• Excavator digging bucket CE certification made in China System 1
  • Excavator digging bucket CE certification made in China System 2
Excavator digging bucket CE certification made in China

Excavator digging bucket CE certification made in China

Ref Price:
get latest price
Loading Port:
Shanghai
Payment Terms:
TT OR LC
Min Order Qty:
1 pc
Supply Capability:
2000 pc/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

Excavator digging bucket CE certification made in China

Basic Info

Model NO.:VXD-200

 

Type:Crawler Excavator

Usage:GM Excavator

 

Transmission:Hydraulic Transmission

Drive Type:Cylinder

 

Bucket Capacity:1.0~1.5m³

Size:Large-Scale

 

Certification:CE, ISO9001: 2000, SGS

Condition:New

 

Capacity:0.5m3

Teeth Plate Thickness:25mm

 

Side Plate Thickness:20mm

Top Width:1908mm

 

Bottom Width:300mm

Bucket Height:1400mm

 

Bucket Weight:780kg

Material:Q345b

 

Warranty:6month

Export Markets:Global

Additional Info

Trademark:GD-Haide

 

Packing:Bubble Film

Standard:SGS, CE, ISO9001: 2000

 

Origin:Dongguan City, Guangdong Province, China

HS Code:843149

 

Production Capacity:1000set/Year

Product Description

Excavator trapezoid bucket

Capacity: 0.5m3
Teeth plate thickness: 25mm
Side plate thickness: 20mm
Top width: 1908mm
Bottom width: 300mm
Bucket height: 1400mm
Bucket weight: 780kg
Material: Q345B
Warranty: 6month

You can choose the material as your demand to choose NM400 or HARDOX400. 
According to different construction environment and customer requirement, we rationally deal with stresses, select high quality steel, use perfect welding to guarantee the structural strength, performance and quality. 

We also can manufacture it as per your any requirements. We can make it 0.1m3 up to 12m3.

Capacity(m3)MaterialOpening length(mm)width(mm)deepth(mm)teeth plate thickness(mm)Side plate thickness(mm)Gusset plate thickness(mm)
0.4 Q345B87064056025206
0.6 Q345B98084064030208
0.8 Q345B11201040750403010
1.0 Q345B11801140780403010
1.3 Q345B13001260820403012
1.5 Q345B13001340900504012
2.0 Q345B140015401020504016
2.5 Q345B145016601100504016
3.0 Q345B150017801200504016
3.6 Q345B160018401300504016

