Size: DN25-DN200
Nominal Pressure: PN10/PN16
Operation Temperature: ≤80°C
Suitable Medium: Water
2.Feature
CARX composite exhaust valve body for round barrel, including stainless steel ball valve body, valve stem and disc. This valve is installed in the pump outlet or send water distribution pipeline, set is used to eliminate the air in the tube, to improve the efficiency of the use of the pipeline and water pump, when once produced negative pressure tube, this rapid inhalation outside air valve, in order to prevent the pipeline damage due to negative pressure.
When tube began to water injection, the disc in the open position, a large number of exhaust, when the air line up, the full of water in the valve, floating ball up and drive the valve closed, stop the exhaust, when water tube is normal transportation, if there is a small amount of air within the valve to a degree, water levels fall in the valve, floating ball drops, the air is being exhausted from the holes. When the pump stops, the tube water empty or negative pressure in the tube, the plug head quickly open, inhalation of air, to ensure pipeline safety.
- Q: Where is the hydrant main valve?
- The fire hydrant generally has two sources, one is from the roof water tank, a water pump is from the housing, maintenance, should close the fire hydrant located on the riser inlet valve tube under the ring, generally located in the top and bottom, and then discharge, when the valve cannot be closed, the proposed closure of replenishment valve and the pressure stabilizing device of water tank, fire pump in manual state, drainage after maintenance. Watch out for fire.
- Q: In the fire drawing, what valve does the following valve represent?
- This is definitely the sprinkler system. It's a drain valve, a ready valve. You check it. I can't remember it. It has not been drained for a long time.
- Q: How can you replace the other valve when the main valve is not closed and no water is stopped?
- You really want to go to the big water to fix the valve and be prepared for the follow-up, just in case
- Q: Why is copper used in cryogenic valves?
- The rigidity of copper is better, and the friction parts are not easy to produce adhesion. The influence of temperature on copper is smaller than that of steel. Especially in the valve stem, there is also the important gear part, copper!
- Q: What does the "Z45T-16" valve mean?
- Z - gate valve4 - flange connection5 - Dark pole, stem non lifting (gate valve structure)T - copper alloy, valve sealing face code16 - pressure code, 1.6MPaMaterial code for grey cast iron valves of nominal pressure less than or equal to PN16 shall be omitted in model preparation.May refer to JB/T 308 valve model compilation method
- Q: What valve does the high pressure by-pass valve DN254 * 800 belong to?
- You want to ask the classification or valve DN254 mean?. The data you gave was incomplete. No answer.
- Q: What is a heavy body valve?
- To put it plainly is the question of weight... This is to the wall thickness and weight, specifically on what to use
- Q: How much is the 150LB of the valve?
- The valve according to the material is divided into cast iron valves, cast steel valves, stainless steel valves (201, 304, 316), chrome molybdenum steel, chromium molybdenum vanadium steel valves, valve, dual phase steel valves, plastic valves, non-standard customized valve material etc..
- Q: How do you calculate the flow of the valve?
- Valve flow calculation value is very vague, pipe pressure, back pressure, medium viscosity, medium temperature, valve structure, and so on, will affect the calculated value.
- Q: What is the diameter of a general pipe valve?
- In fact, the essence of the problem is the corresponding relationship between the nominal diameter and other dimensioning methods. Valves are generally marked with nominal diameter (DN***), such as DN150, DN100 and so on. There are many kinds of marking methods for pipes, such as outer diameter, inch inch, nominal diameter, etc.. Only when the other dimensioning is converted to nominal diameter, the valve and the pipe correspond to each other.