Specifications

digital high pressure heat press machineAPD-20

1.factory wholesale OEM ODM

2.high pressure transfer machine

3.heat transfer p

Detailed Product Description

Pneumatic High Pressure Draw-out Heat Press APD-20 New Design is designed with automatic air operated pressing.

Specifications

Pneumatic High Pressure Draw-out Heat Press APD-20 New Design

Machine Type: Automatic

Platen Size: 16"*20"/16"*24"

(40*50cm/40*60cm)

Under Plate: Draw-out

Controller: GY-04 Digital Time & Temperature Control

Printable Articales: Up to 20mm Thickness

Air Compressor Required: Yes

Voltage: 120V/ 220V

Power: 2500W

Time Range: 0-480 sec.

Maximum Temp: 225 C

Temperature Accuracy: ±0.5%

Packing Size: 77*53*75cm

Gross Weight: 62kg(Wooden Package)

Q: Heat conduction oil furnace with coal or electricity?
Electricity more energy conservation and environmental protection
Q: What is the difference between diversion in heat exchanger heat exchanger and diversion?
In diversion tube heat exchanger is inside the shell side of heat exchanger tube set up within the guide tube make the before or after the end of the heat exchanger without diverting tube before use hard to make full use of the heat transfer of heat exchange tube, thereby increasing the effective heat transfer area of heat exchanger. Hypoxia or diversion tube used in fixed tube plate heat exchanger, and less common in the u-tube heat exchanger. Flow heat exchanger was increased on the shell side of heat exchanger in the original cylinder a zoom cone section presents to the diffusion of shell side fluid, and makes the fluid from the ends of the heat exchanger shell side into the shell side, avoiding the consider cloth tube in heat exchanger tube arch is high, and the increased number of cloth tube heat exchanger with norms and effective utilization of the heat exchanger before and after the heat exchange tube so as to increase the effective heat transfer area. Outside the diversion tube commonly used in the fixed tube plate heat exchanger, and in the u-tube heat exchanger and floating head heat exchanger is not common Diversion tube inside and outside the diversion tube flush function point of view is the same, all is in order to increase the effective heat transfer area of the heat exchanger. But tell from the purpose, the latter to the former than the latter in the fixed tube plate heat exchanger can increase the amount of cloth tube heat exchanger. As heat exchanger equipment can be seen everywhere, very popular in the industry, especially in energy consumption is very large areas, with the rapid development of energy-saving technology, heat exchanger type development more and more. Suitable for different medium. Different condition, different temperature and pressure of heat exchanger, the structure and pattern are also different.
Q: The working principle of new special viscous material scatter equipment?
Break up after the material fall into drying equipment inside the cylinder, the material in the drying drum under uniform of copy board flipping, evenly dispersed in contact with the hot air fully and achieve drying of heat and mass transfer.
Q: How hot is spread from one end of the metal strip to the other end of the
Mainly through the way of heat transfer, by metal molecular vibration energy transmission to the surrounding molecules to transfer heat
Q: The basic principle of heat exchanger is what?
: the basic principle of heat exchanger is made by high temperature heat fluid is passed to the lower temperature of fluid, the fluid temperature can reach the indexes of the flow rules, so as to meet the needs of process conditions, but also to improve energy utilization.
Q: Why heater before operation will be into the air in the device?
General way of heater is a heating medium for the required material heating, heat conduction oil heater, for example: air does not do, unstable pump pressure, the air blocking in the pipe, heat conduction oil can't circulation, quantity of heat cannot be passed on to the material.
Q: What are the causes of failure of plate heat exchanger?
Here's why: 1, the plate heat exchanger is material pressure fluctuations, or working temperature is too high; 2, gasket long-term use of cracks, aging; 3, plate produce permanent deformation, not fixed gasket; 4, the surface of the plate heat exchanger or channel with low thermal conductivity materials produce congestion; 5 of plate heat exchanger, plate heat exchanger fouling scale results in the decrease of the heat transfer coefficient of heat transfer equipment
Q: What is the working principle of heat pipe
Typical gravity heat pipe, as shown in the airtight tube first into a vacuum, filling the appropriate working medium under this state, on the lower end of the heat pipe heating, laser vaporization heat absorption for steam, under the small pressure difference, up to the upper heat tube, and gives off heat to the outside world, condenses into liquid. Condensate in under the action of gravity, along the heat pipe wall returns to the heating period, and once again heated vaporization, cycling, continuous heat from one end to the other end. Because is phase change heat transfer, heat pipe heat resistance is very small,
Q: What iscalled cooler closed?Is used in cooling water temperature and adding vacuum pump work in the refrigeration system
Retrofit scheme is rod baffle heat exchanger instead of vertical bow plate heat exchanger, without changing the original shell heat exchanger, only change the heat exchanger tube core, is still the vertical installation. Shell side fluid adapted the aspirant, accessory equipment and pipe interface are the same. Heat exchange tube from d19mm x 1 mm brass tube replacement d19mm x 2 mm into boiler seamless steel tubes. Transformation technical agreement requirements, unit with full load, water temperature not less than 21 ℃, modified heater performance test data and calculated results are shown in table 2
Q: Thermal conductive materials used in electrical and electronic equipment that is the best?
Strongly recommend you to look all kinds of thermal conductive materials, our company bought their products to use on the LED product light, the more effect surpassed Japan letter. In general electric and electronic equipment need more potting glue, thermal conductivity of thermal conductivity is silica gel and thermal conductive silicone, silicone pad, thermal conductivity in the LED display with the thermal conductive double-sided tape also has a lot of places. What kind of material is best, or to the specific environment, right?
As a leading manufacturer, all Microtec products are fully assembled by our state of the art manufacturing facility prior to shipment and released only after extensive testing and inspection by our qualified technicians, maintaining the strictest quality control procedures.Our mission is to be a world supplier of Heat Transfer Products and Consumables. We are committed to the principal of satisfying customer and market demands, pursing scientific administration and superior quality by using the latest technology grounded in a thorough understanding of the end-user's needs.

1. Manufacturer Overview

Location Guangdong,China
Year Established 2007
Annual Output Value
Main Markets 7.69% North America
7.69% South America
7.69% Eastern Europe
7.69% Southeast Asia
7.69% Africa
7.69% Oceania
7.69% Eastern Asia
7.69% Western Europe
7.69% Central America
7.69% Northern Europe
7.69% Southern Europe
7.69% South Asia
Company Certifications ISO 9001:2008;SGS; CE

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a) Trade Capacity
Nearest Port Shenzhen,Guangzhou,Zhuhai
Export Percentage 81% - 90%
No.of Employees in Trade Department 11-20 People
Language Spoken: English, Chinese
b) Factory Information
Factory Size: 5,000-10,000 square meters
No. of Production Lines 6
Contract Manufacturing OEM Service Offered Design Service Offered Buyer Label Offered
Product Price Range Average

Send your message to us