• Ductile Iron  Valves DN100 System 1
  • Ductile Iron  Valves DN100 System 2
Ductile Iron  Valves DN100

Ductile Iron Valves DN100

Ref Price:
get latest price
Loading Port:
China main port
Payment Terms:
TT OR LC
Min Order Qty:
100 PCS
Supply Capability:
1000 PCS/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

1.Structure of Gate Valve Description:

 

A gate valve, also known as a sluice valve, is a valve that opens by lifting a round or rectangular gate/wedge out of the path of the fluid. The distinct feature of a gate valve is the sealing surfaces between the gate and seats are planar, so gate valves are often used when a straight-line flow of fluid and minimum restriction is desired. The gate faces can form a wedge shape or they can be parallel. Gate valves are primarily used to permit or prevent the flow of liquids, but typical gate valves shouldn't be used for regulating flow, unless they are specifically designed for that purpose. Because of their ability to cut through liquids, gate valves are often used in the petroleum industry. For extremely thick fluids, a specialty valve often known as a knife valve is used to cut through the liquid. On opening the gate valve, the flow path is enlarged in a highly nonlinear manner with respect to percent of opening. This means that flow rate does not change evenly with stem travel. Also, a partially open gate disk tends to vibrate from the fluid flow. Most of the flow change occurs near shutoff with a relatively high fluid velocity causing disk and seat wear and eventual leakage if used to regulate flow. Typical gate valves are designed to be fully opened or closed.When fully open, the typical gate valve has no obstruction in the flow path, resulting in very low friction loss.

 

2. Main Features of the Gate Valve:

• Valve body cavity using non-toxic epoxy resin,both inside and outside flashboard completely is coated with rubber

•  Free of water pollution

• High manufacturing accuracy

• High strength

• Environmental protection and energy saving

• Good visual effect

3. Images

 

Ductile Iron  Valves DN100

Ductile Iron  Valves DN100

Ductile Iron  Valves DN100

4. Gate valve Specification

 Ductile Iron  Valves DN100

5.FAQ

1. What's are the characteristics of gate valve?

The distinct feature of a gate valve is the sealing surfaces between the gate and seats are planar, so gate valves are often used when a straight-line flow of fluid and minimum restriction is desired. The gate faces can form a wedge shape or they can be parallel. 

2. What is the work principle of gate valve ?

 The gate faces can form a wedge shape or they can be parallel. Gate valves are primarily used to permit or prevent the flow of liquids, but typical gate valves shouldn't be used for regulating flow, unless they are specifically designed for that purpose. Because of their ability to cut through liquids, gate valves are often used in the petroleum industry. 

3.  What is the structure?

Bonnets provide leakproof closure for the valve body. Gate valves may have a screw-in, union, or bolted bonnet. Screw-in bonnet is the simplest, offering a durable, pressure-tight seal. Union bonnet is suitable for applications requiring frequent inspection and cleaning. It also gives the body added strength. Bolted bonnet is used for larger valves and higher pressure applications.

Q: Soft sealed gate valve and hard sealing gate valve which good?
If the caliber, material and pressure levels are the same, the current market price is still soft sealed gate valve, about 20-30%.
Q: greater than DN50 of the pipeline butterfly valve?
It's not the valve! But the price relationship!
Q: What are the features and uses of the gate valve?
1) advantages: sealing performance than the cut-off valve, the fluid resistance is small, open and close more effort, full sealing surface by the erosion of media, media flows from the restrictions, with double flow, small structure length, wide application range. 2) disadvantages: high size, open need a certain space, opening and closing time is long, in the opening and closing, the sealing surface is easy to erode and scratch, and the two sealing pairs bring difficulties to the processing and maintenance.3) use: gate valve is generally used in the caliber of DN15-1800mm pipes and equipment, and its dosage is great, mainly cutting off function, not allowed to throttle.
Q: Z41T one 10 gate valve and Z44T one, 10 gate valve difference
Z41T one, 10 is single gate, Z44T one, 10 is double gateAccording to the provisions of the JB/T 308-2004 valve type programming method:Z== gate valve4== connection: flange type1== structure: Rigid single gate4== structure: Rigid double gateT== sealing surface material: copper alloy10== pressure rating: 1.0MPa
Q: Why? God, can you explain to me in detail why?
The exit of the general pump is the first soft connection (shock absorber), followed by the check valve, and then the partition valve (such as butterfly valve, gate valve, cut-off valve, etc.), this is not the final answer.The question is interesting, and no corresponding information has been found in the relevant standards. We have also discussed the related issues, but differences of opinion is relatively large, the advantages of 1, first installed check valve installed after the valve or butterfly valve, check valve, can be protected, especially in a parallel pump, when the pump does not start, another pump starts when the impact force is gate valve or butterfly valve bear, disadvantages: gate valve or check valve who will protect? There have been a case of butterfly valve is broken. 2, first installed gate valve or butterfly valve installed after the check valve, advantages: can protect the butterfly valve or gate valve, the impact on the check valve to bear. Disadvantages: check valve who will protect, check valve by pressure difference switch, if the high pressure high pressure pipe, pump, if the flow is not stable, so check valve will repeatedly switch, will affect the check valve life. Personal opinion: check valve, check valve performance now have changed, many are using the slow closing check valve, so the impact force is two aspects to bear, because exports are not fully open the valve or butterfly valve, so you can put in check after the gate valve or butterfly valve valve. If not the slow closing check valve installed in the valve or the best after the butterfly.
Q: What is the difference between cut-off valve and gate valve?
Simply put, the cut-off valve is one-way, only into, do not give up, the valve is two-way
Q: Why does the fire hydrant box in the air defense area need to be added with gate valves?
when the envelope from the introduction of civil air defense, air defense should be set in the side of retaining structure; through the protection unit between the closed wall, should be installed in the pipe walls on both sides of the door closed;2 protection valve nominal pressure shall not be less than 1.OMPa;
Q: What's the meaning of flexible z45x-10q door valve?
Crown valve pressModel Z45X-10QZ refers to gate valve4 finger flange connection5 refers to the dark bar driveX refers to rubber seals10 refers to 10 kg pressureQ refers to the body material, ductile ironFull bore flange soft sealed gate valve
Q: What is the gate valve for the DN65 hydrant?
DN150, of course. Ask me about fire protection
Q: What is the difference between the cut-off valve and the gate valve?
Selection of stop valve:There are two ways to install the valve, one is the media flow from the top of the spool, the advantage is that when the packing is not under pressure, the pressure can be replaced before the valve packing, there is a long service life characteristics. Another is the media from the bottom of the spool into, and its shortcomings are driving torque is large, is 1 times above the flow, the stem by the axial force of large, easy to bend the stem. Generally suitable for small caliber manual stop valve, to stop the valve closed, the media acting on the spool of force is not greater than 350kg limit. Electric cut-off valve is generally used to enter the media from the top way.Selection of gate valve and stop valve:Valve than the valve structure is simple, better sealing, manufacturing and maintenance to be convenient; shortcomings are fluid resistance, power, and opening and closing efforts. Gate valve, stop valve are fully open, fully closed valve, suitable for making cut off, it is not suitable for use as regulating valve. The application process should pay attention to the characteristics of the valve when selecting. Small pipes and better sealing performance generally use cut-off valve; in the steam system and large diameter pipeline, due to fluid resistance is small, suitable for use gate valve.