butterfly valve Doubly-eccentric butterfly valves
- Loading Port:
- China Main Port
- Payment Terms:
- TT OR LC
- Min Order Qty:
- -
- Supply Capability:
- -
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
Quick DetailsStandard or Nonstandard: Standard Structure: Gate Pressure: Medium Pressure
Power: Manual Material: Casting Temperature of Media: Medium Temperature
Media: Water Port Size: DN40mm-DN300 Place of Origin: China (Mainland)
Model Number: GF4 resilient gate valves: resilient seat flange
Packaging & DeliveryPackaging Detail: air plastic bag inside/wooden box outside
Delivery Detail: 15-60days
SpecificationsDIN3352 F4 resilient seat flange gate valves
1.s:DN40-DN300 ize
2.medium:water
3.standard:DIN
4.certificate:ISO9001 CE
resilient gate valves
1.size:DN40-DN300
2.medium:water
3.certificate:ISO9001 CE
4.standard:DIN
available medium:water
working temperature:≤80oC
flange dimensions:DIN2501
- Q: What's the use of fire butterfly valve?
- You should ask the signal butterfly valve, butterfly valve in the fire signal system which is a monitoring alarm signal, its purpose is to ensure that the valve has been opened in the daily state, to prevent misuse operation was closed, thus affecting when accidental fire extinguishing. Therefore, it is necessary to set up the signal valve!
- Q: What does "D341X-16Q" mean?What do D341-16Q letters and numbers mean for butterfly valves?
- D - valve type code: Butterfly valve;3 - valve drive mode code: worm gear;4 - valve connection form code: flange;1 - valve structure type code: vertical plate type;X - seat sealing surface or lining material code: rubber;16 - nominal pressure value: PN1.6MPa;Q - body material code: QT400 - 15.
- Q: 16 inches below the choice of electromagnetic valve can be the same, it turned out to be DN200 election 1/4, and now there are DN350 can also use this? With it, limiter, pressure relief valve, locator model will change?
- The valve (including the valve, butterfly valve, etc.) are equipped with pneumatic actuators are standard (including restrictor valve positioner of the electromagnetic valve is connected with the installation.) is the international standard NAMUR standards, in the standard of inside electromagnetic valve is G1/4, of course, this is the solenoid valve installation in the NAMUR interface of the driver on the situation, if the solenoid valve is not installed on the drive, but through the trachea installed in a few meters away, it would have to choose a larger size, how to choose? Depends on the switching speed of the valve requirements, such as drive gas consumption is 2L, need to open in 1S, the electromagnetic the valve requires the flow of 120L/min, plus the line loss and acceleration, 500L/min is enough.
- Q: Transformer butterfly valve and pressure relief valve difference
- I don't know. Let's have a Baidu! Baidu is powerful.
- Q: 1st where is my zone valve? I have an old Burnham gas baseboard heater2nd What do I do?My last resort is calling a proffesional.
- First: Wat make you tinkling that the zone is bad? Every zone cooperate with 2 other essential parts: thermostat and power supply, In 90% of my carea, people firs go with their thinking to zone, but only 10% was realy zone. The first thing to check is termostat and power. you could do this very simply by removing termostat wire and tickling them together several times, if they have spark, than the most prabably is just thermostat broken
- Q: The difference between the electric control valve and the electric butterfly valve, respectively, the application situation
- Butterfly valve switching speed, fluid resistance is small, but the flow control is not good, suitable for only fast opening and closing occasions. Control valve switching speed is relatively slow, fluid resistance, but the flow control of the linear good, suitable for flow control requirements of the occasion.
- Q: Fire, the signal butterfly valve flange connection or welding?
- Grooved flange joint, welded flange connection! Wire bonding. Wire to flange connection! In addition, you can choose the groove type signal butterfly valve!
- Q: How does the pneumatic butterfly valve control the angle of opening?
- This is really not good, control seems to be pneumatic defects, can only rely on the feeling
- Q: My bike has now 6200 miles on the odometer. The manual says that a valve adjustment should be performed every 6000 miles. But the bike runs fine. Can I just have the valve checked or should I have them adjusted even though the bike is fine? What will happen if I just keep riding it?
- In reality, lots of bikes go their entire lives without a valve adjustment. In my opinion that is a great way to ruin a bike though. They have a maintence schedule for a reason. If a valve isn't seating, it can hurt performance and the valve will not be able to transfer heat to the head. That can burn a valve and cause detonation. You have to check valves to adjust them, and the labor for just checking will be nearly the same or identical to doing the adjustments. I do all my own wrenching, so money isn't really an issue, but if I were you, I would just bite the bullet and take it in.
- Q: D what's the meaning of "one 71x one 1 butterfly"?
- According to the provisions of the JB/T 308-2004 valve type programming method:D== butterfly valve7== clip typeLinetype in 1==X== sealing surface material: Rubber-1== pressure rating: 1.0MPa
Send your message to us
butterfly valve Doubly-eccentric butterfly valves
- Loading Port:
- China Main Port
- Payment Terms:
- TT OR LC
- Min Order Qty:
- -
- Supply Capability:
- -
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches
Related keywords