Excavator digging bucket CE certification made in China

Excavator digging bucket CE certification made in China


Q:How do they ventilate subway tunnels when they are building them? Obviously they cant use just electric vehicles to create stations and tunnels. TBMs are electric but they must use excavators, loaders, etc when building stations beneath the surface. How do they ventilate these tunnels?
There are several methods that have and are employed to make tunnels.1 Why do you feel it is obvious that electric machines cannot be used? Tunnels are the type of spaces with limited air that are ideal for the use of non polluting vehicles. Rather than say We have to make pollution, how can we move it somewhere else engineers have asked, How can we not pollute the air. Subways are electrically powered. Modern tunneling machines are probably the very largest electric vehicles.2 Some of the machines have their own power stations located outside of the tunnels and some of the machines will use a grid connection. In most pictures of tunneling you will notice either a conveyor belt or a railroad removing debris.Both of these are also easily electrified. Formerly shafts were sometimes run to the surface for removing debris. And this may continue to be a solution for ongoing operations. There is an island in the middle of the East River in NYC outside of the UN that was formed from tunneling debris for the #7 subway line.3
Q:Bench tested altinator,it's good,new batteries,new belts,checked fuses, still only 24.8 volts at the batteries.Should be around 28 volts with engine running. Display in opperators cab reads quot;charging problemquot;. Is there a relay I don't know about?
yes yu may have an external regulator fitted , some times its under the seat , maye be elsewhere , might be near fuse box , should be bigger than a normal relay , will have alt written on it , probably black and plastic , yu can try and call dealer parts section and ask them if there's one on yur machine , yu will need serial number of coz , if its imported serial number wont be any good , is the charge indicator light on the control panel working , did yu check the fuses ?........ move them around in case there's a corroded connection , how many wires on back of alternator ?.......should be big red one , and at least one small one ( signal wire ) make sure this is ok , make sure wiring harness from engine to chassis is ok , yu might find wiring diagramm on internet , this will show external reg , are there any small wires connected to the big ht ( high tension ) wire on the battery ?.......is there an inline fuse fitted there ?? .....is corrosion a problem with any part of the harness ? dont be afraid to cut open the harness with a box cutter knife if yu think yu have a problem , its ok it wont bleed , just retape back together in a proffesional manner when checked out ,
Q:I graduated high-school in 09 and started college for a welding degree I dropped out got a job as a entry level welder now I want to go back to school but not for welding I'm good at it but its not what I want to do forever my I love being outdoors what would be a well paying career choice p.s. I don't think gamewarden would be a something I'm interested in or any other government job...
Forestry service, Arborist, Farmhand, Cell phone tower repair/installer, surveyor, water tester, excavator.
Q:What is the average price of a small inground swimming pool (50-80 ft. perimeter)?
there are many shapes to choose from, rectangle, oval, kidney, etc. so it varies slightly for shapes but for that size generally it is gonna run anywhere from 5 grand up to 7 grand
Q:Can I use excavator substrate for my leopard gecko?
Any type of loose substrate for a leopard gecko runs the risk of impaction, I would not recommend it for the safety of your gecko. Reptile carpet once full grown or paper towels or tile can be used.
Q:I have a few questions about breeding Leos. And please don't answer anything like quot;Lol you shouldn't be breeding themquot; or stuff like that. I will down vote any of that stuff, and please no guesses either. I want answers from people with actual experience. So my first question is, how many eggs in a season do they lay?
How To Breed Leopard Geckos
Q:Where is the throttle motor for the excavator?
There's a stupid way to help you. You can find it along the throttle line of the engine
Q:Arctic dumper drivers etc
Yep, there's a demand and it's big. If you're really good. Heavy equipment operators are always in demand almost everywhere in Canada, but only the operators who are extremely good. You have to have a solid record of getting every job done on time, no exceptions and no excuses. If you've got that, you're in demand.
Q:We are working on a project up North (Nunavut, Cit anada) and there is 45,000 Gallon of JP-4 left there by the USAF in the mid-80's (probably when they turned to JP-8). That's a large volume we would preferably reused than shipped and disposed at high cost in the south. If possible, we are looking forward to mix the JP-4 with additives and use it in the heavy equipment (excavators, trucks, loaders, etc). Some info gathered on the internet mentionned to mix JP-4 with 10W30 motor oil, but we need a precise answer as we cannot afford to damage the diesel engine of the equipment. Thanks a lot for your help !
With this much fuel, some processing is required. This could be as simple as prefiltering prior to use. In order to not harm your engines, you will need to raise the flashpoint of the JP4.(FP = 0F). Petro diesel has a flashpoint of ~180F. Mixing it with waste oil is a good idea, but proportioning will be an issue. You will need to have both the JP4 and the Oil you intend to yse tested in a local lab. You need to know the following 1. pour point 2. viscosity 3. flashpoint. then Prepare a decade series of mixtures with increasing amounts of oil 1% oil, 10% oil, 20% and so on. plot the flash points for this series and determine the exaact mixture that gives you 182 degrees F. If your JP4 is in barrels the mixing is easier. If its in a tank farm there will be more processing. You will have to deal with algae, water and a lot of sediment. good luck
Q:How do you calculate the amount of backhoe?
According to the drawing and calculation rules, the working surface and the slope are calculated. The type of excavator is not related, but the coefficient of slope is different between the pit operation and the down hole operation. If the coefficient of operation under the pit is small, the earthwork of the downward slope of the excavator should be calculated

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

Hot products


Hot Searches

Related keywords