COMPRESSION EMT CONNECTOR-STEEL,EMT Steel Compression Connector
- Loading Port:
- Ningbo
- Payment Terms:
- TT or LC
- Min Order Qty:
- 1000 pc
- Supply Capability:
- 300000 pc/month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
Description:
EMT Steel Compression Connector
Steel compression connectors are used to ground andsecure EMT raceways to boxes and enclosures. EMT steel connectors provide concrete tight connections when taped and properly secured with the included locknut, and are rated for electrical applications above 600 volts. Their heavy gauge steel construction maintains mechanical protection and solid grounding of the conduit to the designated electrical junction box or enclosure. Additionally, EMT compression connectors are pure steel and with zinc-plated surface for excellent corrosion protection.
Features:
Male hub threads-NPT
Available with insulated threat
Concretetight
Insulated throat connnector rated 90 degree
Materila/ Finish: Body and nut made from steel, Steel / Zinc plated
Application:
EMT compression connector: Joins steel EMT conduit to Electrical box and enclosure
•Connect & effectively bond EMT conduit to steel outlet boxes, load centers & other metal enclosures
•in concrete-tight applications when taped
•Body and locknut made from steel and with zinc-plated surface
•Reversible locknut designed to cut through protective coatings on boxes & enclosures
•UL standard for safety
•Application type : EMT
•Electrical Product Type : Standard Fitting
•Fitting type : Connector
•Indoor/Outdoor : Indoor/outdoor
•Paintable/Stainable : No
•Trade Size (in.) : [1/2"] [3/4"] [1"] [1-1/4"] [1-1/2"] [2"][2-1/2"] [3"] [4"]
Competitive Advantage:
+Quick Delivery: within 30 days for one 20ft container.
+Competitive Price
+ Good Quality: ISO/UL certificate approval
+Best Service: fast delivery, strong package, good price, timely and effective communication
+Powerful Solution: fast and effective solution to problem
- Q:5 air conditioning can be used 4 square cable
- You do not use the 9V power supply, a long time will burn the router.You'd better measure the original adapter voltage, if you want to extend the power cord, it is best to use a thick line of reliable connection, you can not start now, you can not start Depending on whether the extension line is too thin, causing the voltage drop too much.It is necessary to extend the front end of the adapter can extend the 220V power cord.
- Q:How much of the cable with the switch?
- Switch = (2-2.5) current three-phase current = P / 1.732 / 0.38 / 0.8 single-phase current = P / 0.22 / 0.8
- Q:25 square copper cable how much money one meter?
- 3000w electrical work at 220V voltage is about 13.6A (current = power divided by voltage). Copper core line of the working current is generally a square 4-6A. That is to say you use 3-4 square power cord more secure.
- Q:6 square cable up to how many air conditioning (1.5P)
- 7 kilowatts of electricity with what specifications of the wire if it is single-phase 220V, then 7 kilowatts of current is 7000 × 220V = 31.8A, check the electrical manual 4 square copper wire interception is 33A, to meet the requirements.
- Q:Does anyone know the "line buckle" classification (including shape / size / material / has been some commonly used size!) Line deduction is a hardware products! For daily necessities!
- In accordance with the relevant safety regulations, the power cable should not be parallel to the top of the thermal pipe laying, when can not be avoided, the interval distance should not be less than 1000mm, during which should also take effective insulation measures. Power cable and thermal pipe cross, the thermal pipe insulation layer, the separation distance should be not less than 500mm, no insulation layer should not be less than 1000mm, and in the cross with the insulation board to be protected, the length of the insulation board should not be less than d + 2000mm (d for the thermal pipe insulation layer diameter).
- Q:The difference between nylon balls and geese and ducks
- As long as the cable is thick enough, 20 meters of the basic loss can be ignored.
- Q:Can the main cable be aluminum cable? And explain why, thank you!
- Excretion training is the use of positive reinforcement, that is, a variety of food, toys, the best time to reward
- Q:3 by 16 cable is a few flat? How? That 5 by 16?
- Is the power directly out of the CPU power supply line or on this basis and added the extension line
- Q:How do I ask for cable prices? How many tons is one or more?
- As long as the line connected to the corresponding location, that is, audio cable audio and video cable, video cable can be used with the video line.
- Q:1000 kW 600 m cable to use much
- 1000kw ah that with three groups of 400-ping line should be no problem
1. Manufacturer Overview |
|
---|---|
Location | |
Year Established | |
Annual Output Value | |
Main Markets | |
Company Certifications |
2. Manufacturer Certificates |
|
---|---|
a) Certification Name | |
Range | |
Reference | |
Validity Period |
3. Manufacturer Capability |
|
---|---|
a)Trade Capacity | |
Nearest Port | |
Export Percentage | |
No.of Employees in Trade Department | |
Language Spoken: | |
b)Factory Information | |
Factory Size: | |
No. of Production Lines | |
Contract Manufacturing | |
Product Price Range |
Send your message to us
COMPRESSION EMT CONNECTOR-STEEL,EMT Steel Compression Connector
- Loading Port:
- Ningbo
- Payment Terms:
- TT or LC
- Min Order Qty:
- 1000 pc
- Supply Capability:
- 300000 pc/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches
Related keywords