Battery Solar Wind Power System High Temperature 2V 500AH
- Loading Port:
- Shanghai
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 10 pc
- Supply Capability:
- 1000 pc/month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
Range summary
313K Series batteries are designed for high-temperature environment and new energy such as wind energy, photovoltaic energy storage system. With high temperature resistance, long life, safety and reliability characteristics, 313K series is widely used in telecommunications, electric power, energy storage, and it ideal for cycle or hybrid system in harsh, high temperature environment.
The 313K series batteries are ensured the quality with NARADA's QA system according to the ISO9001&ISO14001 standard.
Features and Benefits
1. Patented anti-corrosion grid technology
2. Optimized active material for high temperature conditions
3. Unique high temperature case material with HDT in excess of 124oC
4. Increased internal compression for improved cycling endurance
5. Oxygen catalyst to reduce float currents and extend cycling capability
6. Containers & lids UL94 V-0 rated
7. Advanced negative plate protection system
8. Wide operating temperature range:-40oC to +80oC
9. Normal operating temperature is 35oC
10. Excellent deep cycling capability systems
11. Suitable for continuous operation at temperatures in excess of 35oC
12. Reduced system operating costs 25% electricity power saving
13. Up to 100% air conditioner maintenance saving
14. Up to 100% condensing agent saving
15. 30% CO2 gas emission reduce
16. Less than 1 year payback period depend on environment
Compliant standards
1. IEC60896-21/22
2. IEC61427
3. BS6290 part 4
4. Telcordia SR4228
5. Eurobat guide
6. UL
7. Manufactured under system ISO9001(TUV) and ISO14001
Battery installation compliant with:
1. EN 50272-2 or local equivalents
Main applications
1. Hybrid telecom remote base stations
2. Renewable energy wind & solar sites
3. Grid frequency leveling systems
4. All back-up applications where grid reliability is poor
5. All extreme environment off-grid
Products characteristics:
1. Recommended float charge voltage for 2V battery: 2.24Vpc at 35oC(95oF), 2.27Vpc at 25oC(77oF)
2. Self discharge rate :<5% per month at 35oC(95oF)
3. Design life: 15 years at 35oC (95oF)
4. VRLA high temperature battery, no water addition required
Technical Data:
- Q: How to repair the battery?
- Pry open the adhesive or heat-sealed battery cover, reveal the maintenance-free battery rubber exhaust valve, carefully remove the exhaust valve, save, observe the battery internal situation. Add 0.1% to 0.5% of the electrolyte to the battery, just to the battery above the flow of electrolyte. At the same time, check whether the black impurities, if there are obvious black turbid impurities, indicating that the battery plate has been significantly softened, the possibility of battery repair is relatively small. If there is no black muddy impurities, need to wait 4 hours later, the water fully into the battery. If it is only because the deactivation time is long and cause the battery capacity to decline, do not need to carry out this step operation, should go directly to step 3 pre-charge.
- Q: How is the capacity of the battery defined?
- The capacity of the battery unit is AH (safety) is the product of current and time.
- Q: What are the technical parameters of the battery?
- Usually the capacity of the power supply is expressed by kV · A or kW. However, as a power supply VRLA battery, the use of security (A · h) that its capacity is more accurate.
- Q: What battery does the van use?
- The most obvious feature of lead-acid batteries is the top of the plastic cover can be unscrewed, there are ventilation holes above. These fillers are used to fill pure water, check the electrolyte and the use of exhaust gas. In theory, lead-acid batteries need to check the density of each electrolyte and the level of liquid, if there is a need to add distilled water. But with the upgrading of battery manufacturing technology, lead-acid battery development for the lead-acid maintenance-free batteries and colloidal maintenance-free batteries, lead-acid batteries do not need to add electrolyte or distilled water. Mainly the use of positive electrode to produce oxygen can be absorbed in the negative oxygen cycle, to prevent water reduction. Lead-acid water batteries are mostly used in tractors, tricycles, car start, etc., and maintenance-free lead-acid battery wider range of applications, including uninterruptible power supply, electric vehicle power, electric bicycle batteries. Lead-acid batteries according to the application needs to be divided into constant current discharge (such as uninterruptible power supply) and instantaneous discharge (such as car to start the battery).
- Q: What are the advantages of maintenance-free batteries?
- Maintenance-free battery using lead-calcium alloy grille, the amount of water generated when charging less water evaporation is low, with the shell with a sealed structure, the release of sulfuric acid gas is also very little, so with the above advantages.
- Q: What is the meaning of the battery above 12v65Ah?
- Voltage 12V, current 65AH, that is the capacity of 65A. (A is the unit of current. H is the time unit)
- Q: How should the battery be well maintained?
- Electrolyte density This is to evaluate whether the battery charge is normal, whether the aging of the important parameters, the use of density meter or electrolyte density tester can be measured. If the electrolyte density is too small, you need to charge. And the electrolyte concentration is too thick or too thin to a certain extent, it means that such as the occurrence of plate vulcanization, short circuit or overcharge phenomenon, this time on the need for maintenance.
- Q: What kind of battery is divided into?
- Ordinary battery: ordinary battery plate is composed of lead and lead oxide, the electrolyte is sulfuric acid aqueous solution. Its main advantage is the voltage stability, the price is cheap.
- Q: What is a maintenanceable battery?
- This is relative to a maintenance-free battery. Maintenance of the battery needs to be supplemented with electrolyte to ensure work, while maintenance-free is not required.
- Q: How does battery activation work?
- Always keep the battery surface clean. Found that the surface of dust and acid, it should be timely wipe, wipe can be wiped with soda water wipes wipe again, after rinse with water.
Send your message to us