Quick Details of Fire Alarm Control Panel
Place of Origin: | China (Mainland) | ||
Primary Power Supply: | 120V or 220VAC 50/60Hz | Standby Batteries: | DC24V 4AH sealed rechargeable batteries |
Display: | 15 lines x 40 characters LCD | Devices per loop: | 192 sensors & modules |
Specifications of Fire Alarm Control Panel
Addressable Fire Alarm Control Panel
Primary Power Supply: 120V or 220VAC 50/60Hz
Standby Batteries: DC24V 4AH seale
Addressable Fire Alarm Control Panel
Specifications
The powerful OZH4800E addressable fire alarm panel contains 2, 4, 6 or 8 SLC loops with each loop supporting 192 devices.
Primary Power Supply: 120V or 220VAC 50/60Hz
Standby Batteries: DC24V 4AH sealed rechargeable batteries
Power Supply Output: 24VDC @ 5.0 Amps (4 Amps available for system power)
Display: 15 lines x 40 characters LCD (600 characters total)
SLC loops: 2, 4, 6 or 8 (class A, "style 6 or 7" or class B, "style 4")
Devices per loop: 192 sensors & modules
Addresses per panel: 1536 max.
Communication Port: RS232/RS485
Operation Temperature: 10°C~+50°C Related Humidity: ≤95% (40±2°C)
Dimensions (D * W * H): 110×335×435mm
Weight: 16Kg.
Applictations of Fire Alarm Control Panel
The OZH4800E control panel is an analog addressable fire alarm panel using the latest 32 bit microprocessor technology and containing 2, 4, 6 or 8 SLC loops with each loop supporting 192 devices of any combination (sensors or modules). Communication between devices is transferred through standard cable (shielded or twisted pair is not required). Each panel includes a 5.0 amp power supply, 600 characters LCD display, 29 large easy-to-use tactile touchpad for system operation, programming and maintenance, 12 state indicators and a RS232/RS485 communication port. System operations include silencing alarms and troubles, resetting system and manual starting/stopping field equipment. The system's non-volatile event history buffer stores 9999 events for viewing. The system supports a variety of Orena devices: smoke and heat sensors, manual call points, contact input (monitor) modules, relay output modules, dual input/output modules, and short circuit isolator modules. In addition, interfaces to conventional detection systems can be established by using a conventional zone-monitoring module. The basic system can be expanded by adding OZF-LCD remote annunciator, OZH48ZL signalling line circuit expander, and optional mini-printer (for printing system reports). The intelligent panel and detectors know the difference between a fire and a dirty sensor. It lets you tailor sensor sensitivity and gives you immediate, pinpoint accuracy for any condition. The powerful OZH4800E system provides you with revolutionary value and performance in addressable sensing technology, reduces nuisance alarms and makes service calls a rarity.
Packaging & Delivery
Packaging Detail: | carton |
Delivery Detail: | depend on the order quantity |
- Q: Can the complex be equipped with two fire control rooms?
- When there are two or more fire control rooms, a master fire control room shall be determined.
- Q: How does the fire alarm turn on and off?
- Fire control, communication and alarm circuit with dark laying, should use the metal tube or plastic tube to protect the flame retardant treatment, and should be laid in the structure layer burning body, and the protective layer thickness of not less than 30mm. When used for laying, metal or metal groove shall be used for protection, and fire protection measures shall be adopted on metal tubes or metal wire grooves.
- Q: What does "fire line" on the fire alarm display mean?
- Multi line is probably said that a number of communications bus, or a number of communications lines, and now seems to fire only the linkage disk, multi line.
- Q: There are several fire control rooms in one building
- Fire control room in a building, usually 1Fire control room is equipped with automatic fire alarm control equipment and fire control equipment for receiving, showing, dealing with fire alarm signals, and controlling the relevant fire fighting facilities. Fire control room should be set up in the object of fire automatic alarm system with fire linkage function.
- Q: What is a fire bus control module?
- In view of the high reliability of fire fighting equipment and the prevention of automatic trouble, the manual direct control device shall also be set up in the fire control room. The method is through line control directly.
- Q: Does fire control line need to be connected directly to the control room?
- The direct control line has to go to the control room alone.
- Q: What is the loop card of the fire alarm controller?
- Single circuit board, each loop contains 242 address coding points, that is, the maximum can bring 242 peripherals.
- Q: How to choose the type of fire alarm controller?
- Well, generally speaking, the model for choosing fire alarm controllers has several processes.First, choose the fire alarm controller brand (according to the well-known level of choice, it is recommended to choose well-known brands such as the Gulf)Two, according to whether the local office, as well as the nearest after-sales service address to chooseThree select the specific model according to the number of your manual disk and bus disk and the number of fire alarm pointsFour, according to the size of your fire control center to choose, hanging or carrying.
- Q: Wiring principle of all kinds of fire fighting linkage control equipment
- The basic principle is open circuit control. That is, different control signals are output according to different input signals.
- Q: What does the centralized alarm system in fire control mean? And what do you mean by controlling the alarm?
- The control center alarm system generally applies to objects of protection of buildings or in large volume, may set up several fire control room to protect these objects, also may be due to the fire and the installment construction of the products of different enterprises or in the same enterprise in different series of products or systems due to capacity constraints and set up multiple has focused on the role of alarm controller so, these cases should choose the control center alarm system.
1. Manufacturer Overview
Location | Fujian, China |
Year Established | 2008 |
Annual Output Value | Above US$ 1 Million |
Main Markets | North and South America, Africa and the Middle East and Southeast Asia |
Company Certifications |
2. Manufacturer Certificates
a) Certification Name | |
Range | |
Reference | |
Validity Period |
3. Manufacturer Capability
a) Trade Capacity | |
Nearest Port | Shengzhen |
Export Percentage | 40% |
No.of Employees in Trade Department | 200 People |
Language Spoken: | English; Chinese; Spain; Alabic |
b) Factory Information | |
Factory Size: | Above 60,000 square meters |
No. of Production Lines | 4 |
Contract Manufacturing | OEM Service Offered; Design Service Offered |
Product Price Range | Average |
Send your message to us
Fire Alarm Control Panel
- Loading Port:
- China Main Port
- Payment Terms:
- TT or LC
- Min Order Qty:
- 100pcs m.t.
- Supply Capability:
- 10000 pcs per month m.t./month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot Searches
Related keywords