BM-LS type load cell has peculiar structure of both ends supporting, center forced. This structure enable the load cell to be high accuracy, high reliability in measuring.Force is transferred by pressure head and steel ball which can automatically recover and correct core. The elastic body is made of alloy steel. Cross-range force and impulsive force can be well resisted. Sealed hermetically with damp-proof material, the load cell can work properly in adverse circumstances and has protection grade specified as IP68. It is used to be explosive dangerous circumstance, the explosion-proof symbol is Exia II CT6Ga; ExiaD20T85.It has good compatibility and can be conveniently installed. Suitable for truck scale, track scale, hopper scale, and other special scales for weighing and force measurement. It has received the NTEP certificate.
Our company also produces strain gauge, weighing indicator and other scale such as truck scale, platform scale and hopper scale.
- Q:Working principle of pressure sensor in constant pressure water supply system
- The pressure sensor is a diffusion Wheatstone bridge on silicon substrate, voltage resistance effect of bridge wall resistance value changes and generates a differential voltage signal. The signal is transformed into a standard 4~20mA/0~5VDC/0~10VDC signal by a special amplifier and then converted by voltage and current.
- Q:The intake pressure sensor is broken. What are the symptoms of the car?
- Basically no symptoms, the intake pressure sensor is mainly used in the plateau when the role, and generally plain areas do not work
- Q:Difference between pressure sensor and pressure sensor
- Difference:1, measurement parameters are different: differential pressure sensor to measure the relative pressure, that is, the pressure difference between the two parts. Pressure sensors measure absolute pressure.2. The interface is different. The pressure sensor has two input ports, which are used to connect two measuring points. The pressure sensor has only one connecting pipe orifice.
- Q:How does the PLC collect the pressure measured by the pressure sensor and how to display the pressure curve through the touch screen?
- No matter what brand of PLC switch is unable to complete the pressure collection, use an analog acquisition module, and then do analog conversion within the PLC. To display the pressure curve on the touch screen, communicate the PLC with the touch screen, and then touch the screen with a curve control.
- Q:What are the differences between the four components of the pressure transmitter, the pressure switch, the pressure sensor and the pressure relay?
- The pressure sensor is measured and converted to pressure signal, the pressure transmitter includes a pressure sensor and transmitter, pressure switch, pressure to a certain extent open or disconnected, the pressure relay of similar power relay, only one power, one is the pressure to a certain value of work
- Q:Is the pressure sensor I can only produce 0-5mV signal, I want to enlarge it, but when I connect the pressure sensor and the amplifier, not to pressure, there are large fluctuations in output, when I give the pressure, but the signal can magnify the volatility is quite large, how to solve?
- The signal from the sensor out of the first stage you into the follower, why the first to follow, I suggest you take the first withdrawal. Don't follow the signal of pressure sensor out of the long line, you are using a wire shielding line? No shielding line you want to use the shielded wire, shielding wire shielding layer one end is connected with the DC power amplifier. You use level two, electric block 20K/10K, each 22 times. If I said it is not feasible, changed. If not, I think the amplifier should also be performed, increase the zoom resistance ratio increase, the resistance of 220K and 10K with a reduced resistance. An amplifier.
- Q:I have a 20000N range pull pressure sensor and an 2000N range amplifier. I think the two are connected. My actual requirement is 2000N, and the 18000N behind the sensor is not required.In the process of calibration, problems were found. First of all, I switched zero. When I applied the force of 500N, the value on the computer was 35N, and then I switched it up. When I was transferred to the value of 98N, I couldn't tune it any more, no matter how the potentiometer turned.Please help me explain the reason for this phenomenon, thank you.
- You can use the 4000N sensor at most, and you can use the 20000N sensor
- Q:They recommend XYPT5000 series, have not used before, useful in this series of pressure transmitter friend?I mainly used to measure the vacuum, choose -100kpa-0 or 0-100kpa absolute pressure sensor of pressure type can, need to pay attention to what the selection process used to you enlighten me!
- -100kpa-0 negative pressure sensor and 0-100kpa absolute pressure sensor measure vacuum only reference starting point is not the same, if the same accuracy, the same type of sensor, the same effect. This sensor has not been used before, but the situation
- Q:For example, by using a positive pressure sensor, the analog voltage output is 1-5V. What is the analog current? I need to find an analog current of 4-20mA. What is the corresponding voltage?
- This can't be compared. If the sensor output is current, it can only guarantee that the current value is linear to the measured value, and that the voltage will vary with the load, and so will the voltage product.
- Q:Can the MITSUBISHI FX2N series PLC pressure sensors be connected directly? I need to measure the weight of paper packaged milk products on the production line. What type of pressure sensors should be used? Can take down the wiring diagram?
- You should not use, but the pressure sensor, weighing sensor, not directly into the PLC, previously used, that is used in transducer matching, and then output the analog signal into PLC, so you need to have a grand pan analog point.The specific model determines the range and accuracy of the sensor according to the weight you actually measured
1. Manufacturer Overview |
|
---|---|
Location | |
Year Established | |
Annual Output Value | |
Main Markets | |
Company Certifications |
2. Manufacturer Certificates |
|
---|---|
a) Certification Name | |
Range | |
Reference | |
Validity Period |
3. Manufacturer Capability |
|
---|---|
a)Trade Capacity | |
Nearest Port | |
Export Percentage | |
No.of Employees in Trade Department | |
Language Spoken: | |
b)Factory Information | |
Factory Size: | |
No. of Production Lines | |
Contract Manufacturing | |
Product Price Range |
Send your message to us
BM-LS Type Kuborta Shape Analog Load Cell
- Loading Port:
- Qingdao
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 10 pc
- Supply Capability:
- 500 pc/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches
Related keywords