Features:
1.Standard cabinet design
2.High reliability: Average time between failures(MTBF)is 2 years at least
3.Long life time: Normal lifespan should be more than 8 years
4.Energy saving: 51% energy saving, lowering operation cost significantly
5.Dot by dot calibration: With Unilumin's pioneering calibration system, LED display keeps stunning image even after years's using
6.Easy to install: Stacking installation design enables easier installation
Parameter | Value |
Pixel Pitch | 6mm |
Pixel configuration | 1R1G1B |
LED type | 3-in-1 SMD3528 |
Brightness | 800 cd/㎡ |
Color temperature | 6500K |
Viewing angle | H: 120°; V:100° |
Physical density | 27778 pixels/㎡ |
Recommended viewing distance | 6 M |
Module size | 192mm×192mm |
Cabinet size | W768m×H768mm×D120mm |
Weight | 22 kg |
Area | 0.590 ㎡ |
Material | Epoxy Paint Coated Iro |
Aspect ratio | 1:1 |
Ingress protection | IP30 |
Operating Temperature/Humidity | 0℃~+45℃/10~90%RH |
Storage Temperature/Humidity | -10℃~+55℃/10~90%RH |
Pixels per panel | 128×128 Dots |
Processing depth | 12bits |
Gray scale | 4096 levels per color |
Color | 0.687 trillion(SUM2017)/281.4 trillion(SUM2030) |
Brightness control | Manual/Automatic |
Contrast ratio | 4000:1 |
Video frame rate | 50/60 Hz |
Rate refresh | ≥1000Hz(SUM2017)/ ≥3200Hz(SUM2030) |
Input voltage | 110~240VAC |
Input power frequency | 50~60Hz |
Input power <max> | 480W |
Input power <typical> | 160W |
Life Time | ≥100,000 Hours |
LED Wavelength | R:620~630nm G:520~535nm B:465~475nm |
Driving Method | 1/16 Scan, Constant Current |
Input signal | RF,S-VIDEO,RGBHV,YUV,YC & COMPOSITION,etc |
Rigging form | Fixed |
Data interconnection | CAT5 Cable)( L≤140m);Multi-mode fiber) ( L≤500m); Single mode fiber) ( L≤20km ) |
- Q:LED display more than the size of the area must be 380v
- LED display itself only need low-voltage DC power supply, whether it is 380V or 220V need to go through the buck and rectifier, which is the screen does not matter. Whether it is to use 380V or 220V depends entirely on the load balance of the power grid considerations, which depends not only on the size of the display, but also on the local grid capacity. In general, LED is weak devices, even if the display area and then large, the total power is also less than where to go, so you can use 220V single-phase power supply, but the power supply cable cross-sectional area to be larger, but the power circuit Much simpler.
- Q:Production of LED display the basic raw materials which ah?
- LED display (LED panel): LED is light emitting diode, LED abbreviation, referred to as LED. It is a kind of control by the semiconductor light-emitting diode display, the approximate look is by a lot of usually red light-emitting diodes, light off the light to show the characters. Used to display text, graphics, images, animation, market, video, video signals and other information display screen.
- Q:Comparison between LED display and DLP splicing
- DLP is a digital light processing, this technology is the first image signal through digital processing, and then the light projection. From DLP's technical principle, it has the least signal noise, accurate gray level, high reflectivity, seamless image display, high reliability and other advantages. DLP splicing screen by a number of rear projection display unit stitching, the most important feature is the patchwork small, you can control to 0.5 mm or less, we call it "seamless" splicing, which is the other two major technology LCD and PDP Can not and can not.
- Q:LED display a board dark light how is it?
- Visual power cable, unit board between the 26P cable and power module indicator light is normal. The following are the same as the "
- Q:16: 9LED What is the approximate size of the display?
- 16: 9 is only a proportional form, the specific size to be determined according to the area of the display. You display 16 meters long, 9 meters high, is 16: 9 ratio; display length of 10 meters, 5.6 meters high, is also the ratio of 16: 9. So there is no specific size!
- Q:Led display speed how to tune
- When installing the LED bar screen software, enter the text that needs to be displayed in the blue edit box. After the text editing is finished, click "Frame Properties" to pop up the following dialog box to set the frame properties. Display speed 1 fastest, 16 slowest. After setting the current frame, you can point to "previous frame" or "next frame" to move to another frame. After all the parameters of the frame are set, click the "Exit" button to return to the main window.
- Q:Ask to tell, or what decoder, mkv format can only put one, the rest of the mkv can not put any meaning?
- LED display is also flexible, you can achieve: with a TV screen overlay text information, panoramic, close-up, slow motion, effects and other effects of real-time editing and playback (need to configure another non-linear editing equipment) Window display different screen and text functions ? to meet the requirements of the use of theatrical performances ? graphic effects display function:
- Q:LED display power supply how to configure how many units with the plate is calculated.
- Upstairs are said that the P10, if you do not use the P10 it I tell you how to calculate the power of a board. Generally you take a lamp beads 0.02A to count, a board on the total lamp beads * 0.02, if the board is 4 sweep with the band / 4,8 sweep of the 8, the static is not removed to get a board of power
- Q:What is the difference between an LED display and an LCD monitor?
- LCD LCD liquid crystal display LCD full name, mainly TFT, UFB, TFD, STN and other types of liquid crystal display.
- Q:Is the TV screen good for the LCD or the LCD?
- In contrast, LED can easily do the regional regulation (which can be a certain degree of LCD light leakage problems, but can only be mitigated, theoretically almost impossible to achieve the traditional CRT CRT TV contrast), and life Longer (CCFL tube work for a few years there will be a decline in brightness or start the difficult phenomenon, need to be replaced.
1. Manufacturer Overview |
|
---|---|
Location | |
Year Established | |
Annual Output Value | |
Main Markets | |
Company Certifications |
2. Manufacturer Certificates |
|
---|---|
a) Certification Name | |
Range | |
Reference | |
Validity Period |
3. Manufacturer Capability |
|
---|---|
a)Trade Capacity | |
Nearest Port | |
Export Percentage | |
No.of Employees in Trade Department | |
Language Spoken: | |
b)Factory Information | |
Factory Size: | |
No. of Production Lines | |
Contract Manufacturing | |
Product Price Range |
Send your message to us
F6-i Indoor Fixed LED display LED Display High Pixel Density
- Loading Port:
- China main port
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 10 m²
- Supply Capability:
- 10000 m²/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches
Related keywords