port, station, Airport and other large area construction personnel more intensive.
- Q: What are the basic functions of fire alarm control?
- Fire alarm controller should be provided with a timing device for display or recording the fire alarm time, the timing error is less than 30s; only use the printer recording the fire alarm time, should print monthly, date and time, grading information.
- Q: Ask fire, weak water pump, control cabinet need how to put the line, what line should be put, the use of the line, the equipment is SIEMENS, specific points, such as online master pointing
- Fire pump has the following related weak wire: 1, roof fire water tank, flow switch with the NHKVV-2X1.5-SC20 control line, received fire hydrant, water pump control cabinet. 2, hydrant, water pump outlet pipe pressure switch with the control line (ibid.), received fire hydrant water pump control cabinet (spray pressure switch is located in wet alarm valve).
- Q: The difference between multi line fire control and bus control
- Multi line control of fire linkage is one to one, point to point control loop. Multi line control is controlled by the main control room for manual control! Usually not controlled by alarm systems, controlled by humans! (using relay, contactor)
- Q: Operation principle of fire alarm system input / output module
- Automatic fire alarm system (Fire Alarm System, referred to as FAS system) for early detection of people informed of the fire, and promptly take effective measures to control and extinguish the fire, an automatic fire facilities and set in a building or in other places, people are the same as a powerful tool to fight the fire.
1. Manufacturer Overview
Location | Fujian, China |
Year Established | 2008 |
Annual Output Value | Above US$ 1 Million |
Main Markets | North and South America, Africa and the Middle East and Southeast Asia |
Company Certifications |
2. Manufacturer Certificates
a) Certification Name | |
Range | |
Reference | |
Validity Period |
3. Manufacturer Capability
a) Trade Capacity | |
Nearest Port | Shengzhen |
Export Percentage | 40% |
No.of Employees in Trade Department | 200 People |
Language Spoken: | English; Chinese; Spain; Alabic |
b) Factory Information | |
Factory Size: | Above 60,000 square meters |
No. of Production Lines | 4 |
Contract Manufacturing | OEM Service Offered; Design Service Offered |
Product Price Range | Average |