Ductile iron BS5163 gate valve
- Loading Port:
- China Main Port
- Payment Terms:
- TT OR LC
- Min Order Qty:
- -
- Supply Capability:
- -
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
Packaging & Delivery
Packaging Detail: | plywood case |
Delivery Detail: | 30days after recieve your deposit |
Specifications
1.Face to Face:BS5163
2.Material: Cast iron
3.Nominal Pressure: PN16
4.Stem Material:Stainless Steel
5.Flange End:2"-24''
Product Description
rising stem gate valve, metal seated gate valve
BS5163 gate valve
Cast iron gate valve
Rising stem gate valve,
Product name:
Rising stem gate valve
BS5163 gate valve
Cast iron gate valve
OS&Y gate valve
BS rising stem gate valve
BS gate valve
resilient seat gate valve
Material
Body: CI or DI
Disc: CI or DI
Seat: Brass/Bronze
Stem: stainless steel
Standard
Face to face: BS5163:1986,BS5150
Flange: BS 4504&BS10table E or D
Pressure
PN10/16
- Q: What are the advantages and disadvantages of flat gate valves?
- The advantage of flat gate valve is that the flow resistance is small, and the flow resistance is similar to the flow resistance of short valve. The flat gate valve with guide hole is installed on the pipeline and can be directly cleaned with the cleaner. As the gate is sliding on the two seat surface, the flat gate valve can be applied to the medium with suspended particles, and the sealing surface of the flat gate valve is actually positioned automatically. The seat seal surface is not subject to thermal deformation of the valve body. Moreover, even if the valve is closed in cold condition, the thermal elongation of the stem will not cause the seal to be subjected to overload. The length of the structure is much shorter than that of the ball valve, and it is easier to start. Light plate gate valve is more refined, but the effect is exactly the same.The disadvantage of flat gate valve is that when the medium pressure is low, the sealing force of the metal sealing surface is insufficient, so as to achieve satisfactory sealing. On the contrary, when the medium pressure is high, if the sealing surface is not lubricated by the system media or foreign media, often opening and closing may cause the sealing surface to wear too much. Another disadvantage is that the circular motion of the circular gate in the circular flow, only when it is at the valve closed position of 50%, this valve is more sensitive to flow control. Moreover, the gate will produce severe vibration when it breaks the high-speed and dense medium flow. The valve seat can also be throttled if the seat is made of a V - shaped opening and is tightly oriented to the gate.
- Q: What valve is z45w gate valve?
- Cast iron gate valve with turbine head, please contact me
- Q: Gate valve DN65 what does that mean?
- Caliber 65, refers to the size of the gate valve, you want to buy it?
- Q: How to distinguish between gate valve and cut-off valve?
- Standard light valve professionals to answer for you, gate valve refers to the closure of parts (gate) along the central line of the vertical direction of moving valve. The gate valve is mainly used for cutting in the pipeline. The valve is a valve with a very wide, cutting device general caliber DN = 50mm use it, sometimes a small diameter cutting device also use valve, gate valve has the following advantages:Fluid resistance is small.Minor force needed for opening and closing.Medium flow is unrestricted.When opening fully, the sealing surface is eroded by the working medium smaller than the cut-off valve.
- Q: Why? God, can you explain to me in detail why?
- The exit of the general pump is the first soft connection (shock absorber), followed by the check valve, and then the partition valve (such as butterfly valve, gate valve, cut-off valve, etc.), this is not the final answer.The question is interesting, and no corresponding information has been found in the relevant standards. We have also discussed the related issues, but differences of opinion is relatively large, the advantages of 1, first installed check valve installed after the valve or butterfly valve, check valve, can be protected, especially in a parallel pump, when the pump does not start, another pump starts when the impact force is gate valve or butterfly valve bear, disadvantages: gate valve or check valve who will protect? There have been a case of butterfly valve is broken. 2, first installed gate valve or butterfly valve installed after the check valve, advantages: can protect the butterfly valve or gate valve, the impact on the check valve to bear. Disadvantages: check valve who will protect, check valve by pressure difference switch, if the high pressure high pressure pipe, pump, if the flow is not stable, so check valve will repeatedly switch, will affect the check valve life. Personal opinion: check valve, check valve performance now have changed, many are using the slow closing check valve, so the impact force is two aspects to bear, because exports are not fully open the valve or butterfly valve, so you can put in check after the gate valve or butterfly valve valve. If not the slow closing check valve installed in the valve or the best after the butterfly.
