• CNBM Ductile iron BS5163 gate valve 12'' System 1
CNBM Ductile iron BS5163 gate valve 12''

CNBM Ductile iron BS5163 gate valve 12''

Ref Price:
get latest price
Loading Port:
China Main Port
Payment Terms:
TT OR LC
Min Order Qty:
-
Supply Capability:
-

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

Product Description:

1.standard: DIN/BS/ISO

2.port size: DN32-700mm

3.function:

   This pilot-operated pressure reducing valve is professionally used to resolve the domestic water and fire-fighting problems in high-rise buildings, and it can completely replace the water tank.

4.main material list:

body/cover

ductile iron/cast iron

tubes/pilot valve

ss/brass

stem/spring

ss

O-ring/gasket

NBR/EPDM

seat

brass

bolts/washer

ss

5. connection: flange  

6.PN 1.0/1.6 /2.5Mpa

7.coating: epoxy painting

8.adavantages:

A. strictly designed accordingto the cybernetics of hydraulic principles;

B.   working stablly and reliablly with big flow passage;

C.   valve clack opens quickly and close slowly without water hammer shock because of the adjustable closing time;

D.   with good sealability and long span,etc.

Company Information:

   Allwin Pipe Fittings Co.,Ltd is a private enterprise specialized in exporting various kinds of pipes, pipe fittings, couplings and adaptors, valves, man-hole covers and gratings, fire hydrants,and strainers,etc.(mainly ductile iron&cast iron)

   We can supply all above products with different standards and specifications.  Our products have been wdely exported to many places in the world, such as Europe, Southeast Asia, USA, Middle East, African countries, China Hongkong, and Taiwan,etc.

   We promise  that you can get the wanted products with best quality in the most competitive price and the most satisfied services.

Packing&Shipping:

packaging: standard wooden cases with bubble plastic bags for each item or as per your requirements

delivery detail: 25-30 days

Q: What do you mean by "2" and "200 CF8M"?
CF8M is stainless steel, and 2 is caliber 50200 and should also be bore
Q: Gate valve, butterfly valve, ball valve advantages and disadvantages? What are the usual valves?
Stop valve: a valve that closes the valve and moves along the center line of the valve seat. According to this form of valve movement, the valve seat opening change is proportional to the valve stroke. Because of the valve stem to open or close the trip is relatively short, but very reliable cut off function, and because changes in the valve seat and the valve stroke is proportional, is very suitable for flow regulation. Therefore, this type of valve is very cooperative for cutting or regulating and throttling.Advantages: in the process of opening and closing, because the friction between the valve and the sealing surface of the valve body is smaller than that of the gate valve, the utility model has the advantages of wear resistance. Second, the opening height is generally only 1/4 of the seat channel; therefore, it is much smaller than the gate valve; usually there is only one sealing surface on the valve body and the disc; therefore, the manufacturing process is better and the service is easy to maintain. Because its packing is generally a mixture of asbestos and graphite, it has a higher temperature resistance. Steam valves are normally used with stop valves.Disadvantages: as a result of the medium through the valve flow direction has changed, so the minimum flow resistance valve is higher than most other types of valves; second, due to longer travel, opening slower than the ball.
Q: What gate DH10016, AM
The first Z represents the gate valve (the initial consonant of the Chinese phonetic alphabet for the gate); the second 2 represents the drive mode of the valve, that is, electro hydraulic drive.
Q: What else, P54140V, 170V? What do they mean?
P work pressureP54 temperature at 540 degrees of work pressureThe pressure at P54 100 is 540 at the temperature of 100barV valve for chromium molybdenum vanadium steelP54 pressure 140V temperature at 540 DEG C for 140bar valve for chromium molybdenum vanadium steelP54 pressure 170V temperature at 540 DEG C for 170bar valve for chromium molybdenum vanadium steelFrom the JB/T4018 "valve type model preparation method"The standard unit is MPa, but it is usually used in bar
Q: Why does the fire hydrant box in the air defense area need to be added with gate valves?
3, protective valve should be used for stainless steel or copper gate valve or cut-off valve;4, air defense enclosure structure, the distance from the proximal end of the valve should not be greater than 200mm. Valve should have obvious signs of opening and closing.
Q: What kind of copper gate valve copper content standards, there are no national standards?
Usually copper alloy, rarely used pure copper, there are GB
Q: What is the difference between gate valve and gate valve? Is it the same valve?
Gate valve and gate valve are 2 kinds of valves, do not feel like a long name is the same kind, please look at Baidu maps introduced manufacturers.
Q: Which is the most expensive, check valve and gate valve?
In the case of DN50 Z15T-16 DN50: screw valve 46.200 thread copper bar gate valve Z15T-16 DN50 52 Z45F-16 DN50 97 flange valve flange valve rod Z44T-10 DN50 169 Z45T-116 DN50 flange valve dark bar 173 thread swing check valves DN50 52.090 thread straight type check valve DN50 57.280 flange screw check H44T DN50 129 flange valve lift check valve H41T-16 DN50 124
Q: The main question is, what are the functional differences in which case?
The gate (gate valve) is a gate opening and closing parts, RAM direction of motion perpendicular to the direction of the fluid, valve can only be fully open and fully closed, can not be adjusted and the throttle gate valve. The direction of motion perpendicular to the direction of the fluid, valve can only be fully open and fully closed, can not be adjusted and the throttle.Gate valve advantages: 1, fluid resistance is small,.2, opening and closing more labor-saving,.3, medium flow unrestricted, not disturbed flow, do not reduce pressure,.4, simple shape, structural length is short, manufacturing process is good, a wide range of applicationsValve shortcomings: 1, between the sealing surface is easy to cause erosion and abrasions, maintenance is more difficult,.2, big size, open need some space, opening and closing time is long,.3, the structure is more complex
Q: What is the difference between the cut-off valve and the gate valve?
Selection of stop valve:There are two ways to install the valve, one is the media flow from the top of the spool, the advantage is that when the packing is not under pressure, the pressure can be replaced before the valve packing, there is a long service life characteristics. Another is the media from the bottom of the spool into, and its shortcomings are driving torque is large, is 1 times above the flow, the stem by the axial force of large, easy to bend the stem. Generally suitable for small caliber manual stop valve, to stop the valve closed, the media acting on the spool of force is not greater than 350kg limit. Electric cut-off valve is generally used to enter the media from the top way.Selection of gate valve and stop valve:Valve than the valve structure is simple, better sealing, manufacturing and maintenance to be convenient; shortcomings are fluid resistance, power, and opening and closing efforts. Gate valve, stop valve are fully open, fully closed valve, suitable for making cut off, it is not suitable for use as regulating valve. The application process should pay attention to the characteristics of the valve when selecting. Small pipes and better sealing performance generally use cut-off valve; in the steam system and large diameter pipeline, due to fluid resistance is small, suitable for use gate valve.

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

Hot products


Hot Searches

Related keywords