- Q: Why the valve can only be fully open and fully closed valve can adjust the flow?
- You said the cut-off valve is that the spool is rotating rather than vertical movement structure?Theoretically, the flow regulation can be realized by controlling the position (angle or distance), and all of them have mature products.
- Q: Function of gate valve
- Gate valve is a closed (gate) along the central line of the vertical direction of the valve moving. Valve in the pipeline can only be fully open and fully closed off, can not be adjusted and the throttle. Gate valve is a valve used in a wide range, generally more than 50mm caliber DN block device is selected it, sometimes cut off very small aperture devices are used to gate valve, gate valve is used as cut-off media, when in full flow through the whole, when the media is running a minimal pressure loss. Gate valves are normally used in situations where they do not need to be frequently opened and closed, and the gate is fully open or fully closed. Not used as an adjustment or throttling. For high speed moving medium, the gate can cause the vibration of the gate under the condition of partial opening, and the vibration may damage the sealing surface of the gate and the valve seat, while throttling will cause the gate to suffer the erosion of medium.
- Q: What kind of valve is gate valve? Is it different from the cut-off valve?
- Gate valve is applied to the big diameter pipeline valve, the valve is generally used in small pipe diameter pipeline, their internal structure is different, the valve can not regulate the flow of water, the valve can be. If you want to understand in detail, it is recommended to take a sample of valve manufacturers to see the internal structure.
- Q: Gate valve is gate valve, gate valve specifications, model code is generally what?
- Valve lock valve and gate valve. According to the code, the domestic valve type standard, valve type valve is composed of valve type, drive mode, valve connection, valve structure, sealing material, body material code to said gate type code Z.Gate valve: gate valve is one of the most commonly used shut-off valve, mainly used to connect or cut off the pipeline medium, not used to regulate the flow of media. A wide range of pressure, temperature and diameter is used, especially for medium and large diameter pipes.1, the main characteristics of gate valve(1) fluid resistance is small. The through hole of the gate body is straight through, and the flow direction of the medium does not change when flowing through the medium, so the flow resistance is smaller.(2) opening and closing is more labor-saving. When opening and closing, the direction of valve plate movement is perpendicular to the direction of flow of medium. Compared with the opening and closing more effort.(3) medium flow direction is generally unrestricted. The medium can flow in any direction from both sides and can achieve the purpose of switching on or cutting off. Easy to install, used in the flow direction of the medium may change in the pipeline.
- Q: What are the standards for the execution of cast iron dark pole gate valves?
- Three, cast iron gate valve structure features:1.. The structure is simple and compact, the design is reasonable and novel, the rigidity of the valve is very good, the passage has a large flow area, the medium is unimpeded, and the resistance is small;2., the sealing surface of the material selected carbide and stainless steel, has a reliable sealing performance, long service life;3. cast iron dark rod gate valve using graphite material for packing, easy to operate;4., can use a variety of driving methods, such as manual, electric, pneumatic, gear drive, etc.;5., the position of the two sides of the gate valve is symmetrical, so the medium can flow freely on both sides, and the installation is very convenient;6. cast iron hidden rod gate valve structure length is short, the quoted manufacturing process is good, the scope of application is very wide;
Send your message to us
Ductile iron BS5163 gate valve
- Loading Port:
- China Main Port
- Payment Terms:
- TT OR LC
- Min Order Qty:
- -
- Supply Capability:
- -
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches
Related keywords